EUVIMEDScopri EUVIMED
Open access · CC BY-NC 4.0

Optic Nerve Sheath Diameter: Which Axis Should Be Measured?

Jakob Pansell iD, Tina Thomsson, Emelie Eng, Andreas Wallin, Mohammad Hirzallah

Journal of Neuroimaging · 2025

DOI: 10.1111/jon.70076 ↗

At a glance

Journal article in Journal of Neuroimaging, 2025. Written by Jakob Pansell and 4 co-authors. Institution: The Department of Clinical Neuroscience, Karolinska Institutet, Stockholm, Sweden. Major MEDLINE topics: Optic Nerve, Intracranial Hypertension. Cited 1 times so far (Crossref); 19 references. The full text is freely available (open access, CC BY-NC 4.0). Funded by: Stockholm Region Innovations Fund.

AbstractSubjectsDati bibliograficiCiteRelated studies

Abstract (original language)

Background and purpose Optic nerve sheath diameter (ONSD) measured by point‐of‐care ultrasound (POCUS) is a commonly used non‐invasive estimate of intracranial pressure (ICP). However, methodological variations limit standardization of this promising technique. Different imaging axes are identified as one such source of ONSD POCUS methodological variation. This study aimed to evaluate the agreement and diagnostic accuracy for elevated ICP between transverse and sagittal ONSD measurements.

Methods

We conducted a post‐hoc analysis of 213 intensive care patients from three prior studies. ONSD was measured in both transverse and sagittal planes, externally (ONSDext) and internally (ONSDint) of the dura mater. Agreement was assessed using Lin's concordance correlation coefficient (CCC). Diagnostic accuracy for detecting ICP ≥20 mmHg was evaluated using area under the receiver operator characteristics curve (AUROC) analyses in a subset of 139 patients.

Results

Sagittal ONSD was significantly larger than transverse ONSD (median difference 0.2 mm, p

Subjects

MeSH terms (MEDLINE)

Optic NerveIntracranial HypertensionHumansFemaleMaleMiddle AgedUltrasonographyAdultIntracranial PressureAgedReproducibility of ResultsPoint-of-Care Systems

Author keywords

cerebral edemacritical careintensive careintracranial pressureoptic nerve sheath diametersonographyultrasound

Authors and institutions

  • The Department of Clinical Neuroscience, Karolinska Institutet, Stockholm, Sweden.
  • The Department of Anesthesia and Intensive Care Medicine, Karolinska University Hospital, Stockholm, Sweden.
  • The Department of Neurobiology, Care Sciences and Society, Division of Physiotherapy, Karolinska Institutet, Huddinge, Sweden.
  • Women's Health and Allied Health Professionals Theme, Medical Unit Allied Health Professionals, Karolinska University Hospital, Stockholm, Sweden.
  • Departments of Neurology and Neurosurgery, Baylor College of Medicine, Houston, Texas, USA.
  • Center for Space Medicine, Baylor College of Medicine, Houston, Texas, USA.

ORCID profiles: Jakob Pansell

Funding

  • Stockholm Region Innovations Fund

Cite

APA

Pansell, J., Thomsson, T., Eng, E., Wallin, A., & Hirzallah, M. (2025). Optic Nerve Sheath Diameter: Which Axis Should Be Measured?. Journal of Neuroimaging. https://doi.org/10.1111/jon.70076

Vancouver

Pansell J, Thomsson T, Eng E, Wallin A, Hirzallah M. Optic Nerve Sheath Diameter: Which Axis Should Be Measured?. Journal of Neuroimaging. 2025. doi:10.1111/jon.70076

BibTeX
@article{Pansell2025,
  author = {Pansell, Jakob and Thomsson, Tina and Eng, Emelie and Wallin, Andreas and Hirzallah, Mohammad},
  title = {Optic Nerve Sheath Diameter: Which Axis Should Be Measured?},
  journal = {Journal of Neuroimaging},
  year = {2025},
  doi = {10.1111/jon.70076}
}
Start for free →