Posterior Wall Ablation Characteristics and Esophageal Safety of an Optimized Protocol for Voltage‐Guided, High‐Power Short‐Duration Ablation of Atrial Fibrillation

Lisa C Costello-Boerrigter iD, Frank Steinborn, Mykhaylo Chapran, Kourosh Vathie, Nemanja Milisavljevic, Mohamad Assani, Ralf Surber, Christina Grieger, Jens Martin Kittner, Anja Schade

Journal of Cardiovascular Electrophysiology · 2025

DOI: 10.1111/jce.16793 ↗

Kurz gefasst

Vergleichsstudie in der Zeitschrift Journal of Cardiovascular Electrophysiology, 2025. Verfasst von Lisa C Costello-Boerrigter und 9 weiteren Autor:innen. Beteiligte Einrichtung: Department of Cardiology, Heart Center, Zentralklinik Bad Berka and Clinical Research, Bad Berka, Germany. Hauptthemen laut MEDLINE: Atrial Fibrillation, Catheter Ablation, Esophagus. Die Arbeit nennt 29 Literaturangaben. Gefördert von: The authors received no specific funding for this work..

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Introduction

The ablation index (AI) standardizes lesions in radiofreqency ablation (RF) of atrial fibrillation (AF). High‐power, short‐duration ablation (HPSD) shortens procedures, but AI is histologically unvalidated in HPSD. We evaluated esophageal safety with voltage‐adapted AF ablation using an optimized, AI‐guided HPSD (AI‐HPSD) protocol.

Methods

Consecutive AF patients undergoing AI‐HPSD at 50 W (AI = 400–450 for posterior left atrium (LA); AI ≥ 500 anteriorly) were compared with a recent AF cohort treated by AI‐guided low‐power, long‐duration ablation (AI‐LPLD). Esophageal endoscopy was performed 1–3 days postablation. Posterior wall lesion characteristics and endoscopically‐detected esophageal lesions (EDEL) were compared.

Results

AI‐LPLD ( n = 100) and AI‐HPSD ( n = 100) groups had similar baselines, except AI‐LPLD had slightly larger LA‐area. VISITAG numbers were comparable, but total posterior wall RF time was shorter with AI‐HPSD versus AI‐LPLD [4.1 (2.1–12.7) vs. 10.9 (5.1–26.6), p < 0.001]. Mean AI and mean impedance drop were higher in AI‐HPSD [449 (394–487) vs. 399 (329–485), p < 0.001 and 8.7 (3.9–15.7) vs. 7.4 (3.6–18.2), p = 0.004]. AI standard deviation was lower with AI‐HPSD [25 (9–79) vs. 48 (19–100), p < 0.001]. Although Max AI values were higher in AI‐HPSD [514 (435–662) vs. 492 (404‐644), p = 0.003), maximum impedance drop did not differ significantly. EDEL rate was comparably low at 2% (AI‐HPSD) and 4% (AI‐LPLD), but AI > 520 occurred more with AI‐HPSD (3.5 ± 5.5% vs. 2.5 ± 5.2%; p = 0.048).

Conclusion

Optimized AI‐HPSD at 50 W with posterior LA target AI = 400–450 was not associated with more EDEL. However, a signal for more unacceptable Max AI values existed. We recommend limiting AI to 400 and developing an automatic, AI‐guided ablation stop.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Atrial FibrillationCatheter AblationEsophagusHumansMaleFemaleMiddle AgedTreatment OutcomeTime FactorsAgedAction PotentialsEsophagoscopyRisk FactorsHeart Rate

Stichwörter der Autor:innen

ablation indexesophageal injuryhigh‐power short‐duration ablationvoltage‐adapted ablation

Autor:innen und Institutionen

  • Department of Cardiology, Heart Center, Zentralklinik Bad Berka and Clinical Research, Bad Berka, Germany.
  • Department of Cardiology/Interventional Electrophysiology, Helios Hospital Erfurt, Universitärer Campus der Health and Medical University, Erfurt, Germany.
  • Department of Internal Medicine 2, Helios Hospital Erfurt, Erfurt, Germany.
  • Department of Internal Medicine 1/Cardiology, Jena University Hospital, Jena, Germany.
  • Clinic for Rhythmology and Interventional Electrophysiology, Rhön Campus Bad Neustadt, Bad Neustadt/Saale, Germany.

ORCID-Profile: Lisa C Costello-Boerrigter

Förderung

  • The authors received no specific funding for this work.

Zitieren

APA

Costello-Boerrigter, L. C., Steinborn, F., Chapran, M., Vathie, K., Milisavljevic, N., Assani, M., Surber, R., Grieger, C., Kittner, J. M., & Schade, A. (2025). Posterior Wall Ablation Characteristics and Esophageal Safety of an Optimized Protocol for Voltage‐Guided, High‐Power Short‐Duration Ablation of Atrial Fibrillation. Journal of Cardiovascular Electrophysiology. https://doi.org/10.1111/jce.16793

Vancouver

Costello-Boerrigter LC, Steinborn F, Chapran M, Vathie K, Milisavljevic N, Assani M, et al. Posterior Wall Ablation Characteristics and Esophageal Safety of an Optimized Protocol for Voltage‐Guided, High‐Power Short‐Duration Ablation of Atrial Fibrillation. Journal of Cardiovascular Electrophysiology. 2025. doi:10.1111/jce.16793

BibTeX
@article{CostelloBoerrigter2025,
  author = {Costello-Boerrigter, Lisa C and Steinborn, Frank and Chapran, Mykhaylo and Vathie, Kourosh and Milisavljevic, Nemanja and Assani, Mohamad and Surber, Ralf and Grieger, Christina and Kittner, Jens Martin and Schade, Anja},
  title = {Posterior Wall Ablation Characteristics and Esophageal Safety of an Optimized Protocol for Voltage‐Guided, High‐Power Short‐Duration Ablation of Atrial Fibrillation},
  journal = {Journal of Cardiovascular Electrophysiology},
  year = {2025},
  doi = {10.1111/jce.16793}
}
Kostenlos starten →