Incidence and Outcomes of Early Pacemaker Implantation for Sinus Node Dysfunction Following Atrial Fibrillation Ablation
Journal of Cardiovascular Electrophysiology · 2026-07 · 37 (7) · 1457-1464
DOI: 10.1111/jce.70365 ↗Kurz gefasst
Multizentrische Studie in der Zeitschrift Journal of Cardiovascular Electrophysiology, online erschienen am 15.05.2026. Verfasst von Jiaqi Mi und 12 weiteren Autor:innen. Beteiligte Einrichtung: Kansas City Heart Rhythm Institute, Overland Park, Kansas, USA. Hauptthemen laut MEDLINE: Atrial Fibrillation, Sick Sinus Syndrome, Pacemaker, Artificial, Catheter Ablation. Die Arbeit nennt 21 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar.
Abstract (Originalsprache)
Introduction
Sinus node dysfunction (SND) may be observed following atrial fibrillation ablation (AFA), leading to urgent pacemaker (PPM) implantation. However, the incidence of PPM implantation and the long‐term outcomes are not well known.
Objective
To assess the incidence and outcomes of PPM implantation for SND immediately after AFA and assess the long‐term requirement for pacing.
Methods
We conducted a multi‐center, retrospective study of patients who underwent AFA from 2018 to 2024 and received PPM for SND during the same hospitalization. We assessed the patient and procedural characteristics, post‐PPM complications, and atrial pacing percentage (AP%) at 30 and 90 days.
Results
Of the 8772 patients who underwent AFA, 178 patients (2.0%) received PPM implantation for SND during the same admission. The mean age was 78.6 ± 6.0 years; 48.3% were female, and 51.9% had non‐paroxysmal atrial fibrillation; 14.6% required temporary pacing. PPM implantation was associated with complications, including pocket hematoma (10.7%) and lead malfunction (1.2%). One patient required PPM explantation for pocket erosion following pocket hematoma. At 30 days, 33.1% of patients had AP > 50% with a mean AP% of 34.1 ± 39.2%. At 90 days, 31.5% patients had AP > 50% with a mean AP% of 33.7 ± 39.0%, and 6.7% were PPM‐dependent.
Conclusions
While the incidence of PPM implantation for Sinus node dysfunction immediately following atrial fibrillation ablation is low, it is associated with an increased risk of complications, especially pocket hematoma. The need for atrial pacing decreased during follow‐up. Hence, extending the monitoring period must be considered before PPM implantation.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Kansas City Heart Rhythm Institute, Overland Park, Kansas, USA.
- Texas Cardiac Arrhythmia Institute, Austin, Texas, USA.
ORCID-Profile: Jiaqi Mi, Naga Venkata K Pothineni, Scott Koerber, Sanghamitra Mohanty
Zitieren
APA
Mi, J., Katapadi, A., Herink, E., Darden, D., Pothineni, N. V. K., Park, P., Koerber, S., Gopinathannair, R., Tummala, R., Mohanty, S., Natale, A., Lakkireddy, D., & Kabra, R. (2026). Incidence and Outcomes of Early Pacemaker Implantation for Sinus Node Dysfunction Following Atrial Fibrillation Ablation. Journal of Cardiovascular Electrophysiology, 37(7), 1457-1464. https://doi.org/10.1111/jce.70365
Vancouver
Mi J, Katapadi A, Herink E, Darden D, Pothineni NVK, Park P, et al. Incidence and Outcomes of Early Pacemaker Implantation for Sinus Node Dysfunction Following Atrial Fibrillation Ablation. Journal of Cardiovascular Electrophysiology. 2026;37(7):1457-1464. doi:10.1111/jce.70365
BibTeX
@article{Mi2026,
author = {Mi, Jiaqi and Katapadi, Aashish and Herink, Eli and Darden, Douglas and Pothineni, Naga Venkata K and Park, Peter and Koerber, Scott and Gopinathannair, Rakesh and Tummala, Rangarao and Mohanty, Sanghamitra and Natale, Andrea and Lakkireddy, Dhanunjaya and Kabra, Rajesh},
title = {Incidence and Outcomes of Early Pacemaker Implantation for Sinus Node Dysfunction Following Atrial Fibrillation Ablation},
journal = {Journal of Cardiovascular Electrophysiology},
year = {2026},
volume = {37},
number = {7},
pages = {1457--1464},
doi = {10.1111/jce.70365}
}
EUVIMED