EUVIMEDEUVIMED entdecken
Crossref

Pulsed Field Ablation in Atrial Fibrillation: First Reported Mexican Experience and Procedural Learning Curve

Rodrigo González Aguirre iD, Carlos Enrique Guzmán Rodríguez, José Raymundo Leal Díaz, Francisco Javier Valadez Molina, Silvia Melissa Galindo Garza, Nardia Isabel Ornelas Hernández, Jorge Emilio Leal Cavazos, Mauricio Cortés Aguirre

Journal of Cardiovascular Electrophysiology · 2026-04 · 37 (4) · 872-875

DOI: 10.1111/jce.70304 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Cardiovascular Electrophysiology, online erschienen am 23.02.2026. Verfasst von Rodrigo González Aguirre und 7 weiteren Autor:innen. Beteiligte Einrichtung: Department of Cardiology, Instituto de Seguridad y Servicios Sociales de los Trabajadores del Estado (ISSSTE), Hospital Regional de Monterrey, Monter…. Hauptthemen laut MEDLINE: Atrial Fibrillation, Learning Curve, Pulmonary Veins, Clinical Competence. Die Arbeit nennt 11 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Pulsed field ablation (PFA) is a novel non‐thermal modality for atrial fibrillation (AF) ablation that selectively targets myocardial tissue while minimizing collateral injury. While widely reported in Europe and the United States, data from Latin America remain scarce.

Methods

We present the first four cases of PFA performed in Monterrey, Mexico. All procedures were conducted with ultrasound‐guided femoral venous access, transseptal puncture using FastCath SL1 and Brockenbrough needle guided with intracardiac echocardiography, mapping with pentaray catheter, and ablation with a PulsedSelect PFA catheter via a FlexCath sheath. Antral pulmonary vein isolation was the primary endpoint, with posterior wall ablation performed at operator discretion.

Results

Pulmonary vein isolation was achieved in all patients. Two patients underwent posterior wall ablation. Isthmus measurements were obtained only in patients who underwent pulmonary vein isolation alone, with posterior isthmus lengths of 16.9 mm and 12 mm. Three patients maintained sinus rhythm throughout the procedure; one patient with a common right pulmonary vein trunk and an enlarged left atrial volume index (LAVI) developed intraprocedural AF requiring electrical cardioversion. Mean procedure time was 149 min (range 105–220), and mean fluoroscopy time was 22 min (range 14–27). No complications occurred.

Conclusions

This first Mexican experience demonstrates that PFA is feasible and safe, with reproducible pulmonary vein isolation and a short procedural learning curve. These findings align with international reports and support the integration of PFA into AF ablation strategies in Latin America.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Atrial FibrillationLearning CurvePulmonary VeinsClinical CompetenceCatheter AblationHumansTreatment OutcomeMiddle AgedMaleMexicoFemaleAgedTime FactorsIrreversible Electroporation TherapyAction PotentialsHeart RateElectrophysiologic Techniques, Cardiac

Stichwörter der Autor:innen

Mexicoatrial fibrillationcatheter ablationelectrophysiologylearning curvepulsed electric field ablation

Autor:innen und Institutionen

  • Department of Cardiology, Instituto de Seguridad y Servicios Sociales de los Trabajadores del Estado (ISSSTE), Hospital Regional de Monterrey, Monterrey, Nuevo León, México.
  • Department of Cardiology, Hospital Universitario Dr. José Eleuterio González, Monterrey, Nuevo León, México.
  • Department of Cardiology, Instituto de Seguridad y Servicios Sociales de los Trabajadores del Estado (ISSSTE), Hospital Regional de Alta Especialidad de Torreón, Torreón, Coahuila, México.
  • Department of Cardiology, Instituto de Seguridad y Servicios Sociales de los Trabajadores del Estado (ISSSTE), Hospital General de Saltillo, Saltillo, Coahuila, México.

ORCID-Profile: Rodrigo González Aguirre

Zitieren

APA

Aguirre, R. G., Rodríguez, C. E. G., Díaz, J. R. L., Molina, F. J. V., Garza, S. M. G., Hernández, N. I. O., Cavazos, J. E. L., & Aguirre, M. C. (2026). Pulsed Field Ablation in Atrial Fibrillation: First Reported Mexican Experience and Procedural Learning Curve. Journal of Cardiovascular Electrophysiology, 37(4), 872-875. https://doi.org/10.1111/jce.70304

Vancouver

Aguirre RG, Rodríguez CEG, Díaz JRL, Molina FJV, Garza SMG, Hernández NIO, et al. Pulsed Field Ablation in Atrial Fibrillation: First Reported Mexican Experience and Procedural Learning Curve. Journal of Cardiovascular Electrophysiology. 2026;37(4):872-875. doi:10.1111/jce.70304

BibTeX
@article{Aguirre2026,
  author = {Aguirre, Rodrigo González and Rodríguez, Carlos Enrique Guzmán and Díaz, José Raymundo Leal and Molina, Francisco Javier Valadez and Garza, Silvia Melissa Galindo and Hernández, Nardia Isabel Ornelas and Cavazos, Jorge Emilio Leal and Aguirre, Mauricio Cortés},
  title = {Pulsed Field Ablation in Atrial Fibrillation: First Reported Mexican Experience and Procedural Learning Curve},
  journal = {Journal of Cardiovascular Electrophysiology},
  year = {2026},
  volume = {37},
  number = {4},
  pages = {872--875},
  doi = {10.1111/jce.70304}
}
Kostenlos starten →