CineECG Repolarization Gradients Predict Acute Hemodynamic Response in CRT Patients
Journal of Cardiovascular Electrophysiology · 2025
DOI: 10.1111/jce.16525 ↗Kurz gefasst
Vergleichsstudie in der Zeitschrift Journal of Cardiovascular Electrophysiology, 2025. Verfasst von Ksenia Sedova und 7 weiteren Autor:innen. Beteiligte Einrichtung: Department of Biomedical Technology, Faculty of Biomedical Engineering, Czech Technical University in Prague, Kladno, Czech Republic. Hauptthemen laut MEDLINE: Cardiac Resynchronization Therapy, Cardiac Resynchronization Therapy Devices, Electrocardiography. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 32 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: This study was supported by the project National Institute for Research of Metabolic and Cardiovascular Diseases (Programme EXCELES, Project No. LX22NPO5104) -….
Abstract (Originalsprache)
Introduction
A variable proportion of non‐responders to cardiac resynchronization therapy (CRT) warrants the search for new approaches to optimize the position of the left ventricular (LV) lead and the CRT device programming. CineECG is a novel ECG modality proposed for the spatial visualization and quantification of myocardial depolarization and repolarization sequences.
Objective
The present study aimed to evaluate CineECG‐derived parameters in different pacing modes and to test their associations with acute hemodynamic responses in CRT patients. Methods and Results CineECG was used to construct the average electrical path within the cardiac anatomy from the 12‐lead ECG. CineECG and LV dP/dt max were tested in 15 patients with nonischemic dilated cardiomyopathy and left bundle branch block (QRS: 170 ± 17 ms; LVEF: 26 ± 5.5%) under pacing protocols with different LV lead localizations. The CineECG‐derived path directions were computed for the QRS and ST‐T intervals for the anteroposterior (X h ), interventricular (Y h ), and apicobasal (Z h ) axes. In a multivariate linear regression analysis with adjustment for the pacing protocol type, the ST‐T path direction Y h was independently associated with the increase in dP/dt max during CRT, [regression coefficient 639.4 (95% confidence interval: 187.9–1090.9), p = 0.006]. In ROC curve analysis, the ST‐T path direction Y h was associated with the achievement of a 10% increase in dP/dt max (AUC: 0.779, p = 0.002) with the optimal cut‐off > 0.084 (left‐to‐right direction) with sensitivity 0.67 and specificity 0.92.
Conclusion
The acute hemodynamic response in CRT patients was associated with specific CineECG repolarization sequence parameters, warranting their further testing as potential predictors of clinical outcomes.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Biomedical Technology, Faculty of Biomedical Engineering, Czech Technical University in Prague, Kladno, Czech Republic.
- Department of Cardiology, Institute for Clinical and Experimental Medicine, Prague, Czech Republic.
- Center for Digital Medicine and Robotics, Jagiellonian University Medical College, Krakow, Poland.
ORCID-Profile: Ksenia Sedova, Jan E Azarov
Förderung
- This study was supported by the project National Institute for Research of Metabolic and Cardiovascular Diseases (Programme EXCELES, Project No. LX22NPO5104) -…
Zitieren
APA
Sedova, K., Azarov, J. E., Van Dam, P. M., Necasova, L., Kukla, J., Sramko, M., Kryze, L., & Kautzner, J. (2025). CineECG Repolarization Gradients Predict Acute Hemodynamic Response in CRT Patients. Journal of Cardiovascular Electrophysiology. https://doi.org/10.1111/jce.16525
Vancouver
Sedova K, Azarov JE, Van Dam PM, Necasova L, Kukla J, Sramko M, et al. CineECG Repolarization Gradients Predict Acute Hemodynamic Response in CRT Patients. Journal of Cardiovascular Electrophysiology. 2025. doi:10.1111/jce.16525
BibTeX
@article{Sedova2025,
author = {Sedova, Ksenia and Azarov, Jan E and Van Dam, Peter M and Necasova, Lucie and Kukla, Jan and Sramko, Marek and Kryze, Lukas and Kautzner, Josef},
title = {CineECG Repolarization Gradients Predict Acute Hemodynamic Response in CRT Patients},
journal = {Journal of Cardiovascular Electrophysiology},
year = {2025},
doi = {10.1111/jce.16525}
}
EUVIMED