EUVIMEDEUVIMED entdecken
Crossref

Diagnostic accuracy of a specialized pro forma in assessing morbidly adherent placenta in correlation to intra‐operative findings

Fatma F Ismail iD, Hassan M Gaafar, Moutaz M Elsherbini, Abdalla Mousa

Journal of Obstetrics and Gynaecology Research · 2025

DOI: 10.1111/jog.16314 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Obstetrics and Gynaecology Research, 2025. Verfasst von Fatma F Ismail und 3 weiteren Autor:innen. Beteiligte Einrichtung: Obstetrics and Gynecology Department, Students' Hospital, Cairo University, Giza, Egypt. Hauptthemen laut MEDLINE: Placenta Accreta, Ultrasonography, Prenatal, Ultrasonography, Doppler, Color. Die Arbeit nennt 20 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Objectives

To assess the clinical value of ultrasound criteria for the “Morbidly Adherent Placenta” (MAP) and the diagnostic accuracy of a customized “pro forma” in predicting MAP, its extent, and its relationship to intra‐operative results.

Methods

Twenty‐one pregnant women with a high possibility of placenta accreta were included in the study. Gray scale transabdominal and transvaginal ultrasound with color Doppler were done to confirm the MAP diagnosis and evaluate the signs of placental invasion. The ultrasound findings were compared with the operative details to predict placental invasion (focal or diffuse) and vascularity of the lower uterine segment to assess the clinical significance of the customized “pro forma.” Results There was a good accuracy of ultrasound signs to detect the vascularity of the lower uterine segment with a sensitivity of 94.12%, specificity of 25%, positive predictive value (PPV) of 84.21%, negative predictive value (NPV) of 50%, and accuracy of 80.95%; however, it was insignificant ( p = 0.352). Additionally, we found a good accuracy of ultrasound signs to detect the degree of placental invasion (focal or diffuse), with a sensitivity of 71.43%, specificity of 100%, PPV of 100%, NPV of 63.64%, and accuracy of 80.95%, which was significant ( p = 0.004).

Conclusion

This customized “pro forma” has satisfactory accuracy in predicting MAP cases with anterior placenta previa or anterior low‐lying placenta.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Placenta AccretaUltrasonography, PrenatalUltrasonography, Doppler, ColorHumansFemalePregnancyAdultSensitivity and SpecificityYoung AdultPlacenta

Stichwörter der Autor:innen

abnormal placentationmorbidly adherent placentaplacental mappingultrasound pro forma

Autor:innen und Institutionen

  • Obstetrics and Gynecology Department, Students' Hospital, Cairo University, Giza, Egypt.
  • Obstetrics and Gynecology Department, Faculty of Medicine, Cairo University, Giza, Egypt.

ORCID-Profile: Fatma F Ismail

Zitieren

APA

Ismail, F. F., Gaafar, H. M., Elsherbini, M. M., & Mousa, A. (2025). Diagnostic accuracy of a specialized pro forma in assessing morbidly adherent placenta in correlation to intra‐operative findings. Journal of Obstetrics and Gynaecology Research. https://doi.org/10.1111/jog.16314

Vancouver

Ismail FF, Gaafar HM, Elsherbini MM, Mousa A. Diagnostic accuracy of a specialized pro forma in assessing morbidly adherent placenta in correlation to intra‐operative findings. Journal of Obstetrics and Gynaecology Research. 2025. doi:10.1111/jog.16314

BibTeX
@article{Ismail2025,
  author = {Ismail, Fatma F and Gaafar, Hassan M and Elsherbini, Moutaz M and Mousa, Abdalla},
  title = {Diagnostic accuracy of a specialized pro forma in assessing morbidly adherent placenta in correlation to intra‐operative findings},
  journal = {Journal of Obstetrics and Gynaecology Research},
  year = {2025},
  doi = {10.1111/jog.16314}
}