Characteristics of Atrial Tachycardia Recurrence After Pulsed Field Ablation: Insights From Repeat Ablation Procedures
Journal of Cardiovascular Electrophysiology · 2026
DOI: 10.1111/jce.70487 ↗Kurz gefasst
Vergleichsstudie in der Zeitschrift Journal of Cardiovascular Electrophysiology, 2026. Verfasst von Kohei Ukita und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Rhythmology, University Heart Center, University Hospital Schleswig-Holstein, Lübeck, Germany. Hauptthemen laut MEDLINE: Pulmonary Veins, Atrial Fibrillation, Catheter Ablation, Tachycardia, Supraventricular. Die Arbeit nennt 13 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Background
Pulmonary vein isolation (PVI) using pulsed field ablation (PFA) for atrial fibrillation (AF) is becoming increasingly widespread. However, characteristics of atrial tachycardia (AT) recurrence after PFA remain unclear. We aimed to investigate characteristics of AT recurrence in comparison with AF recurrence after PFA‐based PVI.
Methods
We analyzed 60 consecutive patients who underwent repeat ablation for recurrent atrial tachyarrhythmia after initial PVI alone performed with a pentaspline PFA system. Patients were classified into an AT group (at least one AT episode before repeat ablation) and an AF group (AF recurrence only). Baseline characteristics, pulmonary vein (PV) reconnections, and recurrence‐free rate after repeat ablation procedure were assessed.
Results
The AT group consisted of 34 patients (57%). In the multivariate analysis, absence of PV reconnections was independently associated with AT recurrence ( p = 0.037). All mappable ATs were macro‐reentrant circuits and none were directly related to PVs. Recurrence‐free rate after repeat ablation did not differ between AT and AF groups ( p = 0.277). However, patients presenting in AT at the beginning of the repeat procedure had the most favorable outcomes, whereas those in AF had the poorest ( p = 0.042).
Conclusions
After PFA‐based PVI, AT recurrence was characterized by lower PV reconnection rates and macro‐reentrant circuits remote from the PVs, whereas AF recurrence was more frequently associated with PV reconnections. While overall outcomes after repeat ablation were comparable, baseline rhythm at the repeat procedure was associated with prognosis, underscoring the importance of tailored mapping and ablation strategies after PFA.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Rhythmology, University Heart Center, University Hospital Schleswig-Holstein, Lübeck, Germany.
ORCID-Profile: Kohei Ukita
Zitieren
APA
Ukita, K., Mamaev, R., Hatahet, S., Wenzel, J. P., Eitel, C., Kuck, K. H., & Tilz, R. R. (2026). Characteristics of Atrial Tachycardia Recurrence After Pulsed Field Ablation: Insights From Repeat Ablation Procedures. Journal of Cardiovascular Electrophysiology. https://doi.org/10.1111/jce.70487
Vancouver
Ukita K, Mamaev R, Hatahet S, Wenzel JP, Eitel C, Kuck KH, et al. Characteristics of Atrial Tachycardia Recurrence After Pulsed Field Ablation: Insights From Repeat Ablation Procedures. Journal of Cardiovascular Electrophysiology. 2026. doi:10.1111/jce.70487
BibTeX
@article{Ukita2026,
author = {Ukita, Kohei and Mamaev, Roman and Hatahet, Sascha and Wenzel, Jan-Per and Eitel, Charlotte and Kuck, Karl-Heinz and Tilz, Roland Richard},
title = {Characteristics of Atrial Tachycardia Recurrence After Pulsed Field Ablation: Insights From Repeat Ablation Procedures},
journal = {Journal of Cardiovascular Electrophysiology},
year = {2026},
doi = {10.1111/jce.70487}
}