Comparison of Spatio‐Temporal Dispersion Electrogram Ablation and Low Voltage Zone Ablation in Patients With Persistent Atrial Fibrillation
Journal of Cardiovascular Electrophysiology · 2026-08 · 37 (8) · 1837-1845
DOI: 10.1111/jce.70413 ↗At a glance
Vergleichsstudie in Journal of Cardiovascular Electrophysiology, published online on 2026-06-28. Written by Yutaro Kaneko and 6 co-authors. Institution: Division of Cardiology, Department of Internal Medicine III, Hamamatsu University School of Medicine, Hamamatsu, Japan. Major MEDLINE topics: Atrial Fibrillation, Catheter Ablation, Electrophysiologic Techniques, Cardiac, Pulmonary Veins. 16 references. The full text is freely available (open access, CC BY-NC 4.0).
Abstract (original language)
Background
Pulmonary vein isolation (PVI) alone was less effective for patients with persistent atrial fibrillation (AF) compared to those with paroxysmal AF. Although the TAILORED AF trial demonstrated the efficacy of spatio‐temporal dispersion electrogram (STDE) ablation as additional treatment for PVI, comparisons between STDE and low‐voltage zone (LVZ) remain unclear. We compared the efficacy of two different methods beyond PVI: the STDE and the LVZ ablation.
Methods
This retrospective observational study included 107 consecutive patients (median age, 71 years; 79 male) who underwent initial catheter ablation for persistent AF at our institution. STDE evaluation and STDE‐guided substrate modification were performed in the STDE ablation group ( n = 53). The historical control group ( n = 54) did not undergo STDE evaluation and received additional ablation based on the LVZ. The primary endpoint was the recurrence of atrial arrhythmias after the ablation up to 24 months, with a 3‐month blanking period applied.
Results
The number of additional ablations, including linear ablation, posterior wall isolation, and focal ablation, was significantly higher in the STDE group. The AF‐free survival rate at 24 months follow‐up after ablation was higher in the STDE group (76.3% vs. 58.4%; p = 0.027). In the multivariate Cox proportional regression analysis, prolonged AF duration (hazard ratio [HR] 1.37, 95% confidence interval [CI] 1.16–1.61; p < 0.001) and larger left atrial size (HR: 1.11, 95% CI: 1.02–1.20; p = 0.012) were independent predictors of AF recurrence. Conversely, STDE ablation was independently associated with a significantly lower risk of recurrence (HR: 0.29, 95% CI: 0.12–0.66; p = 0.004).
Conclusion
STDE was associated with a lower risk of AF recurrence than PVI with LVZ ablation.
Subjects
MeSH terms (MEDLINE)
Author keywords
Authors and institutions
- Division of Cardiology, Department of Internal Medicine III, Hamamatsu University School of Medicine, Hamamatsu, Japan.
ORCID profiles: Yutaro Kaneko, Yoshihisa Naruse, Yuki Tokonami, Kazuki Ito, Taro Narumi, Makoto Sano, Yuichiro Maekawa
Cite
APA
Kaneko, Y., Naruse, Y., Tokonami, Y., Ito, K., Narumi, T., Sano, M., & Maekawa, Y. (2026). Comparison of Spatio‐Temporal Dispersion Electrogram Ablation and Low Voltage Zone Ablation in Patients With Persistent Atrial Fibrillation. Journal of Cardiovascular Electrophysiology, 37(8), 1837-1845. https://doi.org/10.1111/jce.70413
Vancouver
Kaneko Y, Naruse Y, Tokonami Y, Ito K, Narumi T, Sano M, et al. Comparison of Spatio‐Temporal Dispersion Electrogram Ablation and Low Voltage Zone Ablation in Patients With Persistent Atrial Fibrillation. Journal of Cardiovascular Electrophysiology. 2026;37(8):1837-1845. doi:10.1111/jce.70413
BibTeX
@article{Kaneko2026,
author = {Kaneko, Yutaro and Naruse, Yoshihisa and Tokonami, Yuki and Ito, Kazuki and Narumi, Taro and Sano, Makoto and Maekawa, Yuichiro},
title = {Comparison of Spatio‐Temporal Dispersion Electrogram Ablation and Low Voltage Zone Ablation in Patients With Persistent Atrial Fibrillation},
journal = {Journal of Cardiovascular Electrophysiology},
year = {2026},
volume = {37},
number = {8},
pages = {1837--1845},
doi = {10.1111/jce.70413}
}
EUVIMED