EUVIMEDOpdag EUVIMED
Validierungsstudie

Validation of a Digital Twin Model for Three‐Dimensional Noninvasive Functional Substrate Prediction in Scar Related Ventricular Tachycardia

Matteo Parollo iD, Niccolò Biasi, Marco Torre, Lorenzo Pistelli iD, Federico Fiorentini, Mario Giannotti Santoro, Antonio Canu, Raffaele De Lucia, Gino Grifoni, Andrea Di Cori iD, Luca Segreti iD, Alessandro Tognetti and 1 more

Journal of Cardiovascular Electrophysiology · 2026

DOI: 10.1111/jce.70184 ↗

At a glance

Validierungsstudie in Journal of Cardiovascular Electrophysiology, 2026. Written by Matteo Parollo and 12 co-authors. Institution: Second Division of Cardiology, Cardiothoracic and Vascular Department, Pisa University Hospital, Pisa, Italy. Major MEDLINE topics: Tachycardia, Ventricular, Cicatrix, Electrophysiologic Techniques, Cardiac, Action Potentials. 27 references. Funded by: This study was supported by 'Regione Toscana' through Bando Ricerca Salute 2018: a regional public call for research and development projects aimed at supporti….

AbstractSubjectsBibliografiske oplysningerCiteRelated studies

Abstract (original language)

Background

High density electroanatomical mapping (EAM) is the standard for identifying functional substrate in scar‐related ventricular tachycardia (VT), but it is limited by its two‐dimensional nature and increased procedural complexity. Imaging‐based strategies provide anatomical characterization but lack functional information. We evaluated a novel digital twin model (CardioMat) to non‐invasively predict functional substrate in three‐dimensions.

Objective

To validate a novel digital twin model for noninvasive prediction of functional substrate in scar‐related ventricular tachycardia.

Methods

Fifteen patients with ischemic or nonischemic cardiomyopathy undergoing VT ablation were retrospectively analyzed. High‐density EAM, cardiac magnetic resonance (CMR) post‐processing with ADAS3D, and CardioMat modeling were performed. CardioMat‐generated three‐dimensional activation maps were integrated into the CARTO EAM suite. Deceleration zones (DZs) identified by CardioMat were compared with EAM‐derived DZs and CMR‐based heterogeneous tissue channels (HTCs) and scar areas.

Results

A total of 255 cardiac segments were analyzed. CardioMat‐derived DZs demonstrated high diagnostic accuracy (79% sensitivity, 93% specificity, 81% PPV, 92% NPV, 89% accuracy) for predicting EAM‐DZ localization, outperforming CMR scar and HTCs. Multivariate analysis confirmed CardioMat DZs are the strongest independent predictor of EAM‐DZ localization (OR 17.4, 95% CI 6.9–43.8, p > 0.001).

Conclusions

This study provides preliminary evidence supporting the feasibility of a digital twin model for noninvasive functional substrate characterization. CardioMat integrates anatomical and functional information, outperforming conventional CMR‐based assessment. Prospective multicenter validation is needed to establish its role in VT ablation guidance.

Subjects

MeSH terms (MEDLINE)

Tachycardia, VentricularCicatrixElectrophysiologic Techniques, CardiacAction PotentialsModels, CardiovascularCardiomyopathiesImaging, Three-DimensionalHumansMaleFemaleMiddle AgedRetrospective StudiesPredictive Value of TestsReproducibility of ResultsAgedCatheter AblationHeart Rate

Author keywords

cardiac magnetic resonancedigital twin modelingelectroanatomic mappingfunctional substrate mappingsubstrate‐based ablationventricular tachycardiaventricular tachycardia

Authors and institutions

  • Second Division of Cardiology, Cardiothoracic and Vascular Department, Pisa University Hospital, Pisa, Italy.
  • Information Engineering Department, University of Pisa, Pisa, Italy.

ORCID profiles: Matteo Parollo, Lorenzo Pistelli, Andrea Di Cori, Luca Segreti, Giulio Zucchelli

Funding

  • This study was supported by 'Regione Toscana' through Bando Ricerca Salute 2018: a regional public call for research and development projects aimed at supporti…

Cite

APA

Parollo, M., Biasi, N., Torre, M., Pistelli, L., Fiorentini, F., Santoro, M. G., Canu, A., De Lucia, R., Grifoni, G., Di Cori, A., Segreti, L., Tognetti, A., & Zucchelli, G. (2026). Validation of a Digital Twin Model for Three‐Dimensional Noninvasive Functional Substrate Prediction in Scar Related Ventricular Tachycardia. Journal of Cardiovascular Electrophysiology. https://doi.org/10.1111/jce.70184

Vancouver

Parollo M, Biasi N, Torre M, Pistelli L, Fiorentini F, Santoro MG, et al. Validation of a Digital Twin Model for Three‐Dimensional Noninvasive Functional Substrate Prediction in Scar Related Ventricular Tachycardia. Journal of Cardiovascular Electrophysiology. 2026. doi:10.1111/jce.70184

BibTeX
@article{Parollo2026,
  author = {Parollo, Matteo and Biasi, Niccolò and Torre, Marco and Pistelli, Lorenzo and Fiorentini, Federico and Santoro, Mario Giannotti and Canu, Antonio and De Lucia, Raffaele and Grifoni, Gino and Di Cori, Andrea and Segreti, Luca and Tognetti, Alessandro and Zucchelli, Giulio},
  title = {Validation of a Digital Twin Model for Three‐Dimensional Noninvasive Functional Substrate Prediction in Scar Related Ventricular Tachycardia},
  journal = {Journal of Cardiovascular Electrophysiology},
  year = {2026},
  doi = {10.1111/jce.70184}
}
Start for free →