Nonsurgical Facial Contouring With a Novel Radiofrequency and Vacuum Device: A Multicenter Retrospective Study With 33 Patients
Journal of Cosmetic Dermatology · 2025
DOI: 10.1111/jocd.70127 ↗Kurz gefasst
Multizentrische Studie in der Zeitschrift Journal of Cosmetic Dermatology, 2025. Verfasst von Mimi Ehrenraich und 5 weiteren Autor:innen. Beteiligte Einrichtung: Mimi Ehrenraich Aesthetic Clinics, Haifa, Israel. Hauptthemen laut MEDLINE: Skin Aging, Cosmetic Techniques, Radiofrequency Therapy. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 19 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Background
The aging process reflects decreased tissue elasticity and a rearrangement of subcutaneous volume, resulting in superficial wrinkles and three‐dimensional changes in skin topography. Radiofrequency (RF)‐based approaches have become increasingly adopted in recent decades due to their relatively short downtime and significantly reduced risk of adverse effects.
Aims
The aim of this study was to evaluate the safety and efficacy of the V‐FC handpiece through a multicenter retrospective study as well as ex vivo and in vivo analyses.
Methods
The V‐FC handpiece was used once a week for a treatment course of 3–6 sessions. The clinical evaluation of 33 patients included demographics, BMI, assessment of skin laxity, and rate of improvement. An ex vivo study with porcine tissue assessed the penetration depth of RF, while device performance was evaluated in an in vivo animal histological analysis.
Results
No significant adverse effects were recorded during the treatment course or at short‐ and long‐term follow‐ups (1, 3, and 52 months). The average skin laxity grade baseline was 34% lower at the end of the treatment course, with the average rate of improvement assessed as moderate. The ex vivo minimal and maximal penetration depths were 3.2–11.3 mm (±10%). The in vivo histopathological analysis showed no signs of acute heat injury at any treatment setting, including the maximum RF power. Additionally, staining showed a power‐related progressive proliferation of fibroblasts, elastin fibers, and neocollagenesis, which was significantly higher 4 weeks after treatment.
Conclusions
The new RF device demonstrates an effective treatment for facial contouring with a proven short‐ and long‐term high safety profile.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Mimi Ehrenraich Aesthetic Clinics, Haifa, Israel.
- Wolff Aesthetics Center, Herzliya, Israel.
- Arival Ltd., Tel-Aviv, Israel.
- Sinclair, London, UK.
Zitieren
APA
Ehrenraich, M., Wolff, E., Grumer, S. R., Lozano, O. C., Vargas, R., & Belenky, I. (2025). Nonsurgical Facial Contouring With a Novel Radiofrequency and Vacuum Device: A Multicenter Retrospective Study With 33 Patients. Journal of Cosmetic Dermatology. https://doi.org/10.1111/jocd.70127
Vancouver
Ehrenraich M, Wolff E, Grumer SR, Lozano OC, Vargas R, Belenky I. Nonsurgical Facial Contouring With a Novel Radiofrequency and Vacuum Device: A Multicenter Retrospective Study With 33 Patients. Journal of Cosmetic Dermatology. 2025. doi:10.1111/jocd.70127
BibTeX
@article{Ehrenraich2025,
author = {Ehrenraich, Mimi and Wolff, Ety and Grumer, Suzy Roffe and Lozano, Olalla Calvo and Vargas, Reyna and Belenky, Inna},
title = {Nonsurgical Facial Contouring With a Novel Radiofrequency and Vacuum Device: A Multicenter Retrospective Study With 33 Patients},
journal = {Journal of Cosmetic Dermatology},
year = {2025},
doi = {10.1111/jocd.70127}
}
EUVIMED