EUVIMEDEUVIMED entdecken
Systematische Übersicht

Effect of contamination and decontamination methods on the bond strength of adhesive systems to dentin: A systematic review

Rim Bourgi iD, Carlos Enrique Cuevas-Suarez iD, Walter Devoto, Ana Josefina Monjarás-Ávila iD, Paulo Monteiro, Khalil Kharma iD, Monika Lukomska-Szymanska iD, Louis Hardan iD

Journal of Esthetic and Restorative Dentistry · 2023-12 · 35 (8) · 1218-1238

DOI: 10.1111/jerd.13078 ↗

Kurz gefasst

Systematische Übersicht in der Zeitschrift Journal of Esthetic and Restorative Dentistry, online erschienen am 03.07.2023. Verfasst von Rim Bourgi und 7 weiteren Autor:innen. Beteiligte Einrichtung: Department of Restorative Dentistry, School of Dentistry, Saint-Joseph University, Beirut, Lebanon. Hauptthemen laut MEDLINE: Decontamination, Dentin, Dental Bonding. Die Arbeit wurde bisher 17-mal zitiert (Crossref) und nennt 98 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Introduction

In a suitable condition, it is important to perform any dental restorative procedure using an operatory field isolated. Then, the aim of this study was to compare the bond strength of composite restorations to dentin affected by any contamination agent through a systematic review.

Methods

This systematic review was performed following the PRISMA 2020 guidelines. The literature search was conducted until September 2022 by scanning the following databases: Embase, PubMed, Scielo, Scopus, and Web of Science. Manuscripts evaluated the bond strength of resin‐based materials to permanent human dentin contaminated with blood or saliva were selected for full‐text review. The risk of bias was assessed by the RoBDEMAT tool.

Results

A total of 3750 papers resulted from the search from all databases. After the full‐text reading, a total of 62 articles remained for the qualitative analysis. The contamination agents used were blood, saliva, and hemostatic agents. A great variety of protocols were used to contaminate the dentin surface, and the contamination process occurred in several steps of the bonding process, including before and after the etching process, after the primer application and after the adhesive application. Also, several decontamination procedures were tested, including reapplication of the etching material, rinsing with water, chlorhexidine or sodium hypochlorite and reapplication of the adhesive system.

Conclusion

Any contamination with blood or saliva impaired the bond strength of resin‐based materials to dentin. Decontamination procedures including water‐spray and reapplication of the bonding system could revert the impairment produced by the saliva or blood contamination. The use of hemostatic agents as a method of blood decontamination is not recommended. Clinical Significance Clinicians should avoid contamination during a bonding procedure, otherwise, a reduction in the bond quality is expected.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

DecontaminationDentinDental BondingHumansComposite ResinsDentin-Bonding AgentsSalivaBlood

Stichwörter der Autor:innen

blooddentinhemostatic agentsaliva

Substanzen

Composite ResinsDentin-Bonding Agents

Autor:innen und Institutionen

  • Department of Restorative Dentistry, School of Dentistry, Saint-Joseph University, Beirut, Lebanon.
  • Department of Biomaterials and Bioengineering, INSERM UMR_S 1121, Biomaterials and Bioengineering, Strasbourg, France.
  • Dental Materials Laboratory, Academic Area of Dentistry, Autonomous University of Hidalgo State, Pachuca, Mexico.
  • Independent Researcher, Sestri Levante, Italy.
  • Clinical Research Unit (CRU), Centro de Investigação Interdisciplinar Egas Moniz (CiiEM), Egas Moniz, CRL, Caparica, Portugal.
  • Department of General Dentistry, Medical University of Lodz, Lodz, Poland.

ORCID-Profile: Rim Bourgi, Carlos Enrique Cuevas-Suarez, Ana Josefina Monjarás-Ávila, Khalil Kharma, Monika Lukomska-Szymanska, Louis Hardan

Zitieren

APA

Bourgi, R., Cuevas-Suarez, C. E., Devoto, W., Monjarás-Ávila, A. J., Monteiro, P., Kharma, K., Lukomska-Szymanska, M., & Hardan, L. (2023). Effect of contamination and decontamination methods on the bond strength of adhesive systems to dentin: A systematic review. Journal of Esthetic and Restorative Dentistry, 35(8), 1218-1238. https://doi.org/10.1111/jerd.13078

Vancouver

Bourgi R, Cuevas-Suarez CE, Devoto W, Monjarás-Ávila AJ, Monteiro P, Kharma K, et al. Effect of contamination and decontamination methods on the bond strength of adhesive systems to dentin: A systematic review. Journal of Esthetic and Restorative Dentistry. 2023;35(8):1218-1238. doi:10.1111/jerd.13078

BibTeX
@article{Bourgi2023,
  author = {Bourgi, Rim and Cuevas-Suarez, Carlos Enrique and Devoto, Walter and Monjarás-Ávila, Ana Josefina and Monteiro, Paulo and Kharma, Khalil and Lukomska-Szymanska, Monika and Hardan, Louis},
  title = {Effect of contamination and decontamination methods on the bond strength of adhesive systems to dentin: A systematic review},
  journal = {Journal of Esthetic and Restorative Dentistry},
  year = {2023},
  volume = {35},
  number = {8},
  pages = {1218--1238},
  doi = {10.1111/jerd.13078}
}
Kostenlos starten →