EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Effect of magnetic MMP removal on long‐term dentin collagen stability

Walter Zenobi iD, Salvatore Sauro iD, Davino Machado Andrade Neto iD, Karen Evellin Moura Cordeiro iD, Francisco Avelino iD, Diego Lomonaco iD, Pierre Basilio Almeida Fechine iD, Yu Fu Chou iD, Garrit Koller iD, Thiago Soares Porto iD, Victor Pinheiro Feitosa

European Journal of Oral Sciences · 2026

DOI: 10.1111/eos.70053 ↗

Kurz gefasst

Fachartikel in der Zeitschrift European Journal of Oral Sciences, 2026. Verfasst von Walter Zenobi und 10 weiteren Autor:innen. Beteiligte Einrichtung: Postgraduate Program of Dentistry, Federal University of Ceara, Fortaleza, Brazil. Hauptthemen laut MEDLINE: Dentin, Collagen, Matrix Metalloproteinases, Dental Bonding. Die Arbeit nennt 36 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Ministerio de Ciencia, Innovación y Universidades: AEI/10.13039/501100011033, Brazilian Ministry of Education CAPES, by Fundação Cearense de Apoio ao Desenvolvimento Científico e Tecnológico.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Several matrix metalloproteinase (MMP) inhibitors have been investigated for their ability to improve dentin‐bond longevity. However, MMPs tend to reactivate over time, especially using simplified etch‐and‐rinse adhesives. This study investigated a novel magnetic removal of dentinal MMPs on bonding durability, MMP inhibition and collagen degradation. Magnetic nanoparticles (Fe 3 O 4 ) were synthesized, characterized, and incorporated in water‐based gels at 2 wt% (MAG‐2) or 20 wt% (MAG‐20). A placebo and 2 wt% chlorhexidine (CHX) digluconate gel were employed as control treatments. Human teeth were acid‐etched, pretreated with gels (external magnetic motion was created in the MAG groups), and bonded to composite using a simplified adhesive. Specimens were subjected to microtensile bond strength test after 24 h or 1 year of water storage. Interface release of hydroxyproline was assessed. Presence of MMPs was analyzed by confocal microscopy in situ zymography. Data were statistically analyzed using two‐way ANOVA and Tukey's test. MAG‐2 was the only treatment providing stable bond strength, revealing lower MMP activity than CHX. MAG‐2 produced an evident removal of MMPs compared to CHX, MAG‐20, and placebo. The innovative magnetic treatment of dentin was able to effectively remove MMPs when used at a 2 wt% concentration, arresting dentin collagen degradation at the dentin‐bonded and achieving stable bonding over time.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

DentinCollagenMatrix MetalloproteinasesDental BondingMatrix Metalloproteinase InhibitorsMagnetite NanoparticlesHumansTensile StrengthDentin-Bonding AgentsChlorhexidineMaterials TestingAcid Etching, DentalHydroxyprolineComposite ResinsMicroscopy, ConfocalPlacebos

Stichwörter der Autor:innen

Fe3O4 nanoparticlesadhesiondentindurabilitymetalloproteinase

Substanzen

CollagenMatrix MetalloproteinasesDentin-Bonding AgentsMatrix Metalloproteinase InhibitorsChlorhexidineHydroxyprolineMagnetite NanoparticlesComposite ResinsPlacebos

Autor:innen und Institutionen

  • Postgraduate Program of Dentistry, Federal University of Ceara, Fortaleza, Brazil.
  • Dental Biomaterials & Minimally Invasive Dentistry, Department of Dentistry, University CEU Cardenal Herrera, Valencia, Spain.
  • Department of Materials and Metallurgic Engineering, Federal University of Ceara, Fortaleza, Brazil.
  • Department of Organic and Inorganic Chemistry, Federal University of Ceara, Fortaleza, Brazil.
  • Department of Analytic and Physics-Chemistry, Federal University of Ceara, Fortaleza, Brazil.
  • King's College London Dental Institute, London, UK.

ORCID-Profile: Walter Zenobi, Salvatore Sauro, Davino Machado Andrade Neto, Karen Evellin Moura Cordeiro, Francisco Avelino, Diego Lomonaco, Pierre Basilio Almeida Fechine, Yu Fu Chou, Garrit Koller, Thiago Soares Porto

Förderung

  • Ministerio de Ciencia, Innovación y Universidades: AEI/10.13039/501100011033
  • Brazilian Ministry of Education CAPES
  • by Fundação Cearense de Apoio ao Desenvolvimento Científico e Tecnológico

Zitieren

APA

Zenobi, W., Sauro, S., Andrade Neto, D. M., Cordeiro, K. E. M., Avelino, F., Lomonaco, D., Fechine, P. B. A., Chou, Y. F., Koller, G., Porto, T. S., & Feitosa, V. P. (2026). Effect of magnetic MMP removal on long‐term dentin collagen stability. European Journal of Oral Sciences. https://doi.org/10.1111/eos.70053

Vancouver

Zenobi W, Sauro S, Andrade Neto DM, Cordeiro KEM, Avelino F, Lomonaco D, et al. Effect of magnetic MMP removal on long‐term dentin collagen stability. European Journal of Oral Sciences. 2026. doi:10.1111/eos.70053

BibTeX
@article{Zenobi2026,
  author = {Zenobi, Walter and Sauro, Salvatore and Andrade Neto, Davino Machado and Cordeiro, Karen Evellin Moura and Avelino, Francisco and Lomonaco, Diego and Fechine, Pierre Basilio Almeida and Chou, Yu Fu and Koller, Garrit and Porto, Thiago Soares and Feitosa, Victor Pinheiro},
  title = {Effect of magnetic MMP removal on long‐term dentin collagen stability},
  journal = {European Journal of Oral Sciences},
  year = {2026},
  doi = {10.1111/eos.70053}
}
Kostenlos starten →