EUVIMEDEUVIMED entdecken
Multizentrische Studie

Multielectrode mapping for premature ventricular contraction ablation – A prospective, multicenter study

Pedro A Sousa, Sérgio Barra, Nuno Cortez-Dias, Ziad Khoueiry, José Paulo, Natália António, Afonso Ferreira, Mariana Pereira, Philippe Lagrange, Joao de Sousa, Luís Elvas, Fermin C Garcia und 1 weitere

International Journal of Cardiology · 2023

DOI: 10.1016/j.ijcard.2023.04.044 ↗

Kurz gefasst

Multizentrische Studie in der Zeitschrift International Journal of Cardiology, 2023. Verfasst von Pedro A Sousa und 12 weiteren Autor:innen. Beteiligte Einrichtung: Pacing & Electrophysiology Unit, Cardiology Department, Coimbra's Hospital and University Center, Coimbra, Portugal. Electronic address: peter@chuc.m…. Hauptthemen laut MEDLINE: Ventricular Premature Complexes, Catheter Ablation. Die Arbeit wurde bisher 7-mal zitiert (Crossref) und nennt 19 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

PURPOSE: We aim to evaluate whether the use of a multielectrode mapping catheter could lead to higher efficacy of premature ventricular contraction (PVC) ablation. METHODS: Prospective, multicenter nonrandomized study of consecutive patients referred for PVC ablation from January 2018 to June 2021. Patients were separated into two groups: activation map performed with the PentaRay catheter (Study group) or with the ablation catheter (Control group). PMF software was used in both groups. Procedural endpoints and 1-year freedom from ventricular arrhythmia were assessed. RESULTS: During the enrollment period 136 patients (60% males, mean age of 55 ± 17 years, 60% left-sided origin) fulfilled the inclusion criteria - 68 patients in each group. Patients in the Study Group had a sevenfold higher number of acquired activation points (768 ± 728 vs. 110 ± 79, p < 0.01), a shorter mapping time (28 ± 19 min vs. 49 ± 32 min, p < 0.01) and a quicker procedure time (110 ± 33 min vs. 134 ± 50 min, p < 0.01), compared to patients in the Control Group. While there were no significant differences in the acute success (95.6% in the Study Group vs. 90.1% in Control group, p = 0.49), or adverse events (4% in the Study group vs. 7% in the Control group, p = 0.72), patients in the Study group had a higher freedom from ventricular arrhythmia at 1-year (89.7% vs. 70.6%, p = 0.01). The use of the PentaRay catheter was an independent predictor of success (HR = 6.20 [95% CI, 1.08-35.47], p = 0.003). CONCLUSIONS: The use of the PentaRay catheter may improve the outcome of PVC ablation while reducing procedure time.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Ventricular Premature ComplexesCatheter AblationMaleHumansAdultMiddle AgedAgedFemaleProspective StudiesCathetersSoftwareTime FactorsTreatment Outcome

Stichwörter der Autor:innen

Catheter ablationPattern matching filter softwarePentaRay catheterPremature ventricular contraction

Autor:innen und Institutionen

  • Pacing & Electrophysiology Unit, Cardiology Department, Coimbra's Hospital and University Center, Coimbra, Portugal. Electronic address: peter@chuc.min-saude.pt.
  • Cardiology Department, Hospital da Luz Arrábida, V. N. Gaia, Portugal.
  • Arrhythmia Unit, Cardiology Department, Santa Maria University Hospital, Lisbon Academic Medical Center, Lisbon, Portugal.
  • Cardiology Department, Clinique Saint Pierre, Perpignan, France.
  • Pacing & Electrophysiology Unit, Cardiology Department, Coimbra's Hospital and University Center, Coimbra, Portugal.
  • Pacing & Electrophysiology Unit, Cardiology Department, Coimbra's Hospital and University Center, Coimbra, Portugal; ICBR, Faculty of Medicine, University of Coimbra, Coimbra, Portugal.

Zitieren

APA

Sousa, P. A., Barra, S., Cortez-Dias, N., Khoueiry, Z., Paulo, J., António, N., Ferreira, A., Pereira, M., Lagrange, P., de Sousa, J., Elvas, L., Garcia, F. C., & Gonçalves, L. (2023). Multielectrode mapping for premature ventricular contraction ablation – A prospective, multicenter study. International Journal of Cardiology. https://doi.org/10.1016/j.ijcard.2023.04.044

Vancouver

Sousa PA, Barra S, Cortez-Dias N, Khoueiry Z, Paulo J, António N, et al. Multielectrode mapping for premature ventricular contraction ablation – A prospective, multicenter study. International Journal of Cardiology. 2023. doi:10.1016/j.ijcard.2023.04.044

BibTeX
@article{Sousa2023,
  author = {Sousa, Pedro A and Barra, Sérgio and Cortez-Dias, Nuno and Khoueiry, Ziad and Paulo, José and António, Natália and Ferreira, Afonso and Pereira, Mariana and Lagrange, Philippe and de Sousa, Joao and Elvas, Luís and Garcia, Fermin C and Gonçalves, Lino},
  title = {Multielectrode mapping for premature ventricular contraction ablation – A prospective, multicenter study},
  journal = {International Journal of Cardiology},
  year = {2023},
  doi = {10.1016/j.ijcard.2023.04.044}
}
Kostenlos starten →