Comparison of HEMOlysis Markers Among Three Pulsed Field Ablation Systems: HEMO‐PFA Study
Journal of Cardiovascular Electrophysiology · 2026
DOI: 10.1111/jce.70343 ↗Kurz gefasst
Vergleichsstudie in der Zeitschrift Journal of Cardiovascular Electrophysiology, 2026. Verfasst von Kazuhisa Matsumoto und 11 weiteren Autor:innen. Beteiligte Einrichtung: Department of Cardiology, Saitama Medical University, International Medical Center, Saitama, Japan. Hauptthemen laut MEDLINE: Hemolysis, Atrial Fibrillation, Catheter Ablation. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 29 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Background
Pulsed field ablation (PFA) has emerged as a novel non‐thermal modality for atrial fibrillation (AF) ablation. While hemolysis is a known complication of PFA, comparative data among different systems remain limited.
Methods
We prospectively enrolled 150 consecutive AF patients undergoing ablation with one of three PFA systems: FARAPULSE (FP), PulseSelect (PS), or VARIPULSE (VP) (50 cases each). Perioperative blood samples were collected pre‐procedure, immediately post‐procedure, and at 24 h. Hemolysis markers (LDH, LD2, indirect bilirubin, haptoglobin) and myocardial injury markers (CK, CK‐MB, troponin T) were measured. Procedural characteristics and complications were compared across the systems.
Results
Among 144 analyzed patients, VP was associated with the shortest procedure time (76 ± 27 min vs. FP 91 ± 25 min and PS 97 ± 26 min, p < 0.001) and fewest applications (23 ± 5 vs. FP 40 ± 6 and PS 56 ± 26, p < 0.001). Hemolysis markers increased in all systems, but the magnitude varied. ΔLDH was highest with FP (95.1 ± 49.4 U/L), intermediate with PS (62.6 ± 38.1 U/L), and lowest with VP (41.3 ± 26.7 U/L; p < 0.001). Haptoglobin decreased most with FP (ΔHp −56.5 ± 27.2 mg/dL), followed by VP (−41.7 ± 25.8 mg/dL) and PS (−28.3 ± 21.6 mg/dL; p < 0.001). Myocardial injury also differed: ΔTroponin T was lowest with VP (1545 ± 920 pg/mL vs. FP 2392 ± 1123 pg/mL and PS 2128 ± 1041 pg/mL, p = 0.002), with a similar trend for ΔCK (141 ± 92 U/L vs. 231 ± 138 U/L and 207 ± 119 U/L, p < 0.001). Complications included acute kidney injury in two FP cases and cardiac tamponade in one PS case.
Conclusions
Hemolysis and myocardial injury differ among PFA systems. FP was associated with the greatest changes, PS with the least hemolysis, and VP with the least myocardial injury. These differences may reflect variations in pulse output, electrode configuration, and tissue contact visualization.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Cardiology, Saitama Medical University, International Medical Center, Saitama, Japan.
ORCID-Profile: Wataru Sasaki, Masataka Narita, Hitoshi Mori, Kazuo Matsumoto, Ritsushi Kato
Zitieren
APA
Matsumoto, K., Matsumoto, K., Tanaka, N., Sasaki, W., Naganuma, T., Narita, M., Mori, H., Ikeda, Y., Arai, T., Nakano, S., Matsumoto, K., & Kato, R. (2026). Comparison of HEMOlysis Markers Among Three Pulsed Field Ablation Systems: HEMO‐PFA Study. Journal of Cardiovascular Electrophysiology. https://doi.org/10.1111/jce.70343
Vancouver
Matsumoto K, Matsumoto K, Tanaka N, Sasaki W, Naganuma T, Narita M, et al. Comparison of HEMOlysis Markers Among Three Pulsed Field Ablation Systems: HEMO‐PFA Study. Journal of Cardiovascular Electrophysiology. 2026. doi:10.1111/jce.70343
BibTeX
@article{Matsumoto2026,
author = {Matsumoto, Kazuhisa and Matsumoto, Kei and Tanaka, Naomichi and Sasaki, Wataru and Naganuma, Tsukasa and Narita, Masataka and Mori, Hitoshi and Ikeda, Yoshifumi and Arai, Takahide and Nakano, Shintaro and Matsumoto, Kazuo and Kato, Ritsushi},
title = {Comparison of HEMOlysis Markers Among Three Pulsed Field Ablation Systems: HEMO‐PFA Study},
journal = {Journal of Cardiovascular Electrophysiology},
year = {2026},
doi = {10.1111/jce.70343}
}
EUVIMED