EUVIMEDSkopri EUVIMED
Open access · CC BY-NC-ND 4.0

Transorbital sonography and MRI reliability to assess optic nerve sheath diameter in idiopathic intracranial hypertension

Sebastian Niclas Roemer iD, Erik Bernhard Friedrich, Michael Kettner iD, Martina Rauzi, Peter Schub, Johann Kulikovski, Daniel Janitschke iD, Jakob Stögbauer iD, Piergiorgio Lochner

Journal of Neuroimaging · 2023

DOI: 10.1111/jon.13092 ↗

At a glance

Journal article in Journal of Neuroimaging, 2023. Written by Sebastian Niclas Roemer and 8 co-authors. Institution: Department of Neurology, University Hospital, LMU Munich, Munich, Germany. Major MEDLINE topics: Pseudotumor Cerebri, Intracranial Hypertension. Cited 10 times so far (Crossref); 20 references. The full text is freely available (open access, CC BY-NC-ND 4.0).

AstrattSubjectsDettalji biblijografiċiCiteRelated studies

Abstract (original language)

Background and Purpose The purpose of this study was to evaluate the performance of magnetic resonance imaging (MRI) in measuring the optic nerve sheath diameter (ONSD) compared to the established method transorbital sonography (TOS) in patients with idiopathic intracranial hypertension (IIH).

Methods

Twenty‐three patients with IIH were prospectively included applying IIH diagnostic criteria. All patients received a lumbar puncture with assessment of the cerebrospinal fluid (CSF) opening pressure to assure the IIH diagnosis. Measurement of ONSD was performed 3 mm posterior to inner sclera surface in B‐TOS by an expert examiner, while three independent neuroradiologists took measurements in axial T‐weighted MRI examinations. The sella turcica with the pituitary gland (and potential presence of an empty sella) and the trigeminal cavity were also assessed on sagittal and transversal T1‐weighted MRI images by one independent neuroradiologist.

Results

The means of ONSD between ultrasound and MRI measurements were 6.3 mm (standard deviation [SD] = 0.6 mm) and 6.2 mm (SD = 0.8 mm). The interrater reliability between three neuroradiologists showed a high interclass correlation coefficient (ICC) (confidence interval: .573 < ICC < .8; p < .001). In patients with an empty sella, the ONSD evaluated by MRI was 6.6 mm, while measuring 6.1 mm in patients without empty sella. No correlation between CSF opening pressure and ONSD was found.

Conclusions

MRI can reliably measure ONSD and yields similar results compared to TOS in patients with IIH. Moreover, patients with empty sella showed significantly larger ONSD than patients without empty sella.

Subjects

MeSH terms (MEDLINE)

Pseudotumor CerebriIntracranial HypertensionHumansReproducibility of ResultsOptic NerveUltrasonographyIntracranial PressureMagnetic Resonance Imaging

Author keywords

MRIONSDidiopathic intracranial hypertensiontransorbital sonography

Authors and institutions

  • Department of Neurology, University Hospital, LMU Munich, Munich, Germany.
  • Institute for Stroke and Dementia Research (ISD), University Hospital, LMU Munich, Munich, Germany.
  • Department of Neurology, Saarland University Medical Center, Homburg, Germany.
  • Department of Neuroradiology, Saarland University Medical Center, Homburg, Germany.

ORCID profiles: Sebastian Niclas Roemer, Michael Kettner, Daniel Janitschke, Jakob Stögbauer

Cite

APA

Roemer, S. N., Friedrich, E. B., Kettner, M., Rauzi, M., Schub, P., Kulikovski, J., Janitschke, D., Stögbauer, J., & Lochner, P. (2023). Transorbital sonography and MRI reliability to assess optic nerve sheath diameter in idiopathic intracranial hypertension. Journal of Neuroimaging. https://doi.org/10.1111/jon.13092

Vancouver

Roemer SN, Friedrich EB, Kettner M, Rauzi M, Schub P, Kulikovski J, et al. Transorbital sonography and MRI reliability to assess optic nerve sheath diameter in idiopathic intracranial hypertension. Journal of Neuroimaging. 2023. doi:10.1111/jon.13092

BibTeX
@article{Roemer2023,
  author = {Roemer, Sebastian Niclas and Friedrich, Erik Bernhard and Kettner, Michael and Rauzi, Martina and Schub, Peter and Kulikovski, Johann and Janitschke, Daniel and Stögbauer, Jakob and Lochner, Piergiorgio},
  title = {Transorbital sonography and MRI reliability to assess optic nerve sheath diameter in idiopathic intracranial hypertension},
  journal = {Journal of Neuroimaging},
  year = {2023},
  doi = {10.1111/jon.13092}
}
Start for free →