Influence of artificial intelligence-based registration and occlusal collision correction on the accuracy of occlusal contacts captured at maximum intercuspal position using an intraoral scanner: A clinical comparative study
The Journal of Prosthetic Dentistry · 2026
DOI: 10.1016/j.prosdent.2025.10.028 ↗Kurz gefasst
Vergleichsstudie in der Zeitschrift The Journal of Prosthetic Dentistry, 2026. Verfasst von Panagiotis Ntovas und 4 weiteren Autor:innen. Beteiligte Einrichtung: Adjunct Faculty, Department of Prosthodontics, School of Dental Medicine, Tufts University, Boston, Mass.; External coworker, Division of Fixed Prost…. Hauptthemen laut MEDLINE: Artificial Intelligence, Dental Occlusion. Die Arbeit wurde bisher 5-mal zitiert (Crossref) und nennt 52 Literaturangaben.
Abstract (Originalsprache)
STATEMENT OF PROBLEM: Artificial intelligence (AI)-driven programs and occlusal collision correction algorithms have been proposed to improve the accuracy of articulating intraoral scans in maximum intercuspal position (MIP). However, the effect of each post-processing method on the accuracy of the MIP relationship remains unclear. PURPOSE: The purpose of this clinical comparative study was to assess the influence of occlusal collision correction method and AI-driven registration on the accuracy of occlusal contacts recorded in MIP using an intraoral scanner (IOS). MATERIAL AND METHODS: Occlusal contacts in MIP were recorded using articulating film in 46 participants and digitized using maxillary and mandibular scans captured with an IOS (TRIOS 4; 3Shape A/S). For each participant, a bilateral virtual occlusal record was generated in MIP. The scans were duplicated and assigned to 3 groups: non-articulated (NA), IOS-non-corrected (INC), and IOS-corrected (IC). Using a computer-aided design (CAD) software program (Elefsina 3.2; exocad GmbH) the INC and the IC scans were post-processed implementing 3 different methods: Cast trimming (CT) and increasing vertical dimension either by moving the jaws apart (IVDM) or by opening articulator's incisal pin (IVDA). An AI-driven software program (Bite-Finder) was also used to post-process both the INC and IC scans. The same AI program was also used to articulate the NA scans in MIP, generating the NA-AI group. Occlusal contact accuracy was assessed by 2 calibrated examiners, using the digitized articulating film contacts as reference. One-way ANOVA was used to examine if average True positive contacts and false positive contacts were different across the post-processing methods (P
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Autor:innen und Institutionen
- Adjunct Faculty, Department of Prosthodontics, School of Dental Medicine, Tufts University, Boston, Mass.; External coworker, Division of Fixed Prosthodontics and Biomaterials, University Clinics for Dental Medicine, Un…
- Associate Professor, Department of Prosthodontics, School of Dental Medicine, Tufts University, Boston, Mass.
- Associate Professor Clinical Research and Biostatistics, Eastman Institute of Oral Health, University of Rochester Medical Center, Rochester, NY, United States.
- Professor, Department of Prosthodontics, University Hospital of Freiburg, Freiburg, Germany. Private practice, The Face Dental Group, Boston, Mass.
- Affiliate Assistant Professor, Graduate Prosthodontics, Department of Restorative Dentistry, School of Dentistry, University of Washington, Seattle, Wash.; Faculty and Director of Research and Digital Dentistry, Kois Ce…
Zitieren
APA
Ntovas, P., Vazouras, K., Barmak, A. B., Att, W., & Revilla-León, M. (2026). Influence of artificial intelligence-based registration and occlusal collision correction on the accuracy of occlusal contacts captured at maximum intercuspal position using an intraoral scanner: A clinical comparative study. The Journal of Prosthetic Dentistry. https://doi.org/10.1016/j.prosdent.2025.10.028
Vancouver
Ntovas P, Vazouras K, Barmak AB, Att W, Revilla-León M. Influence of artificial intelligence-based registration and occlusal collision correction on the accuracy of occlusal contacts captured at maximum intercuspal position using an intraoral scanner: A clinical comparative study. The Journal of Prosthetic Dentistry. 2026. doi:10.1016/j.prosdent.2025.10.028
BibTeX
@article{Ntovas2026,
author = {Ntovas, Panagiotis and Vazouras, Konstantinos and Barmak, Abdul B and Att, Wael and Revilla-León, Marta},
title = {Influence of artificial intelligence-based registration and occlusal collision correction on the accuracy of occlusal contacts captured at maximum intercuspal position using an intraoral scanner: A clinical comparative study},
journal = {The Journal of Prosthetic Dentistry},
year = {2026},
doi = {10.1016/j.prosdent.2025.10.028}
}