Visualization of Electrophysiologically Defined Superior Vena Cava‐Right Atrium Junction With High‐Resolution Mapping Using Atrial Extrastimulus
Journal of Cardiovascular Electrophysiology · 2025
DOI: 10.1111/jce.16659 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Cardiovascular Electrophysiology, 2025. Verfasst von Masahiro Ishikura und 3 weiteren Autor:innen. Beteiligte Einrichtung: Department of Cardiology, Gifu Heart Center, Gifu, Japan. Hauptthemen laut MEDLINE: Vena Cava, Superior, Heart Atria, Electrophysiologic Techniques, Cardiac, Action Potentials. Die Arbeit nennt 9 Literaturangaben. Gefördert von: The authors received no specific funding for this work..
Abstract (Originalsprache)
Background
Recent studies have identified diagonal conduction block lines at the electrophysiologically defined superior vena cava (SVC)‐right atrium (RA) junction using three‐dimensional mapping systems and reported the utility of SVCI using these lines. However, these block lines are not always observed, requiring the use of a conventional horizontal isolation approach.
Objective
This study aimed to visualize the electrophysiologically defined SVC‐RA junction using high‐resolution mapping with atrial extrastimulus pacing.
Methods
Twenty‐five patients underwent high‐resolution mapping during sinus rhythm (Sinus map) and extrastimulus pacing (S2 map) using a three‐dimensional mapping system (CARTO 3, version 8). Slow conduction or conduction block along the SVC‐RA junction was assessed by adjusting the lower threshold cut‐off value in the “early meets late” analysis. The length of slow or conduction block lines was compared between the two maps.
Results
The S2 map revealed significantly longer slow or conduction block lines compared to the Sinus map (52.5 ± 18.0 mm vs. 35.6 ± 16.1 mm, p = 0.0013). The adjusted lower threshold values were comparable between the two maps: 26.4 ± 3.7% for the S2 map and 25.2 ± 3.8% for the Sinus map ( p = 0.2819). In the S2 map, a slow or block line covering more than half of the junction was observed in all patients. Furthermore, the sinus node was consistently located inferior to this line.
Conclusion
High‐resolution mapping with atrial extrastimulus pacing more clearly visualizes the SVC‐RA junction, potentially enabling more effective SVCI and estimation of the sinus node location.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Cardiology, Gifu Heart Center, Gifu, Japan.
Förderung
- The authors received no specific funding for this work.
Zitieren
APA
Ishikura, M., Kawase, Y., Miyake, T., & Matsuo, H. (2025). Visualization of Electrophysiologically Defined Superior Vena Cava‐Right Atrium Junction With High‐Resolution Mapping Using Atrial Extrastimulus. Journal of Cardiovascular Electrophysiology. https://doi.org/10.1111/jce.16659
Vancouver
Ishikura M, Kawase Y, Miyake T, Matsuo H. Visualization of Electrophysiologically Defined Superior Vena Cava‐Right Atrium Junction With High‐Resolution Mapping Using Atrial Extrastimulus. Journal of Cardiovascular Electrophysiology. 2025. doi:10.1111/jce.16659
BibTeX
@article{Ishikura2025,
author = {Ishikura, Masahiro and Kawase, Yoshiaki and Miyake, Taiji and Matsuo, Hitoshi},
title = {Visualization of Electrophysiologically Defined Superior Vena Cava‐Right Atrium Junction With High‐Resolution Mapping Using Atrial Extrastimulus},
journal = {Journal of Cardiovascular Electrophysiology},
year = {2025},
doi = {10.1111/jce.16659}
}
EUVIMED