EUVIMEDOpdag EUVIMED
Crossref

Cephalometric analysis performance discrepancy between orthodontists and an artificial intelligence model using lateral cephalometric radiographs

Clara Guinot-Barona, Jorge Alonso Pérez-Barquero, Lidia Galán López, Abdul B Barmak, Wael Att, John C Kois, Marta Revilla-León iD

Journal of Esthetic and Restorative Dentistry · 2024-04 · 36 (4) · 555-565

DOI: 10.1111/jerd.13156 ↗

At a glance

Journal article in Journal of Esthetic and Restorative Dentistry, published online on 2023-10-26. Written by Clara Guinot-Barona and 6 co-authors. Institution: Department of Dental Orthodontics, Faculty of Medicine and Health Sciences, Catholic University of Valencia, Valencia, Spain. Major MEDLINE topics: Artificial Intelligence, Orthodontists. Cited 25 times so far (Crossref); 42 references.

AbstractSubjectsBibliografiske oplysningerCiteRelated studies

Abstract (original language)

Purpose

The purpose of the present clinical study was to compare the Ricketts and Steiner cephalometric analysis obtained by two experienced orthodontists and artificial intelligence (AI)‐based software program and measure the orthodontist variability. Materials and Methods A total of 50 lateral cephalometric radiographs from 50 patients were obtained. Two groups were created depending on the operator performing the cephalometric analysis: orthodontists (Orthod group) and an AI software program (AI group). In the Orthod group, two independent experienced orthodontists performed the measurements by performing a manual identification of the cephalometric landmarks and a software program (NemoCeph; Nemotec) to calculate the measurements. In the AI group, an AI software program (CephX; ORCA Dental AI) was selected for both the automatic landmark identification and cephalometric measurements. The Ricketts and Steiner cephalometric analyses were assessed in both groups including a total of 24 measurements. The Shapiro–Wilk test showed that the data was normally distributed. The t‐test was used to analyze the data ( α = 0.05).

Results

The t‐test analysis showed significant measurement discrepancies between the Orthod and AI group in seven of the 24 cephalometric parameters tested, namely the corpus length ( p = 0.003), mandibular arc ( p < 0.001), lower face height ( p = 0.005), overjet ( p = 0.019), and overbite ( p = 0.022) in the Ricketts cephalometric analysis and occlusal to SN ( p = 0.002) and GoGn‐SN ( p < 0.001) in the Steiner cephalometric analysis. The intraclass correlation coefficient (ICC) between both orthodontists of the Orthod group for each cephalometric measurement was calculated.

Conclusions

Significant discrepancies were found in seven of the 24 cephalometric measurements tested between the orthodontists and the AI‐based program assessed. The intra‐operator reliability analysis showed reproducible measurements between both orthodontists, except for the corpus length measurement. Clinical Significance The artificial intelligence software program tested has the potential to automatically obtain cephalometric analysis using lateral cephalometric radiographs; however, additional studies are needed to further evaluate the accuracy of this AI‐based system.

Subjects

MeSH terms (MEDLINE)

Artificial IntelligenceOrthodontistsHumansReproducibility of ResultsCephalometry

Author keywords

artificial intelligencecephalometric analysismachine learningorthodontics

Authors and institutions

  • Department of Dental Orthodontics, Faculty of Medicine and Health Sciences, Catholic University of Valencia, Valencia, Spain.
  • Department of Dental Medicine, Faculty of Medicine and Dentistry, University of Valencia, Valencia, Spain.
  • Clinical Research and Biostatistics, Eastman Institute of Oral Health, University of Rochester Medical Center, Rochester, New York, USA.
  • Department of Prosthodontics, University Hospital of Freiburg, Freiburg, Germany, USA.
  • Kois Center, Seattle, Washington, USA.
  • Department of Restorative Dentistry, School of Dentistry, University of Washington, Seattle, Washington, USA.

ORCID profiles: Marta Revilla-León

Cite

APA

Guinot-Barona, C., Alonso Pérez-Barquero, J., Galán López, L., Barmak, A. B., Att, W., Kois, J. C., & Revilla-León, M. (2024). Cephalometric analysis performance discrepancy between orthodontists and an artificial intelligence model using lateral cephalometric radiographs. Journal of Esthetic and Restorative Dentistry, 36(4), 555-565. https://doi.org/10.1111/jerd.13156

Vancouver

Guinot-Barona C, Alonso Pérez-Barquero J, Galán López L, Barmak AB, Att W, Kois JC, et al. Cephalometric analysis performance discrepancy between orthodontists and an artificial intelligence model using lateral cephalometric radiographs. Journal of Esthetic and Restorative Dentistry. 2024;36(4):555-565. doi:10.1111/jerd.13156

BibTeX
@article{GuinotBarona2024,
  author = {Guinot-Barona, Clara and Alonso Pérez-Barquero, Jorge and Galán López, Lidia and Barmak, Abdul B and Att, Wael and Kois, John C and Revilla-León, Marta},
  title = {Cephalometric analysis performance discrepancy between orthodontists and an artificial intelligence model using lateral cephalometric radiographs},
  journal = {Journal of Esthetic and Restorative Dentistry},
  year = {2024},
  volume = {36},
  number = {4},
  pages = {555--565},
  doi = {10.1111/jerd.13156}
}
Start for free →