EUVIMEDOpdag EUVIMED
Open access · CC BY-NC 4.0

First‐in‐Man Study of a Novel Peripheral Plaque Atherectomy Device

Hui Wang, Dikang Pan, Shijun Cui, Zhu Tong, Xixiang Gao, Yongquan Gu iD, Jianming Guo iD, Lianrui Guo

The Journal of Clinical Hypertension · 2025

DOI: 10.1111/jch.14967 ↗

At a glance

Journal article in The Journal of Clinical Hypertension, 2025. Written by Hui Wang and 7 co-authors. Institution: Department of Vascular Surgery, Xuanwu Hospital, Capital Medical University, Beijing, China. Major MEDLINE topics: Atherectomy, Peripheral Arterial Disease, Plaque, Atherosclerotic. 28 references. The full text is freely available (open access, CC BY-NC 4.0). Funded by: Beijing Municipal Science & Technology Commission.

AbstractSubjectsBibliografiske oplysningerCiteRelated studies

Abstract (original language)

This first‐in‐man (FIM) study evaluated the feasibility and safety of a new peripheral plaque atherectomy system in patients with symptomatic lower extremity artery disease (LEAD). Ten patients with symptomatic LEAD (Rutherford class 2–5) were enrolled in a prospective, single‐center study from March to April 2024. Patients aged 18–85 years with target lesions showing ≥70% stenosis and reference vessel diameters ≥1.8 mm underwent treatment using a novel atherectomy device with a “shaving” mechanism to excise calcified plaques. Outcomes included post‐procedural stenosis improvement, 6‐month primary patency rate, and safety endpoints such as thrombosis, vasospasm, acute occlusion, and distal embolization. Statistical analysis used SPSS 23.0. Ten male patients (mean age: 61.4 ± 9.2 years) were treated. Most had diabetes (80%), hypertension (70%), and hyperlipidemia (80%). Pre‐procedural ankle‐brachial index (ABI) averaged 0.50 ± 0.14. Angiographic analysis showed 60% of lesions in the femoral artery and 40% as chronic total occlusions. No major adverse events occurred, with 100% technical success. Post‐procedural ABI improved to 0.92 ± 0.12 ( p < 0.05). At 6 months, the primary patency rate was 100%, with no clinically‐driven revascularization or adverse cardiovascular events. Mortality was 0%. All patients reported significant improvement in symptoms and walking distance, as well as enhanced quality of life and reduced pain during physical activity. The novel atherectomy device showed promising safety and efficacy for treating calcified LEAD. Larger‐scale trials are needed to confirm these outcomes.

Subjects

MeSH terms (MEDLINE)

AtherectomyPeripheral Arterial DiseasePlaque, AtheroscleroticHumansMaleMiddle AgedAgedProspective StudiesTreatment OutcomeAged, 80 and overAnkle Brachial IndexAdultFemaleFemoral ArteryLower ExtremityAngiographyFeasibility StudiesVascular Patency

Author keywords

FIMatherectomyendovascularlower extremity atherosclerosis diseaseperipheral arterial disease

Authors and institutions

  • Department of Vascular Surgery, Xuanwu Hospital, Capital Medical University, Beijing, China.

ORCID profiles: Yongquan Gu, Jianming Guo

Funding

  • Beijing Municipal Science & Technology Commission

Cite

APA

Wang, H., Pan, D., Cui, S., Tong, Z., Gao, X., Gu, Y., Guo, J., & Guo, L. (2025). First‐in‐Man Study of a Novel Peripheral Plaque Atherectomy Device. The Journal of Clinical Hypertension. https://doi.org/10.1111/jch.14967

Vancouver

Wang H, Pan D, Cui S, Tong Z, Gao X, Gu Y, et al. First‐in‐Man Study of a Novel Peripheral Plaque Atherectomy Device. The Journal of Clinical Hypertension. 2025. doi:10.1111/jch.14967

BibTeX
@article{Wang2025,
  author = {Wang, Hui and Pan, Dikang and Cui, Shijun and Tong, Zhu and Gao, Xixiang and Gu, Yongquan and Guo, Jianming and Guo, Lianrui},
  title = {First‐in‐Man Study of a Novel Peripheral Plaque Atherectomy Device},
  journal = {The Journal of Clinical Hypertension},
  year = {2025},
  doi = {10.1111/jch.14967}
}
Start for free →