Thermal Accumulation and Collagen Remodeling in Porcine Models: Parameter‐Dependent Efficacy of Micro‐Focused Ultrasound for Human Facial Skin Tightening
Journal of Cosmetic Dermatology · 2026
DOI: 10.1111/jocd.70719 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Cosmetic Dermatology, 2026. Verfasst von Jing Qi und 3 weiteren Autor:innen. Beteiligte Einrichtung: Department of Dermatology, Xuan Wu Hospital, Capital Medical University, Beijing, China. Hauptthemen laut MEDLINE: Skin Aging, Collagen, Ultrasonic Therapy, Cosmetic Techniques. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 21 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Background
Skin laxity, driven by collagen/elastin degradation and aging, is targeted by micro‐focused ultrasound (MFU) through depth‐specific thermal coagulation to induce collagen remodeling, yet parameter‐dependent thermal kinetics and safety thresholds remain underexplored, limiting protocol optimization.
Aims
To validate the dose‐effect relationship of MFU using in vitro porcine skin tissues and evaluate its safety and efficacy for human facial skin tightening.
Methods
Porcine skin tissues containing intact skin, fat, and muscle layers were treated with 8D‐DL 3.0, 8D‐DL 4.5, Vmax‐DL 3.0, and Vmax‐DL 4.5 handpieces. Subcutaneous temperatures at depths of 2.0 mm, 3.0 mm, 4.5 mm, and 6.0 mm were recorded under varying parameters (energy levels and exposure durations). Twenty patients undergoing single‐session MFU facial treatment between June and August 2024 were enrolled. Skin tightening outcomes were assessed at 30‐ and 90‐days post‐treatment.
Results
For 8D‐DL 3.0 and Vmax‐DL 3.0 handpieces, peak temperatures occurred at 3.0 mm depth across all energy levels and exposure durations. For 8D‐DL 4.5 and Vmax‐DL 4.5 handpieces, peak temperatures localized at 4.5 mm. Focal depth temperatures increased significantly with higher energy levels and prolonged exposure. At 30‐ and 90‐days post‐treatment, upward displacement and volume reduction in bilateral cheek and jawline regions were observed. Mild procedural pain was reported, with no adverse events.
Conclusion
MFU‐induced thermal peaks align with preset focal depths, demonstrating parameter‐dependent thermal accumulation. The procedure safely achieves clinically significant facial skin tightening.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Dermatology, Xuan Wu Hospital, Capital Medical University, Beijing, China.
- Hunan JIANFLASER Laser Medical Technology Co., Ltd., Changsha, Hunan Province, China.
- Hunan Provincial Drug Evaluation and Adverse Reaction Monitoring Center, Changsha, Hunan Province, China.
ORCID-Profile: Jing Qi, Haiping Zhang
Zitieren
APA
Qi, J., Wei, B., Pan, J., & Zhang, H. (2026). Thermal Accumulation and Collagen Remodeling in Porcine Models: Parameter‐Dependent Efficacy of Micro‐Focused Ultrasound for Human Facial Skin Tightening. Journal of Cosmetic Dermatology. https://doi.org/10.1111/jocd.70719
Vancouver
Qi J, Wei B, Pan J, Zhang H. Thermal Accumulation and Collagen Remodeling in Porcine Models: Parameter‐Dependent Efficacy of Micro‐Focused Ultrasound for Human Facial Skin Tightening. Journal of Cosmetic Dermatology. 2026. doi:10.1111/jocd.70719