EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Consistency of ablations with trainee and increasing independence during fellowship training—Analysis of ablation data by CARTONET

John Whitaker iD, Tina D Hunter iD, Jane Carsey, William H Thatcher, Don Yungher, Stanislav Goldberg, Christina Kaneko, Mati Amit, Omar Kreidieh iD, Clinton Thurber, Nathaniel Steiger, David Chang iD und 9 weitere

Journal of Cardiovascular Electrophysiology · 2024

DOI: 10.1111/jce.16349 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Cardiovascular Electrophysiology, 2024. Verfasst von John Whitaker und 20 weiteren Autor:innen. Beteiligte Einrichtung: School of Biomedical Engineering and Imaging Sciences, King's College, London, UK. Hauptthemen laut MEDLINE: Catheter Ablation, Clinical Competence, Atrial Fibrillation, Education, Medical, Graduate. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 21 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Biosense Webster.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Introduction

Training in clinical cardiac electrophysiology (CCEP) involves the development of catheter handling skills to safely deliver effective treatment. Objective data from analysis of ablation data for evaluating trainee of CCEP procedures has not previously been possible. Using the artificial intelligence cloud‐based system (CARTONET), we assessed the impact of trainee progress through ablation procedural quality.

Methods

Lesion‐ and procedure‐level data from all de novo atrial fibrillation (AF) and cavotricuspid isthmus (CTI) ablations involving first‐year (Y1) or second‐year (Y2) fellows across a full year of fellowship was curated within Cartonet. Lesions were automatically assigned to anatomic locations.

Results

Lesion characteristics, including contact force, catheter stability, impedance drop, ablation index value, and interlesion time/distance were similar over each training year. Anatomic location and supervising operator significantly affected catheter stability. The proportion of lesion sets delivered independently and of lesions delivered by the trainee increased steadily from the first quartile of Y1 to the last quartile of Y2. Trainee perception of difficult regions did not correspond to objective measures.

Conclusion

Objective ablation data from Cartonet showed that the progression of trainees through CCEP training does not impact lesion‐level measures of treatment efficacy (i.e., catheter stability, impedance drop). Data demonstrates increasing independence over a training fellowship. Analyses like these could be useful to inform individualized training programs and to track trainee's progress. It may also be a useful quality assurance tool for ensuring ongoing consistency of treatment delivered within training institutions.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Catheter AblationClinical CompetenceAtrial FibrillationEducation, Medical, GraduateHumansLearning CurveElectrophysiologic Techniques, CardiacArtificial IntelligenceTime FactorsTreatment OutcomeFellowships and ScholarshipsCardiologistsCardiac ElectrophysiologyCardiac Catheters

Stichwörter der Autor:innen

Cartonetartificial intelligenceclinical cardiac electrophysiology trainingquality assurance and patient safety

Autor:innen und Institutionen

  • School of Biomedical Engineering and Imaging Sciences, King's College, London, UK.
  • CTI Clinical Trial & Consulting, Covington, Kentucky, USA.
  • Biosense Webster, Irvine, California, USA.
  • Brigham and Women's Hospital and Harvard Medical School, Boston, Massachusetts, USA.

ORCID-Profile: John Whitaker, Tina D Hunter, Omar Kreidieh, David Chang, Esseim Sharma, Sunil Kapur, William H Sauer, Bruce Koplan, Paul C Zei

Förderung

  • Biosense Webster

Zitieren

APA

Whitaker, J., Hunter, T. D., Carsey, J., Thatcher, W. H., Yungher, D., Goldberg, S., Kaneko, C., Amit, M., Kreidieh, O., Thurber, C., Steiger, N., Chang, D., Batnyam, U., Sharma, E., McClennen, S., Kapur, S., Tadros, T., Sauer, W. H., Koplan, B., …, & Zei, P. C. (2024). Consistency of ablations with trainee and increasing independence during fellowship training—Analysis of ablation data by CARTONET. Journal of Cardiovascular Electrophysiology. https://doi.org/10.1111/jce.16349

Vancouver

Whitaker J, Hunter TD, Carsey J, Thatcher WH, Yungher D, Goldberg S, et al. Consistency of ablations with trainee and increasing independence during fellowship training—Analysis of ablation data by CARTONET. Journal of Cardiovascular Electrophysiology. 2024. doi:10.1111/jce.16349

BibTeX
@article{Whitaker2024,
  author = {Whitaker, John and Hunter, Tina D and Carsey, Jane and Thatcher, William H and Yungher, Don and Goldberg, Stanislav and Kaneko, Christina and Amit, Mati and Kreidieh, Omar and Thurber, Clinton and Steiger, Nathaniel and Chang, David and Batnyam, Uyanga and Sharma, Esseim and McClennen, Seth and Kapur, Sunil and Tadros, Thomas and Sauer, William H and Koplan, Bruce and Tedrow, Usha and Zei, Paul C},
  title = {Consistency of ablations with trainee and increasing independence during fellowship training—Analysis of ablation data by CARTONET},
  journal = {Journal of Cardiovascular Electrophysiology},
  year = {2024},
  doi = {10.1111/jce.16349}
}
Kostenlos starten →