EUVIMEDPoznaj EUVIMED
Crossref

Aspiration Catheter Design Impacts Combined Approach Mechanical Thrombectomy in Anterior Circulation Large Vessel Stroke

Josep Puig iD, Sebastià Remollo, Isabel Rodríguez-Caamaño, Carlos Castaño, Marc Comas-Cufí, Mariano Werner, Guillem Dolz, Jordi Blasco, Luis SanRoman, Juan Manuel Sanchis, Fernando Aparici-Robles, Eva González and 19 more

Journal of Neuroimaging · 2025

DOI: 10.1111/jon.70046 ↗

At a glance

Journal article in Journal of Neuroimaging, 2025. Written by Josep Puig and 30 co-authors. Institution: Radiology Department CDI, Hospital Clinic of Barcelona and IDIBAPS, Barcelona, Spain. Major MEDLINE topics: Thrombectomy, Catheters, Stroke. 30 references.

AbstraktSubjectsDane bibliograficzneCiteRelated studies

Abstract (original language)

Background and Purpose Large‐bore aspiration catheters (LBACs) are used for thrombectomy in large vessel occlusion (LVO), either as a standalone direct aspiration first‐pass technique or combined with a stent retriever (ASR). LBAC design may influence ASR thrombectomy efficacy. We compared the safety and performance of the novel MIVI Q segmental catheter with the well‐established SOFIA aspiration device in ASR thrombectomy.

Methods

We analyzed data from the Registry cOmbined vS SinglE Thrombectomy TechnIques registry of consecutive patients with anterior circulation LVO and compared the outcomes of those treated with first‐line ASR thrombectomy using Q (Q5 or Q6) or SOFIA (5F or 6F Plus) catheters. Demographic, clinical, angiographic, and clinical outcome data (24‐h National Institute of Health Stroke Scale [NIHSS] and modified Rankin Scale score at 3 months) were compared.

Results

Of the 853 patients, 155 (18.2%) were treated with MIVI Q and 698 (81.8%) with SOFIA catheters. After adjusting for age, sex, NIHSS score at baseline, tPA use, site occlusion, anesthesia type, and diameter and length of SR, the MIVI Q group was comparable to the SOFIA group in terms of first‐pass effect or successful final recanalization and safety. However, the MIVI Q group had a shorter mechanical thrombectomy time (20 [10–45] min vs. 33 [20–51] min; odds ratio [OR] = 7.4, 95% confidence interval [CI]: 1.1–14; p = 0.021) and a lower rate of symptomatic intracerebral hemorrhage (3.3% vs. 8.8%; OR = 3.59, 95% CI: 1.45–10.9; p = 0.011).

Conclusions

In ASR neurothrombectomy, SOFIA aspiration catheters were not superior to MIVI Q in achieving successful and complete first‐passage recanalization; however, MIVI Q had shorter procedural times and a lower rate of symptomatic intracranial hemorrhage.

Subjects

MeSH terms (MEDLINE)

ThrombectomyCathetersStrokeHumansMaleFemaleAgedEquipment DesignTreatment OutcomeRegistriesMiddle AgedSuctionAged, 80 and over

Author keywords

aspirationocclusionoutcomestrokethrombectomy

Authors and institutions

  • Radiology Department CDI, Hospital Clinic of Barcelona and IDIBAPS, Barcelona, Spain.
  • Department of Interventional Neuroradiology, Hospital Universitari Germans Trias i Pujol, Badalona, Spain.
  • Department of Computer Science, Applied Mathematics and Statistics, University of Girona, Girona, Spain.
  • Neurointerventional Department CDI, Hospital Clinic de Barcelona, Barcelona, Spain.
  • Department of Interventional Radiology, Hospital Universitario La Fe, Valencia, Spain.
  • Department of Interventional Neuroradiology, Radiology, Hospital Cruces, Bilbao, Spain.

ORCID profiles: Josep Puig

Cite

APA

Puig, J., Remollo, S., Rodríguez-Caamaño, I., Castaño, C., Comas-Cufí, M., Werner, M., Dolz, G., Blasco, J., SanRoman, L., Sanchis, J. M., Aparici-Robles, F., González, E., Fondevila, J., Vega, P., Murias, E., Jiménez, E., Oteros, R., López-Frias, A., Moreu, M., …, & ROSSETTI Group (2025). Aspiration Catheter Design Impacts Combined Approach Mechanical Thrombectomy in Anterior Circulation Large Vessel Stroke. Journal of Neuroimaging. https://doi.org/10.1111/jon.70046

Vancouver

Puig J, Remollo S, Rodríguez-Caamaño I, Castaño C, Comas-Cufí M, Werner M, et al. Aspiration Catheter Design Impacts Combined Approach Mechanical Thrombectomy in Anterior Circulation Large Vessel Stroke. Journal of Neuroimaging. 2025. doi:10.1111/jon.70046

BibTeX
@article{Puig2025,
  author = {Puig, Josep and Remollo, Sebastià and Rodríguez-Caamaño, Isabel and Castaño, Carlos and Comas-Cufí, Marc and Werner, Mariano and Dolz, Guillem and Blasco, Jordi and SanRoman, Luis and Sanchis, Juan Manuel and Aparici-Robles, Fernando and González, Eva and Fondevila, Jon and Vega, Pedro and Murias, Eduardo and Jiménez, Elvira and Oteros, Rafael and López-Frias, Alfonso and Moreu, Manuel and Bashir, Saima and Silva, Yolanda and Ripoll, Enric and Martínez-Fernández, Javier and Aguilar, Yeray and Méndez, José and Sánchez, Fernando and de Paco, Gonzalo and Flores, Alan and Llibre, Juan Carlos and Brinjikji, Waleed and ROSSETTI Group, ROSSETTI Group},
  title = {Aspiration Catheter Design Impacts Combined Approach Mechanical Thrombectomy in Anterior Circulation Large Vessel Stroke},
  journal = {Journal of Neuroimaging},
  year = {2025},
  doi = {10.1111/jon.70046}
}
Start for free →