Anatomical targeting for electrode localization in subthalamic nucleus deep brain stimulation: A comparative study

Thomas Tonroe iD, Hugh McDermott, Patrick Pearce iD, Nicola Acevedo, Wesley Thevathasan, San San Xu, Kristian Bulluss, Thushara Perera

Journal of Neuroimaging · 2023

DOI: 10.1111/jon.13133 ↗

At a glance

Journal article in Journal of Neuroimaging, 2023. Written by Thomas Tonroe and 7 co-authors. Institution: Bionics Institute, East Melbourne, Victoria, Australia. Major MEDLINE topics: Subthalamic Nucleus, Deep Brain Stimulation, Parkinson Disease. Cited 5 times so far (Crossref); 30 references. The full text is freely available (open access, CC BY 4.0). Funded by: Colonial Foundation, St Vincent's Hospital Melbourne, National Health and Medical Research Council.

RésuméSubjectsRéférences bibliographiquesCiteRelated studies

Abstract (original language)

Background and Purpose In deep brain stimulation (DBS), accurate electrode placement is essential for optimizing patient outcomes. Localizing electrodes enables insight into therapeutic outcomes and development of metrics for use in clinical trials. Methods of defining anatomical targets have been described with varying accuracy and objectivity. To assess variability in anatomical targeting, we compare four methods of defining an appropriate target for DBS of the subthalamic nucleus for Parkinson's disease.

Methods

The methods compared are direct visualization, red nucleus‐based indirect targeting, mid‐commissural point‐based indirect targeting, and automated template‐based targeting. This study assessed 226 hemispheres in 113 DBS recipients (39 females, 73 males, 62.2 ± 7.7 years). We utilized the electrode placement error (the Euclidean distance between the defined target and closest DBS electrode) as a metric for comparative analysis. Pairwise differences in electrode placement error across the four methods were compared using the Kruskal‐Wallis H ‐test and Wilcoxon signed‐rank tests.

Results

Interquartile ranges of the differences in electrode placement error spanned 1.18‐1.56 mm. A Kruskal‐Wallis H ‐test reported a statistically significant difference in the median of at least two groups ( H (5) = 41.052, p < .001). Wilcoxon signed‐rank tests reported statistically significant difference in two comparisons: direct visualization versus red nucleus‐based indirect, and direct visualization versus automated template‐based methods ( T < 9215, p < .001).

Conclusions

All methods were similarly discordant in their relative accuracy, despite having significant technical differences in their application. The differing protocols and technical aspects of each method, however, have the implication that one may be more practical depending on the clinical or research application at hand.

Subjects

MeSH terms (MEDLINE)

Subthalamic NucleusDeep Brain StimulationParkinson DiseaseMaleFemaleHumansElectrodesNeurosurgical ProceduresMagnetic Resonance Imaging

Author keywords

Parkinson's diseaseanatomical targetingautomationdeep brain stimulationelectrode localizationneuroimagingsubthalamic nucleus

Authors and institutions

  • Bionics Institute, East Melbourne, Victoria, Australia.
  • School of Engineering, RMIT University, Melbourne, Victoria, Australia.
  • DBS Technologies Pty Ltd, East Melbourne, Victoria, Australia.
  • Medical Bionics Department, The University of Melbourne, East Melbourne, Victoria, Australia.
  • Department of Neurosurgery, St Vincent's Hospital Melbourne, Fitzroy, Victoria, Australia.
  • Centre for Mental Health, Swinburne University of Technology, Melbourne, Victoria, Australia.

ORCID profiles: Thomas Tonroe, Patrick Pearce

Funding

  • Colonial Foundation
  • St Vincent's Hospital Melbourne
  • National Health and Medical Research Council
  • State Government of Victoria
  • RMIT University
  • Lions Clubs International Foundation

Cite

APA

Tonroe, T., McDermott, H., Pearce, P., Acevedo, N., Thevathasan, W., Xu, S. S., Bulluss, K., & Perera, T. (2023). Anatomical targeting for electrode localization in subthalamic nucleus deep brain stimulation: A comparative study. Journal of Neuroimaging. https://doi.org/10.1111/jon.13133

Vancouver

Tonroe T, McDermott H, Pearce P, Acevedo N, Thevathasan W, Xu SS, et al. Anatomical targeting for electrode localization in subthalamic nucleus deep brain stimulation: A comparative study. Journal of Neuroimaging. 2023. doi:10.1111/jon.13133

BibTeX
@article{Tonroe2023,
  author = {Tonroe, Thomas and McDermott, Hugh and Pearce, Patrick and Acevedo, Nicola and Thevathasan, Wesley and Xu, San San and Bulluss, Kristian and Perera, Thushara},
  title = {Anatomical targeting for electrode localization in subthalamic nucleus deep brain stimulation: A comparative study},
  journal = {Journal of Neuroimaging},
  year = {2023},
  doi = {10.1111/jon.13133}
}
Start for free →