Vergleichsstudie in der Zeitschrift Journal of Interventional Cardiac Electrophysiology, 2024. Verfasst von Nazli Kubra Okumus und 6 weiteren Autor:innen. Beteiligte Einrichtung: Allegheny Health Network, Pittsburgh, PA, USA. Hauptthemen laut MEDLINE: Atrial Fibrillation, Pacemaker, Artificial, Sick Sinus Syndrome, Anti-Arrhythmia Agents. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 31 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Biosense Webster.
Abstract (Originalsprache)
Background
Sinus node dysfunction (SND) is commonly seen in patients with atrial fibrillation (AF). The purpose of this study was to compare the incidence of pacemaker implantation among patients with SND and AF treated with catheter ablation (CA) versus anti-arrhythmic drugs (AADs).
Methods
The 2013–2022 Optum Clinformatics database, an administrative claims database for commercially insured individuals in the United States (US), was used for this study. Patients with AF and SND and a history of at least one AAD prescription were identified and classified into CA or AAD cohorts based on subsequent treatment received. Inverse probability treatment weighting was applied to balance socio-demographic and clinical characteristics between the cohorts. Weighted Cox regression modeling was used to evaluate the differential risk of incident permanent pacemaker (PPM) implantation. Sub-analyses were performed by AF type (paroxysmal versus persistent).
Results
A total of 1206 patients in the AAD cohort and 1624 patients in the CA cohort were included. Study cohorts were well-balanced post-weighting. The incidence rate of PPM implantation (per 1000 person–year) was 55.8 for the CA cohort and 117.8 for the AAD cohort. Regression analysis demonstrated that the CA cohort had 42% lower risk of incident PPM implantation than those treated with AADs (hazard ratio [HR], 0.58; 95% CI, 0.46–0.72, p < 0.001). CA-treated patients had lower risks of PPM implantation versus AAD-treated patients among those with paroxysmal AF (HR, 0.48; 95% CI, 0.34–0.69, p < 0.001) and persistent AF (HR, 0.57; 95% CI, 0.40–0.81, p = 0.002).
Conclusions
Patients with AF and SND treated with CA have significantly lower risks of incident PPM implantation compared with those treated with an AAD. Graphical Abstract
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Allegheny Health Network, Pittsburgh, PA, USA.
- Dartmouth Health, The Dartmouth Institute, Lebanon, NH, USA.
- University of Toledo, Toledo, OH, USA.
- Franchise Health Economics and Market Access, Johnson & Johnson, Irvine, CA, USA.
- Medical Device Epidemiology and Real-World Data Sciences, Johnson & Johnson, New Brunswick, NJ, USA.
- Heart and Vascular Institute, MetroHealth Medical Center, Case Western Reserve University, 2500 MetroHealth Dr, Cleveland, OH, USA. skarim@metrohealth.org.
Förderung
- Biosense Webster
Zitieren
APA
Okumus, N. K., Zeitler, E. P., Moustafa, A., Iglesias, M., Khanna, R., Rong, Y., & Karim, S. (2024). Three-year incidence of pacemaker implantation in patients with atrial fibrillation and sinus node dysfunction receiving ablation versus antiarrhythmic drugs. Journal of Interventional Cardiac Electrophysiology. https://doi.org/10.1007/s10840-024-01790-2
Vancouver
Okumus NK, Zeitler EP, Moustafa A, Iglesias M, Khanna R, Rong Y, et al. Three-year incidence of pacemaker implantation in patients with atrial fibrillation and sinus node dysfunction receiving ablation versus antiarrhythmic drugs. Journal of Interventional Cardiac Electrophysiology. 2024. doi:10.1007/s10840-024-01790-2
BibTeX
@article{Okumus2024,
author = {Okumus, Nazli Kubra and Zeitler, Emily P and Moustafa, Abdelmoniem and Iglesias, Maximiliano and Khanna, Rahul and Rong, Yiran and Karim, Saima},
title = {Three-year incidence of pacemaker implantation in patients with atrial fibrillation and sinus node dysfunction receiving ablation versus antiarrhythmic drugs},
journal = {Journal of Interventional Cardiac Electrophysiology},
year = {2024},
doi = {10.1007/s10840-024-01790-2}
}
EUVIMED