Efficacy and Safety of Pulsed Field Ablation During Repeat Procedures for Treatment of Recurrent Atrial Arrhythmias After Pulmonary Vein Isolation
Journal of Cardiovascular Electrophysiology · 2026-11 · 37 (11) · 2541-2551
DOI: 10.1111/jce.70458 ↗Kurz gefasst
Vergleichsstudie in der Zeitschrift Journal of Cardiovascular Electrophysiology, online erschienen am 23.07.2026. Verfasst von Hiroshi Miyama und 9 weiteren Autor:innen. Beteiligte Einrichtung: Department of Medicine, Division of Cardiology Weill Cornell Medicine, New York, New York, USA. Hauptthemen laut MEDLINE: Pulmonary Veins, Atrial Fibrillation, Catheter Ablation. Die Arbeit nennt 36 Literaturangaben.
Abstract (Originalsprache)
Background
Little is known about the efficacy and safety of pulsed field ablation (PFA) for repeat ablation procedures for patients with recurrent atrial fibrillation (AF) after pulmonary vein (PV) isolation.
Objective
The purpose of this study was to evaluate and compare the efficacy and safety of PFA using a pentaspline ablation catheter with radiofrequency ablation (RFA) in repeat ablation procedures for atrial arrhythmia.
Methods
We compared 320 patients (mean age 71 ± 11 years, 61% male) who underwent repeat ablation procedures with PFA and RFA. Procedural data, including lesion set‐specific acute success, safety endpoints, and recurrence of atrial arrhythmia were compared between groups.
Results
Overall, 200 and 120 patients were treated with PFA and RFA during repeat ablation, respectively. Although the rate of baseline PV reconnection was comparable between groups, PV, posterior wall, and superior vena cava ablation were targeted in significantly more patients in the PFA group compared to the RFA group. In the PFA group, PV, posterior wall, and superior vena cava isolation were successfully achieved by PFA alone in 100% cases. Adjunctive RFA was required in 31% of anterior wall and 50% of lateral mitral isthmus PFA cases to achieve line of block. Procedure times were significantly shorter in the PFA group. Major complication rates were comparable between the groups (PFA vs. RFA, 0% vs. 1.7%, p = 0.067). Freedom from atrial arrhythmia recurrence at 1 year was similar between PFA and RFA groups (59% vs. 56%; log‐rank p = 0.71).
Conclusion
Use of PFA with a pentaspline catheter for repeat AF ablation was associated with more extensive ablation compared to RFA with low complication rates but did not result in increased freedom from AF recurrence.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Medicine, Division of Cardiology Weill Cornell Medicine, New York, New York, USA.
ORCID-Profile: James E Ip, George Thomas, Jim W Cheung
Zitieren
APA
Miyama, H., McCoy, S., Lam, M. C., Ip, J. E., Goljo, E., Thomas, G., Liu, C. F., Markowitz, S. M., Lerman, B. B., & Cheung, J. W. (2026). Efficacy and Safety of Pulsed Field Ablation During Repeat Procedures for Treatment of Recurrent Atrial Arrhythmias After Pulmonary Vein Isolation. Journal of Cardiovascular Electrophysiology, 37(11), 2541-2551. https://doi.org/10.1111/jce.70458
Vancouver
Miyama H, McCoy S, Lam MC, Ip JE, Goljo E, Thomas G, et al. Efficacy and Safety of Pulsed Field Ablation During Repeat Procedures for Treatment of Recurrent Atrial Arrhythmias After Pulmonary Vein Isolation. Journal of Cardiovascular Electrophysiology. 2026;37(11):2541-2551. doi:10.1111/jce.70458
BibTeX
@article{Miyama2026,
author = {Miyama, Hiroshi and McCoy, Sean and Lam, Matthew C and Ip, James E and Goljo, Erden and Thomas, George and Liu, Christopher F and Markowitz, Steven M and Lerman, Bruce B and Cheung, Jim W},
title = {Efficacy and Safety of Pulsed Field Ablation During Repeat Procedures for Treatment of Recurrent Atrial Arrhythmias After Pulmonary Vein Isolation},
journal = {Journal of Cardiovascular Electrophysiology},
year = {2026},
volume = {37},
number = {11},
pages = {2541--2551},
doi = {10.1111/jce.70458}
}
EUVIMED