EUVIMEDOpdag EUVIMED
Open access · CC BY 4.0

Intravascular Lithotripsy to Facilitate Extraction of Very Old Cardiac Implantable Electronic Devices Leads

Jamie Kowal iD, Travis Richardson iD, George H Crossley

Journal of Cardiovascular Electrophysiology · 2026

DOI: 10.1111/jce.70280 ↗

At a glance

Journal article in Journal of Cardiovascular Electrophysiology, 2026. Written by Jamie Kowal and 2 co-authors. Institution: Department of Cardiovascular Diseases, Vanderbilt University, Nashville, Tennessee, USA. Major MEDLINE topics: Device Lead Extraction, Lithotripsy, Pacemaker, Artificial, Defibrillators, Implantable. 19 references. The full text is freely available (open access, CC BY 4.0).

AbstractSubjectsBibliografiske oplysningerCiteRelated studies

Abstract (original language)

Background

One of the challenges encountered when extracting transvenous leads with long dwell times is the presence of dense calcifications encasing the leads. This is the most likely reason for failure to advance a laser extraction sheath. The Shockwave intravascular lithotripsy (IVL) device is an angioplasty balloon that delivers intravascular lithotripsy and fractures calcified lesions in the vasculature, approved for use in coronary and arterial angioplasty. It has also been reported as an adjunctive tool in transvenous lead extraction.

Objective

To report the Vanderbilt University Medical Center experience using Shockwave(r) Lithotripsy in the extraction of very old leads.

Methods

We report procedural outcomes in this retrospective single‐center series of 24 patients in whom IVL was performed for pretreatment before lead extraction. To use the shockwave balloon, one must have venous access along the path of the leads. In some cases, there was venous access, and in others, a lower‐risk lead was extracted first to allow for the passage of the Shockwave balloon. After IVL pretreatment, leads were extracted using conventional laser and, when necessary, mechanical tools.

Results

Forty‐nine total leads were extracted, with a median of 2 leads per patient and median dwell time of 16 years with a range of 4–36 years. All transvenous leads were successfully removed, and there were no significant complications. An excimer laser system (Philips, Inc.) was utilized for extraction in all cases, with a median sheath size of 14 Fr. Despite long dwell times, mechanical extraction tools were only required in 6 (12%) of the leads.

Conclusion

Our experience contributes to the growing body of data supporting the use of Shockwave IVL as an adjunctive measure during extraction of calcified leads with long dwell time.

Subjects

MeSH terms (MEDLINE)

Device Lead ExtractionLithotripsyPacemaker, ArtificialDefibrillators, ImplantableDevice RemovalCalcinosisHumansRetrospective StudiesTreatment OutcomeFemaleMaleAgedTime FactorsAged, 80 and over

Author keywords

intravascular lithotripsylead extraction

Authors and institutions

  • Department of Cardiovascular Diseases, Vanderbilt University, Nashville, Tennessee, USA.
  • Vanderbilt Heart and Vascular Institute, Vanderbilt University Medical Center, Nashville, Tennessee, USA.

ORCID profiles: Jamie Kowal, Travis Richardson

Cite

APA

Kowal, J., Richardson, T., & Crossley, G. H. (2026). Intravascular Lithotripsy to Facilitate Extraction of Very Old Cardiac Implantable Electronic Devices Leads. Journal of Cardiovascular Electrophysiology. https://doi.org/10.1111/jce.70280

Vancouver

Kowal J, Richardson T, Crossley GH. Intravascular Lithotripsy to Facilitate Extraction of Very Old Cardiac Implantable Electronic Devices Leads. Journal of Cardiovascular Electrophysiology. 2026. doi:10.1111/jce.70280

BibTeX
@article{Kowal2026,
  author = {Kowal, Jamie and Richardson, Travis and Crossley, George H},
  title = {Intravascular Lithotripsy to Facilitate Extraction of Very Old Cardiac Implantable Electronic Devices Leads},
  journal = {Journal of Cardiovascular Electrophysiology},
  year = {2026},
  doi = {10.1111/jce.70280}
}
Start for free →