Incidence and economics of transvenous ICD lead complications: Implications for tricuspid valve function and interventions
Journal of Cardiovascular Electrophysiology · 2024
DOI: 10.1111/jce.16385 ↗At a glance
Journal article in Journal of Cardiovascular Electrophysiology, 2024. Written by Pamela K Mason and 5 co-authors. Institution: Department of Medicine, University of Virginia, Charlottesville, Virginia, USA. Major MEDLINE topics: Defibrillators, Implantable, Tricuspid Valve, Medicare, Device Removal. Cited 2 times so far (Crossref); 4 references. The full text is freely available (open access, CC BY 4.0). Funded by: Medtronic.
Abstract (original language)
Background
Implantable cardioverter‐defibrillators are used globally and are reliable, but complications related to transvenous leads remain a concern. Evidence related to the incidence and costs of those complications is heterogeneous with respect to scope and healthcare system. This analysis aims to create estimates of the incidence and costs of tricuspid valve (TV) complications, lead failures, and lead extractions from a single large real‐world data set. Methods and Results This retrospective longitudinal cohort study used the deidentified Medicare Fee for Service administrative claims database. A total of 116 036 patients with de novo transvenous ICD implant were analyzed. Mean hospital costs were $26 903 for tricuspid valve complications, $20 851 for lead failures, and $22 278 for lead extractions.
Conclusions
Transvenous ICD lead complications incur significant costs to patients, hospitals, and payers when they occur. Advancements in lead technology that reduce these complications could bring significant clinical and economic value.
Subjects
MeSH terms (MEDLINE)
Author keywords
Authors and institutions
- Department of Medicine, University of Virginia, Charlottesville, Virginia, USA.
- Lindner Research Center, The Christ Hospital, Cincinnati, Ohio, USA.
- Medtronic, Inc., Mounds View, Minnesota, USA.
- Heart and Vascular Institute, Vanderbilt University, Nashville, Tennessee, USA.
ORCID profiles: George H Crossley
Funding
- Medtronic
Cite
APA
Mason, P. K., Schloss, E. J., Holbrook, R., Chiddarwar, T., Zhou, J., & Crossley, G. H. (2024). Incidence and economics of transvenous ICD lead complications: Implications for tricuspid valve function and interventions. Journal of Cardiovascular Electrophysiology. https://doi.org/10.1111/jce.16385
Vancouver
Mason PK, Schloss EJ, Holbrook R, Chiddarwar T, Zhou J, Crossley GH. Incidence and economics of transvenous ICD lead complications: Implications for tricuspid valve function and interventions. Journal of Cardiovascular Electrophysiology. 2024. doi:10.1111/jce.16385
BibTeX
@article{Mason2024,
author = {Mason, Pamela K and Schloss, Edward J and Holbrook, Reece and Chiddarwar, Tanvi and Zhou, Jiani and Crossley, George H},
title = {Incidence and economics of transvenous ICD lead complications: Implications for tricuspid valve function and interventions},
journal = {Journal of Cardiovascular Electrophysiology},
year = {2024},
doi = {10.1111/jce.16385}
}
EUVIMED