EUVIMEDOpdag EUVIMED
VergleichsstudieOpen access · CC BY 4.0

Association between high‐density mapping of atypical atrial flutter, clinical outcomes and healthcare utilization

Joshua Sink, Kasen Culler, Lakshmi Uppalapati, Nicola Lancki, Graham Peigh, Graham Lohrmann, Mahmoud Elsayed, Herman Carneiro, Jayson Baman, Anna Pfenniger, Kaustubha D Patil iD, Nishant Verma iD and 6 more

Journal of Cardiovascular Electrophysiology · 2024

DOI: 10.1111/jce.16355 ↗

At a glance

Vergleichsstudie in Journal of Cardiovascular Electrophysiology, 2024. Written by Joshua Sink and 17 co-authors. Institution: Department of Internal Medicine, Northwestern University, Chicago, Illinois, USA. Major MEDLINE topics: Atrial Flutter, Catheter Ablation, Predictive Value of Tests, Electrophysiologic Techniques, Cardiac. Cited 2 times so far (Crossref); 13 references. The full text is freely available (open access, CC BY 4.0). Funded by: NHLBI NIH HHS.

AbstractSubjectsBibliografiske oplysningerCiteRelated studies

Abstract (original language)

Background

Success of atypical atrial flutter (AAFL) ablation has historically been limited by difficulty mapping the complex re‐entrant circuits involved. While high‐density (HD) mapping has become commonplace in clinical practice, there are limited data on outcomes of HD versus non‐HD mapping for AAFL ablation.

Objective

To compare clinical outcomes and healthcare utilization using HD mapping versus non‐HD mapping for AAFL ablation.

Methods

Retrospective analysis of all AAFL procedures between 2005 and 2022 at an academic medical center was conducted. Procedures utilizing a 16‐electrode HD Grid catheter and Precision mapping system were compared to procedures using prior generation 10–20 electrode spiral catheters and the Velocity system (Abbott, IL). Cox regression models and Poisson regression models were utilized to examine procedural and healthcare utilization outcomes. Models were adjusted for left ventricular ejection fraction, CHA 2 DS 2 ‐VASc, and history of prior ablation.

Results

There were 108 patients (62% HD mapping) included in the analysis. Baseline clinical characteristics were similar between groups. Use of HD mapping was associated with a higher rate of AAFL circuit delineation (92.5% vs. 76%; p = .014) and a greater adjusted procedure success rate, defined as non‐inducibility at procedure end, (aRR (95% CI) 1.26 (1.02–1.55) p = .035) than non‐HD mapping. HD mapping was also associated with a lower rate of ED visits (aIRR (95% CI) 0.32 (0.14–0.71); p = .007) and hospitalizations (aIRR (95% CI) 0.32 (0.14–0.68); p = .004) for AF/AFL/HF through 1 year. While there was a lower rate of recurrent AFL through 1 year among HD mapping cases (aHR (95% CI) 0.60 (0.31–1.16) p = .13), statistical significance was not met likely due to the low sample size and higher rate of ambulatory rhythm monitoring in the HD group (61% vs. 39%, p = .025).

Conclusion

Compared to non‐HD mapping, AAFL ablation with HD mapping is associated with improvements in the ability to define the AAFL circuit, greater procedural success, and a reduction in the number of ED visits and hospitalization for AF/AFL/HF.

Subjects

MeSH terms (MEDLINE)

Atrial FlutterCatheter AblationPredictive Value of TestsElectrophysiologic Techniques, CardiacAction PotentialsHumansMaleFemaleRetrospective StudiesMiddle AgedAgedTreatment OutcomeTime FactorsRisk FactorsHeart RatePatient Acceptance of Health CareRecurrenceCardiac Catheters

Author keywords

atypical atrial flutterhealthcare utilizationhigh density mapping

Authors and institutions

  • Department of Internal Medicine, Northwestern University, Chicago, Illinois, USA.
  • Department of Internal Medicine, Baylor University, Houston, Texas, USA.
  • Department of Preventative Medicine, Northwestern University, Chicago, Illinois, USA.
  • Division of Cardiology, Northwestern University, Chicago, Illinois, USA.

ORCID profiles: Kaustubha D Patil, Nishant Verma, Rishi Arora, Alexandru B Chicos, Albert C Lin, Rod S Passman

Funding

  • NHLBI NIH HHS

Cite

APA

Sink, J., Culler, K., Uppalapati, L., Lancki, N., Peigh, G., Lohrmann, G., Elsayed, M., Carneiro, H., Baman, J., Pfenniger, A., Patil, K. D., Verma, N., Arora, R., Kim, S. S., Chicos, A. B., Lin, A. C., Knight, B. P., & Passman, R. S. (2024). Association between high‐density mapping of atypical atrial flutter, clinical outcomes and healthcare utilization. Journal of Cardiovascular Electrophysiology. https://doi.org/10.1111/jce.16355

Vancouver

Sink J, Culler K, Uppalapati L, Lancki N, Peigh G, Lohrmann G, et al. Association between high‐density mapping of atypical atrial flutter, clinical outcomes and healthcare utilization. Journal of Cardiovascular Electrophysiology. 2024. doi:10.1111/jce.16355

BibTeX
@article{Sink2024,
  author = {Sink, Joshua and Culler, Kasen and Uppalapati, Lakshmi and Lancki, Nicola and Peigh, Graham and Lohrmann, Graham and Elsayed, Mahmoud and Carneiro, Herman and Baman, Jayson and Pfenniger, Anna and Patil, Kaustubha D and Verma, Nishant and Arora, Rishi and Kim, Susan S and Chicos, Alexandru B and Lin, Albert C and Knight, Bradley P and Passman, Rod S},
  title = {Association between high‐density mapping of atypical atrial flutter, clinical outcomes and healthcare utilization},
  journal = {Journal of Cardiovascular Electrophysiology},
  year = {2024},
  doi = {10.1111/jce.16355}
}
Start for free →