Familial risk of sinus node dysfunction indicating pacemaker implantation: a nationwide cohort study
Europace · 2024
DOI: 10.1093/europace/euae287 ↗Kurz gefasst
Kohortenstudie in der Zeitschrift Europace, 2024. Verfasst von Morten Krogh Christiansen und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Cardiology, Viborg Regional Hospital, Heibergs alle 2K, DK-8800 Viborg, Denmark. Hauptthemen laut MEDLINE: Sick Sinus Syndrome, Registries, Pacemaker, Artificial. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 36 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Skibsreder Per Henriksen, R og hustrus fond.
Abstract (Originalsprache)
Aims
We aimed to investigate the risk of sinus node dysfunction (SND) indicating cardiac pacing and mortality in first-degree relatives to patients with a pacemaker implanted on this indication and assess the effect of onset-age on disease risk. Methods and results In this nationwide register-based study, we used the Danish Civil Registration Registry to establish family structures and merged data with the Danish National Patient Registry and the Danish Pacemaker and ICD Registry containing information on all pacemakers implanted due to SND in Denmark. We followed 6 027 090 individuals born after 1954 in the period between 1982 and 2022 (180 775 041 person-years) among whom 2.477 pacemakers were implanted due to SND. The adjusted rate ratio (RR) of pacemaker-treated SND was 2.9 (2.4–3.6) for individuals having any father, mother, or sibling with a pacemaker implanted on this indication compared with the general population (derived cumulative incidence at the age of 68 years: 0.79 and 0.27%, respectively). This risk was inversely proportional to implantation age in the index person [≤60 years: RR = 5.5 (3.4–9.0)]. Overall, mortality was similar between individuals having a father, mother, or sibling with SND and the general population, but higher for relatives to index persons with an early onset [≤60 years: RR = 1.22 (1.05–1.41)].
Conclusion
First-degree relatives to SND patients are at increased risk of SND with risk being inversely associated with pacemaker implantation age in the index person. Mortality in first-degree relatives was comparable with the general population, although subgroup findings suggest an increased mortality among individuals with a family history of early-onset SND.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Cardiology, Viborg Regional Hospital, Heibergs alle 2K, DK-8800 Viborg, Denmark.
- Department of Clinical Medicine, Health, Aarhus University, Palle Juul-Jensens Boulevard 99, DK-8200 Aarhus N, Denmark.
- Department of Public Health, Section of Biostatistics, Aarhus University, Aarhus, Denmark.
- Department of Cardiology, Odense University Hospital, Odense, Denmark.
- Department of Cardiology, Aarhus University Hospital, Aarhus, Denmark.
ORCID-Profile: Morten Krogh Christiansen, Erik Thorlund Parner, Jens Brock Johansen, Jens Cosedis Nielsen, Henrik Kjærulf Jensen
Förderung
- Skibsreder Per Henriksen, R og hustrus fond
Zitieren
APA
Christiansen, M. K., Parner, E. T., Johansen, J. B., Nielsen, J. C., & Jensen, H. K. (2024). Familial risk of sinus node dysfunction indicating pacemaker implantation: a nationwide cohort study. Europace. https://doi.org/10.1093/europace/euae287
Vancouver
Christiansen MK, Parner ET, Johansen JB, Nielsen JC, Jensen HK. Familial risk of sinus node dysfunction indicating pacemaker implantation: a nationwide cohort study. Europace. 2024. doi:10.1093/europace/euae287
BibTeX
@article{Christiansen2024,
author = {Christiansen, Morten Krogh and Parner, Erik Thorlund and Johansen, Jens Brock and Nielsen, Jens Cosedis and Jensen, Henrik Kjærulf},
title = {Familial risk of sinus node dysfunction indicating pacemaker implantation: a nationwide cohort study},
journal = {Europace},
year = {2024},
doi = {10.1093/europace/euae287}
}