EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC 4.0

Effect of switching from intermittently scanned continuous glucose monitoring to FreeStyle Libre 2 with real‐time continuous glucose monitoring and alert functionality

Keiji Sugai iD, Junko Sasaki, Gakuyuki Tomizawa, Ryo Suzuki iD

Journal of Diabetes Investigation · 2026

DOI: 10.1111/jdi.70233 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Diabetes Investigation, 2026. Verfasst von Keiji Sugai und 3 weiteren Autor:innen. Beteiligte Einrichtung: Department of Diabetes, Metabolism and Endocrinology, Tokyo Medical University, Tokyo, Japan. Hauptthemen laut MEDLINE: Continuous Glucose Monitoring, Diabetes Mellitus, Type 1, Blood Glucose, Diabetes Mellitus, Type 2. Die Arbeit nennt 25 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Aims/Introduction This study aimed to assess the impact of switching from FreeStyle Libre (FSL) to FreeStyle Libre 2 (FSL2) with real‐time continuous glucose monitoring (rtCGM) functionality. Materials and Methods We retrospectively assessed 58 patients who transitioned from FSL to FSL2 with rtCGM functionality.

Results

Switching from FSL to FSL2 significantly increased the valid data acquisition rate (76.8% ± 21.6% vs 90.4% ± 18.0%, P < 0.001). Time in range (TIR) improved from 57.7% ± 18.1% to 61.7% ± 17.1% ( P = 0.023); time in tight range improved from 33.3% ± 15.4% to 38.6% ± 16.9% ( P = 0.006), and glycated hemoglobin decreased from 7.6% ± 1.1% to 7.4% ± 1.0% ( P = 0.009). TIR improvement was immediate in Type 1 diabetes but gradual after an initial decline in Type 2 diabetes. Logistic regression identified younger age as a predictor of TIR improvement (odds ratio: 0.95, 95% confidence interval: 0.90–0.99, P = 0.034).

Conclusions

Transitioning from FSL to FSL2 with rtCGM functionality improved valid data acquisition rate and glycemic control, particularly in patients with Type 1 diabetes. The duration required for improvement in continuous glucose monitoring‐related parameters varied by diabetes type, with early improvements observed in Type 1 diabetes and gradual improvements in Type 2 diabetes.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Continuous Glucose MonitoringDiabetes Mellitus, Type 1Blood GlucoseDiabetes Mellitus, Type 2Blood Glucose Self-MonitoringHumansRetrospective StudiesFemaleMaleMiddle AgedGlycated HemoglobinAdult

Stichwörter der Autor:innen

Continuous glucose monitoringDiabetes mellitusTime in tight range

Substanzen

Blood GlucoseGlycated Hemoglobin

Autor:innen und Institutionen

  • Department of Diabetes, Metabolism and Endocrinology, Tokyo Medical University, Tokyo, Japan.

ORCID-Profile: Keiji Sugai, Ryo Suzuki

Zitieren

APA

Sugai, K., Sasaki, J., Tomizawa, G., & Suzuki, R. (2026). Effect of switching from intermittently scanned continuous glucose monitoring to FreeStyle Libre 2 with real‐time continuous glucose monitoring and alert functionality. Journal of Diabetes Investigation. https://doi.org/10.1111/jdi.70233

Vancouver

Sugai K, Sasaki J, Tomizawa G, Suzuki R. Effect of switching from intermittently scanned continuous glucose monitoring to FreeStyle Libre 2 with real‐time continuous glucose monitoring and alert functionality. Journal of Diabetes Investigation. 2026. doi:10.1111/jdi.70233

BibTeX
@article{Sugai2026,
  author = {Sugai, Keiji and Sasaki, Junko and Tomizawa, Gakuyuki and Suzuki, Ryo},
  title = {Effect of switching from intermittently scanned continuous glucose monitoring to FreeStyle Libre 2 with real‐time continuous glucose monitoring and alert functionality},
  journal = {Journal of Diabetes Investigation},
  year = {2026},
  doi = {10.1111/jdi.70233}
}
Kostenlos starten →