EUVIMEDScopri EUVIMED
Open access · CC BY 4.0

Artificial Intelligence‐Driven Automated Design of Anterior and Posterior Crowns Under Diverse Occlusal Scenarios

Nan Hsu Myat Mon Hlaing iD, Gülce Çakmak iD, Duygu Karasan iD, Sung-Jin Kim iD, Irena Sailer iD, Jae-Hyun Lee iD

Journal of Esthetic and Restorative Dentistry · 2026

DOI: 10.1111/jerd.70029 ↗

At a glance

Journal article in Journal of Esthetic and Restorative Dentistry, 2026. Written by Nan Hsu Myat Mon Hlaing and 5 co-authors. Institution: Department of Prosthodontics, Seoul National University School of Dentistry, Seoul, Republic of Korea. Major MEDLINE topics: Crowns, Artificial Intelligence, Computer-Aided Design, Dental Occlusion. Cited 10 times so far (Crossref); 37 references. The full text is freely available (open access, CC BY 4.0). Funded by: National Research Foundation of Korea, Korea Medical Device Development Fund, Chung Mong-Koo Foundation.

AbstractSubjectsDati bibliograficiCiteRelated studies

Abstract (original language)

Objective

To evaluate the impact of occlusion type and artificial intelligence‐based computer‐aided design (CAD) software on the geometric accuracy and clinical quality of auto‐generated anterior and posterior crown designs.

Methods

Five typodont models representing various occlusion types (normal, Class I anterior diastema, Class II division 1, Class II division 2, and Class III anterior crossbite occlusion) underwent crown preparation for the maxillary right central incisor and first molar. Ten sets of intraoral scans were obtained from each prepared model, and crown designs were automatically generated using two software programs: deep learning‐based (DL; Dentbird) and conventional automated (CA; Auto Workflow, 3Shape) ( n = 10). Surface deviations between the crown designs and preoperative tooth morphology were quantified using root mean square (RMS) values. Clinical crown quality was assessed using World Dental Federation (FDI) criteria. Scheirer–Ray–Hare and Fisher's exact tests were conducted ( α = 0.05).

Results

Significant differences in surface deviation and clinical quality were observed between the various occlusion and software types. The DL group demonstrated higher RMS values than the CA group ( p < 0.001). However, DL‐generated crowns were of significantly better clinical quality (FDI scores) than CA‐generated crowns, particularly for posterior teeth, in terms of marginal adaptation, proximal contacts, and anatomical form and contour ( p < 0.05). The DL group demonstrated generally favorable outcomes when designing crowns for normal occlusion, but outcomes were less satisfactory when designing anterior crowns with diastemas.

Conclusions

Occlusal scenarios influenced the surface deviation and quality of auto‐generated anterior and posterior crown designs. DL software produced higher‐quality molar designs than CA software. Clinical Significance Automated crown design outcomes depend on occlusal scenarios and CAD software selection. DL‐based CAD software demonstrated superior clinical quality, particularly for posterior crowns, indicating higher clinical suitability. However, further software refinement is needed to consistently produce clinically acceptable crowns under diverse occlusal conditions, such as anterior diastemas.

Subjects

MeSH terms (MEDLINE)

CrownsArtificial IntelligenceComputer-Aided DesignDental OcclusionDental Prosthesis DesignHumansMolarSoftwareModels, Dental

Author keywords

artificial intelligencecomputer‐aided designdental occlusiondental prosthesis designdental restoration

Authors and institutions

  • Department of Prosthodontics, Seoul National University School of Dentistry, Seoul, Republic of Korea.
  • Department of Reconstructive Dentistry and Gerodontology, School of Dental Medicine, University of Bern, Bern, Switzerland.
  • Department of Prosthodontics, Geriatric Dentistry and Craniomandibular Disorders, Charité-Universitätsmedizin Berlin, Corporate Member of Freie Universität Berlin and Humboldt-Universität Zu Berlin, Berlin, Germany.
  • Division of Fixed Prosthodontics and Biomaterials, Clinique Universitaire de Médecine Dentaire (CUMD), University of Geneva, Geneva, Switzerland.
  • Dental Research Institute, Seoul National University School of Dentistry, Seoul, Republic of Korea.

ORCID profiles: Nan Hsu Myat Mon Hlaing, Gülce Çakmak, Duygu Karasan, Sung-Jin Kim, Irena Sailer, Jae-Hyun Lee

Funding

  • National Research Foundation of Korea
  • Korea Medical Device Development Fund
  • Chung Mong-Koo Foundation

Cite

APA

Hlaing, N. H. M. M., Çakmak, G., Karasan, D., Kim, S. J., Sailer, I., & Lee, J. H. (2026). Artificial Intelligence‐Driven Automated Design of Anterior and Posterior Crowns Under Diverse Occlusal Scenarios. Journal of Esthetic and Restorative Dentistry. https://doi.org/10.1111/jerd.70029

Vancouver

Hlaing NHMM, Çakmak G, Karasan D, Kim SJ, Sailer I, Lee JH. Artificial Intelligence‐Driven Automated Design of Anterior and Posterior Crowns Under Diverse Occlusal Scenarios. Journal of Esthetic and Restorative Dentistry. 2026. doi:10.1111/jerd.70029

BibTeX
@article{Hlaing2026,
  author = {Hlaing, Nan Hsu Myat Mon and Çakmak, Gülce and Karasan, Duygu and Kim, Sung-Jin and Sailer, Irena and Lee, Jae-Hyun},
  title = {Artificial Intelligence‐Driven Automated Design of Anterior and Posterior Crowns Under Diverse Occlusal Scenarios},
  journal = {Journal of Esthetic and Restorative Dentistry},
  year = {2026},
  doi = {10.1111/jerd.70029}
}
Start for free →