EUVIMEDEUVIMED entdecken
Crossref

Telemedicine ultrasound assessment for placenta accreta spectrum: Utility and interobserver reliability of asynchronous remote imaging review

Albaro José Nieto-Calvache iD, Juan Pablo Benavides-Calvache iD, Rozi Aryananda iD, Jose M Palacios-Jaraquemada iD, Eric Jauniaux iD, Karin A Fox iD, Conrado Milani Coutinho iD, Theophilus Adu-Bredu iD, Jin-Chung Shih iD, Ahmed M Hussein iD, Ilan E Timor-Tritsch iD, Helena C Bartels iD und 8 weitere

International Journal of Gynecology & Obstetrics · 2025

DOI: 10.1002/ijgo.15991 ↗

Kurz gefasst

Fachartikel in der Zeitschrift International Journal of Gynecology & Obstetrics, 2025. Verfasst von Albaro José Nieto-Calvache und 19 weiteren Autor:innen. Beteiligte Einrichtung: Fundación Valle del Lili, Departamento de Ginecología y Obstetricia, Clínica de Espectro de Acretismo Placentario. Cra 98 No. 18-49, Cali, Colombia. Hauptthemen laut MEDLINE: Placenta Accreta, Ultrasonography, Prenatal, Remote Consultation. Die Arbeit wurde bisher 12-mal zitiert (Crossref) und nennt 23 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Objective

Management of patients with placenta accreta spectrum (PAS) by trained multidisciplinary teams is associated with improved outcomes. Ultrasound can predict intraoperative risks, but expert ultrasound imaging of PAS is often limited. Telemedicine is used increasingly in obstetrics, permitting expert consultation when essential resources are not available locally. Our objective was to evaluate the feasibility of teleconsultation using standardized ultrasound image acquisition and reporting, and to correlate prognosis with intraoperative findings in patients at risk for PAS.

Methods

A total of 12 PAS imaging experts (teleconsultants) were selected to asynchronously review deidentified standardized grayscale and color Doppler ultrasound images for five patients who had completed treatment for PAS, resulting in 60 individual teleconsultations. All patients were managed at a center using standardized imaging acquisition and intraoperative topographic classification to individualize surgical management. Teleconsultants reported the predicted topographic classification and recommended a surgical approach based on the topographic classification algorithm. Prognoses were compared with that reported by the local sonologist and with intraoperative findings.

Results

In all five patients, local sonologist prognosis and antenatal topographic classification was confirmed during surgery and the final surgical approach matched that which was recommended preoperatively. Teleconsultant antenatal evaluation and management plans matched those of the local team in 71.7% of the cases. When reports differed, PAS severity was overestimated in nine reviews (16.9%) and was underestimated in six reviews (11.3%).

Conclusion

Remote imaging teleconsultation provides accurate prenatal staging in most patients at risk for PAS. Teleconsultation is a feasible strategy to improve prenatal imaging, management planning, and guidance for local teams in settings with limited healthcare resources.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Placenta AccretaUltrasonography, PrenatalRemote ConsultationHumansFemalePregnancyAdultFeasibility StudiesReproducibility of ResultsObserver VariationPrognosisTelemedicineUltrasonography, Doppler, Color

Stichwörter der Autor:innen

placenta accreta spectrumsurgical planningtelehealthtelemedicinetele‐ultrasound

Autor:innen und Institutionen

  • Fundación Valle del Lili, Departamento de Ginecología y Obstetricia, Clínica de Espectro de Acretismo Placentario. Cra 98 No. 18-49, Cali, Colombia.
  • Doctoral School, Amsterdam University Medical Center, Amsterdam, The Netherlands.
  • Maternal-Fetal Medicine Division, Obstetrics & Gynecology Department, Dr. Soetomo Academic General Hospital, Universitas Airlangga, Surabaya, Indonesia.
  • Hospital Universitario CEMIC, Buenos Aires, Argentina.
  • EGA Institute for Women's Health, Faculty of Population Health Sciences, University College London (UCL), London, UK.
  • University of Texas Medical Branch at Galveston, Galveston, Texas, USA.

ORCID-Profile: Albaro José Nieto-Calvache, Juan Pablo Benavides-Calvache, Rozi Aryananda, Jose M Palacios-Jaraquemada, Eric Jauniaux, Karin A Fox, Conrado Milani Coutinho, Theophilus Adu-Bredu, Jin-Chung Shih, Ahmed M Hussein, Ilan E Timor-Tritsch, Helena C Bartels, Jorge Hamer, Francesco D'Antonio, Alejandro Solo Nieto-Calvache, Jaime Octavio López, Luisa Fernanda Rivera-Torres, Marcus J Rijken

Zitieren

APA

Nieto-Calvache, A. J., Benavides-Calvache, J. P., Aryananda, R., Palacios-Jaraquemada, J. M., Jauniaux, E., Fox, K. A., Coutinho, C. M., Adu-Bredu, T., Shih, J. C., Hussein, A. M., Timor-Tritsch, I. E., Bartels, H. C., Hamer, J., Cali, G., D'Antonio, F., Nieto-Calvache, A. S., López, J. O., Rivera-Torres, L. F., Pajkrt, E., & Rijken, M. J. (2025). Telemedicine ultrasound assessment for placenta accreta spectrum: Utility and interobserver reliability of asynchronous remote imaging review. International Journal of Gynecology & Obstetrics. https://doi.org/10.1002/ijgo.15991

Vancouver

Nieto-Calvache AJ, Benavides-Calvache JP, Aryananda R, Palacios-Jaraquemada JM, Jauniaux E, Fox KA, et al. Telemedicine ultrasound assessment for placenta accreta spectrum: Utility and interobserver reliability of asynchronous remote imaging review. International Journal of Gynecology & Obstetrics. 2025. doi:10.1002/ijgo.15991

BibTeX
@article{NietoCalvache2025,
  author = {Nieto-Calvache, Albaro José and Benavides-Calvache, Juan Pablo and Aryananda, Rozi and Palacios-Jaraquemada, Jose M and Jauniaux, Eric and Fox, Karin A and Coutinho, Conrado Milani and Adu-Bredu, Theophilus and Shih, Jin-Chung and Hussein, Ahmed M and Timor-Tritsch, Ilan E and Bartels, Helena C and Hamer, Jorge and Cali, Giuseppe and D'Antonio, Francesco and Nieto-Calvache, Alejandro Solo and López, Jaime Octavio and Rivera-Torres, Luisa Fernanda and Pajkrt, Eva and Rijken, Marcus J},
  title = {Telemedicine ultrasound assessment for placenta accreta spectrum: Utility and interobserver reliability of asynchronous remote imaging review},
  journal = {International Journal of Gynecology & Obstetrics},
  year = {2025},
  doi = {10.1002/ijgo.15991}
}
Kostenlos starten →