Impact of Recurrence‐to‐Repeat Ablation Time on Long‐Term Efficacy and Safety of Patients With Paroxysmal Atrial Fibrillation: Time Matters

Yuen Hoong Phang iD, Ting-Yung Chang iD, Shih-Lin Chang iD, Yenn-Jiang Lin iD, Li-Wei Lo, Yu-Feng Hu iD, Fa-Po Chung iD, Chin-Yu Lin iD, Ling Kuo, Chih-Min Liu, Shih-Ann Chen iD

Journal of Cardiovascular Electrophysiology · 2025

DOI: 10.1111/jce.16742 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Cardiovascular Electrophysiology, 2025. Verfasst von Yuen Hoong Phang und 10 weiteren Autor:innen. Beteiligte Einrichtung: Department of Medicine, Heart Rhythm Center, Division of Cardiology, Taipei Veterans General Hospital, Taipei, Taiwan. Hauptthemen laut MEDLINE: Atrial Fibrillation, Catheter Ablation, Time-to-Treatment. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 36 Literaturangaben. Gefördert von: This study was supported partially by Ministry of Science and Technology (Grant numbers: 110-2314-B-A49A-542, 111-2314-B-A49-007-MY3, 113-2314-B-075-029-MY3, 1….

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Rhythm control with catheter ablation has been established in the management of atrial fibrillation (AF), but the recurrence of AF remains significant. Several studies have demonstrated the benefits of repeat catheter ablation in patients with recurrent AF. However, the optimal timing for repeat ablation to minimize adverse atrial remodeling following recurrence has not been adequately investigated. In this study, we aimed to determine if an optimal timing for repeat catheter ablation existed in patients with recurrent AF.

Method

We retrospectively screened 1131 patients receiving AF ablation at Taipei Veterans General Hospital and enrolled patients with paroxysmal AF undergoing repeat ablation procedures. Finally, 65 patients were enrolled for further analysis and patients are separated into two groups according to analysis of receiver operating characteristic (ROC) curve of recurrence to repeat ablation time (RAT).

Result

After analysis, the optimal RAT was 222 days, around 7.5 months, with a sensitivity of 56% and a specificity of 78% for 2nd recurrence. KM survival curve also demonstrated Group 2 (RAT ≥ 222) had higher recurrence of atrial arrhythmias after 2nd ablation ( p = 0.01). In multivariable analysis, RAT was shown to be an independent predictor of long‐term outcome in patient with AF.

Conclusion

Our study suggests that early repeat ablation might be advantageous in managing AF, extending arrhythmia‐free intervals, and potentially preventing progression to more persistent arrhythmic forms. Given AF's progressive nature, these results advocate for early intervention strategies aimed at minimizing adverse atrial remodeling and enhancing quality of life for patients.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Atrial FibrillationCatheter AblationTime-to-TreatmentHumansMaleFemaleRecurrenceTime FactorsRetrospective StudiesMiddle AgedAgedRisk FactorsTreatment OutcomeHeart RateAction PotentialsRisk AssessmentTaiwanReoperation

Stichwörter der Autor:innen

ablationatrial fibrillationefficacy and safetyrecurrence‐to‐repeat ablation time

Autor:innen und Institutionen

  • Department of Medicine, Heart Rhythm Center, Division of Cardiology, Taipei Veterans General Hospital, Taipei, Taiwan.
  • Division of Cardiology, Hospital Sultanah Bahiyah, Alor Setar, Malaysia.
  • School of Medicine, National Yang Ming Chiao Tung University, Taipei, Taiwan.
  • Institute of Clinical Medicine and Cardiovascular Research Institute, National Yang-Ming Chiao Tung University, Taipei, Taiwan.
  • National Taipei University of Nursing and Health Sciences, Taipei, Taiwan.
  • Department of Experimental Examination, Healthcare and Services Center, Taipei Veterans General Hospital, Taipei, Taiwan.

ORCID-Profile: Yuen Hoong Phang, Ting-Yung Chang, Shih-Lin Chang, Yenn-Jiang Lin, Yu-Feng Hu, Fa-Po Chung, Chin-Yu Lin, Shih-Ann Chen

Förderung

  • This study was supported partially by Ministry of Science and Technology (Grant numbers: 110-2314-B-A49A-542, 111-2314-B-A49-007-MY3, 113-2314-B-075-029-MY3, 1…

Zitieren

APA

Phang, Y. H., Chang, T. Y., Chang, S. L., Lin, Y. J., Lo, L. W., Hu, Y. F., Chung, F. P., Lin, C. Y., Kuo, L., Liu, C. M., & Chen, S. A. (2025). Impact of Recurrence‐to‐Repeat Ablation Time on Long‐Term Efficacy and Safety of Patients With Paroxysmal Atrial Fibrillation: Time Matters. Journal of Cardiovascular Electrophysiology. https://doi.org/10.1111/jce.16742

Vancouver

Phang YH, Chang TY, Chang SL, Lin YJ, Lo LW, Hu YF, et al. Impact of Recurrence‐to‐Repeat Ablation Time on Long‐Term Efficacy and Safety of Patients With Paroxysmal Atrial Fibrillation: Time Matters. Journal of Cardiovascular Electrophysiology. 2025. doi:10.1111/jce.16742