EUVIMEDObjevte EUVIMED
VergleichsstudieZurückgezogene Publikation

RETRACTED: A comparison of procedure‐related adverse events between two right ventricular leadless pacemakers

Ali Bahbah iD, Jay Sengupta, Melanie Kapphahn-Bergs, Dawn Witt, Edwin Zishiri, Scott Sharkey, Dimitrios Strepkos, Michaella Alexandrou, Raed Abdelhadi, Robert Hauser iD

Journal of Cardiovascular Electrophysiology · 2024-12 · 35 (12) · 2397-2401

DOI: 10.1111/jce.16458 ↗

At a glance

Vergleichsstudie in Journal of Cardiovascular Electrophysiology, published online on 2024-10-13. Written by Ali Bahbah and 9 co-authors. Institution: The Joseph F. Novogratz Family Heart Rhythm Science Center, Minneapolis Heart Institute Foundation, Minneapolis, Minnesota, USA. Major MEDLINE topics: Pacemaker, Artificial, Equipment Design, Databases, Factual, Cardiac Pacing, Artificial. Cited 6 times so far (Crossref); 14 references.

AbstraktSubjectsBibliografické údajeCiteRelated studies

Abstract (original language)

Introduction

The Medtronic Micra VR and Abbott AVEIR VR are the leadless pacemakers (LPM) currently available in the United States (US). Micra VR employs fixation tines and the AVEIR VR uses an active fixation helix. Micra VR requires fixation before electrical measurements are obtained, while R‐waves may be mapped by AVEIR VR without fixation. Little comparative data is available for these LPMs. Accordingly, we compared the incidences of procedure‐related major adverse clinical events (MACE) and device problems in the US for Micra VR and AVEIR VR during 2022–2024.

Methods

We searched the FDA's Manufacturer and User Facility Device Experience (MAUDE) database for US reports of MACE and device problems that were filed from April 2022 to December 2023 for AVEIR VR, and from June 2022 to April 2024 for Micra VR. Totals for US‐registered LPM implants were obtained from the manufacturers' product performance reports.

Results

During the study period, 5990 AVEIR VR and 10 940 Micra VR implants were registered in the US. We found 305 MAUDE reports for AVEIR VR (5.1%), versus 541 MAUDE reports for Micra VR (4.9%) ( p = .702). The incidence of MACE was 0.72% (43/5990) for AVEIR VR versus 0.59% (65/10 940) for Micra VR, ( p = .387). The incidences of procedure‐related death, cardiac perforation. cardiac arrest, emergency pericardial drainage or reparative surgery were similar for both LPMs ( p > .05). Micra VR had more unacceptable thresholds requiring LPM replacement compared to AVEIR VR (95;0.9% vs. 24;0.4%; p = .001). AVEIR VR had a statistically higher incidence of device dislodgement during (32) and after (21) implant compared to Micra VR (53 (0.9%) vs. 46 (0.4%), p < .001).

Conclusions

Micra VR and AVEIR VR have similar procedural safety profiles, including the incidences of death and perforation. However, device problems differed significantly, possibly related to their design differences. Compared to Micra VR, AVEIR VR appears to have an advantageous threshold measurement capability but is more prone to device dislodgement.

Subjects

MeSH terms (MEDLINE)

Pacemaker, ArtificialEquipment DesignDatabases, FactualCardiac Pacing, ArtificialHumansUnited StatesRisk FactorsTreatment OutcomeTime FactorsEquipment FailureVentricular Function, RightArrhythmias, CardiacAction PotentialsRisk AssessmentHeart Rate

Author keywords

cardiac devicescardiac pacingdevice problemsleadlesspacemakersperforationprocedural complicationstamponadetranscatheter

Authors and institutions

  • The Joseph F. Novogratz Family Heart Rhythm Science Center, Minneapolis Heart Institute Foundation, Minneapolis, Minnesota, USA.
  • Minneapolis Heart Institute Foundation, Minneapolis, Minnesota, USA.
  • Minneapolis Heart Institute, Minneapolis, Minnesota, USA.

ORCID profiles: Ali Bahbah, Robert Hauser

Cite

APA

Bahbah, A., Sengupta, J., Kapphahn-Bergs, M., Witt, D., Zishiri, E., Sharkey, S., Strepkos, D., Alexandrou, M., Abdelhadi, R., & Hauser, R. (2024). RETRACTED: A comparison of procedure‐related adverse events between two right ventricular leadless pacemakers. Journal of Cardiovascular Electrophysiology, 35(12), 2397-2401. https://doi.org/10.1111/jce.16458

Vancouver

Bahbah A, Sengupta J, Kapphahn-Bergs M, Witt D, Zishiri E, Sharkey S, et al. RETRACTED: A comparison of procedure‐related adverse events between two right ventricular leadless pacemakers. Journal of Cardiovascular Electrophysiology. 2024;35(12):2397-2401. doi:10.1111/jce.16458

BibTeX
@article{Bahbah2024,
  author = {Bahbah, Ali and Sengupta, Jay and Kapphahn-Bergs, Melanie and Witt, Dawn and Zishiri, Edwin and Sharkey, Scott and Strepkos, Dimitrios and Alexandrou, Michaella and Abdelhadi, Raed and Hauser, Robert},
  title = {RETRACTED: A comparison of procedure‐related adverse events between two right ventricular leadless pacemakers},
  journal = {Journal of Cardiovascular Electrophysiology},
  year = {2024},
  volume = {35},
  number = {12},
  pages = {2397--2401},
  doi = {10.1111/jce.16458}
}
Start for free →