EUVIMEDEUVIMED entdecken
Beobachtungsstudie

Predictors of Right Ventricular Pacing in Patients Undergoing Implantable Defibrillator Placement

James P Hummel, Zhou Lan, Paul W Jones, Rohan Khera, Kenneth Stein, Jeptha P Curtis, Joseph G Akar iD

Journal of Cardiovascular Electrophysiology · 2025

DOI: 10.1111/jce.16570 ↗

Kurz gefasst

Beobachtungsstudie in der Zeitschrift Journal of Cardiovascular Electrophysiology, 2025. Verfasst von James P Hummel und 6 weiteren Autor:innen. Beteiligte Einrichtung: Section of Cardiovascular Medicine, Yale University School of Medicine, New Haven, Connecticut, USA. Hauptthemen laut MEDLINE: Defibrillators, Implantable, Cardiac Pacing, Artificial, Electric Countershock, Ventricular Function, Right. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 25 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Introduction

Identifying patients who will develop a need for right ventricular (RV) pacing after defibrillator (ICD) placement would help inform appropriate device selection, specifically to identify patients who might be more suitable for dual chamber or biventricular transvenous defibrillators versus single‐chamber or subcutaneous devices which do not provide pacing. We sought to determine predictors of RV pacing in patients who did not have a pacing indication at the time of initial ICD implant.

Methods

This observational study assessed single‐chamber ICD recipients implanted from 2006 to 2016 from Boston Scientific's ALTITUDE database and linked to the NCDR® ICD Registry. The study population ( n = 11 044) of ICDs (programmed VVI mode at 40 bpm), and without a clinical indication for pacing. was randomly divided into training and validation cohorts (70/30) and characteristics associated with RV pacing were identified using logistic regression. The outcome was defined as the development of > 20% RV pacing averaged over any continuous 90‐day period within 24 months after the ICD implant.

Results

Patients who developed > 20% RV pacing ( n = 148, 1.3%) had a higher likelihood of being older, male, and with a history of syncope, ventricular tachycardia or cardiac arrest, hypertension, previous or ongoing AF, and longer PR, QRS duration and BUN level ( p < 0.01). After adjustment, PR > 230 ms, history of AF, ongoing AF at time of implant, history of VT or cardiac arrest, and age > 70 were independently associated with RV pacing.

Conclusions

This study provides insight into predictors of RV pacing in ICD recipients without pacing needs at baseline.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Defibrillators, ImplantableCardiac Pacing, ArtificialElectric CountershockVentricular Function, RightArrhythmias, CardiacHumansMaleFemaleAgedMiddle AgedRisk FactorsTime FactorsRegistriesTreatment OutcomeRisk AssessmentDatabases, FactualRetrospective Studies

Stichwörter der Autor:innen

ICDatrial fibrillationright ventricular pacing

Autor:innen und Institutionen

  • Section of Cardiovascular Medicine, Yale University School of Medicine, New Haven, Connecticut, USA.
  • Boston Scientific, St. Paul, Minnesota, USA.

ORCID-Profile: Joseph G Akar

Zitieren

APA

Hummel, J. P., Lan, Z., Jones, P. W., Khera, R., Stein, K., Curtis, J. P., & Akar, J. G. (2025). Predictors of Right Ventricular Pacing in Patients Undergoing Implantable Defibrillator Placement. Journal of Cardiovascular Electrophysiology. https://doi.org/10.1111/jce.16570

Vancouver

Hummel JP, Lan Z, Jones PW, Khera R, Stein K, Curtis JP, et al. Predictors of Right Ventricular Pacing in Patients Undergoing Implantable Defibrillator Placement. Journal of Cardiovascular Electrophysiology. 2025. doi:10.1111/jce.16570

BibTeX
@article{Hummel2025,
  author = {Hummel, James P and Lan, Zhou and Jones, Paul W and Khera, Rohan and Stein, Kenneth and Curtis, Jeptha P and Akar, Joseph G},
  title = {Predictors of Right Ventricular Pacing in Patients Undergoing Implantable Defibrillator Placement},
  journal = {Journal of Cardiovascular Electrophysiology},
  year = {2025},
  doi = {10.1111/jce.16570}
}
Kostenlos starten →