Automation of ultrasonographic optic nerve sheath diameter measurement using convolutional neural networks
Journal of Neuroimaging · 2023
DOI: 10.1111/jon.13163 ↗At a glance
Journal article in Journal of Neuroimaging, 2023. Written by Mohammad I Hirzallah and 3 co-authors. Institution: Departments of Neurology and Neurosurgery, Baylor College of Medicine, Houston, Texas, USA. Major MEDLINE topics: Intracranial Hypertension, Brain Injuries. Cited 8 times so far (Crossref); 33 references.
Abstract (original language)
Background and purpose Ultrasonographic optic nerve sheath (ONS) diameter is a noninvasive intracranial pressure (ICP) surrogate. ICP is monitored invasively in specialized intensive care units. Noninvasive ICP monitoring is important in less specialized settings. However, noninvasive ICP monitoring using ONS diameter (ONSD) is limited by the need for experts to obtain and perform measurements. We aim to automate ONSD measurements using a deep convolutional neural network (CNN) with a novel masking technique.
Methods
We trained a CNN to reproduce masks that mark the ONS. The edges of the mask are defined by an expert. Eight models were trained with 1000 epochs per model. The Dice‐similarity‐coefficient‐weighted averaged outputs of the eight models yielded the final predicted mask. Eight hundred and seventy‐three images were obtained from 52 transorbital cine‐ultrasonography sessions, performed on 46 patients with brain injuries. Eight hundred and fourteen images from 48 scanning sessions were used for training and validation and 59 images from four sessions for testing. Bland‐Altman and Pearson linear correlation analyses were used to evaluate the agreement between CNN and expert measurements.
Results
Expert ONSD measurements and CNN‐derived ONSD estimates had strong agreement ( r = 0.7, p < .0001). The expert mean ONSD (standard deviation) is 5.27 mm (0.43) compared to CNN mean estimate of 5.46 mm (0.37). Mean difference (95% confidence interval, p value) is 0.19 mm (0.10‐0.27 mm, p = .0011), and root mean square error is 0.27 mm.
Conclusion
A CNN can learn ONSD measurement using masking without image segmentation or landmark detection.
Subjects
MeSH terms (MEDLINE)
Author keywords
Authors and institutions
- Departments of Neurology and Neurosurgery, Baylor College of Medicine, Houston, Texas, USA.
- Baylor College of Medicine, Center for Space Medicine, Houston, Texas, USA.
- San Ramon, California, USA.
- Department of Electrical and Computer Engineering, University of Pittsburgh, Pittsburgh, Pennsylvania, USA.
- Oakland, California, USA.
ORCID profiles: Mohammad I Hirzallah
Cite
APA
Hirzallah, M. I., Bose, S., Hu, J., & Maltz, J. S. (2023). Automation of ultrasonographic optic nerve sheath diameter measurement using convolutional neural networks. Journal of Neuroimaging. https://doi.org/10.1111/jon.13163
Vancouver
Hirzallah MI, Bose S, Hu J, Maltz JS. Automation of ultrasonographic optic nerve sheath diameter measurement using convolutional neural networks. Journal of Neuroimaging. 2023. doi:10.1111/jon.13163
BibTeX
@article{Hirzallah2023,
author = {Hirzallah, Mohammad I and Bose, Supratik and Hu, Jingtong and Maltz, Jonathan S},
title = {Automation of ultrasonographic optic nerve sheath diameter measurement using convolutional neural networks},
journal = {Journal of Neuroimaging},
year = {2023},
doi = {10.1111/jon.13163}
}
EUVIMED