EUVIMEDEUVIMED entdecken
FallberichtOpen Access · CC BY 4.0

Pacemaker‐mediated reentrant arrhythmia facilitated by an atrial‐tracking leadless pacemaker

Dejan Vrtikapa, Luke Chong, Daniel Modaff, Ryan Kipp iD

Journal of Cardiovascular Electrophysiology · 2024

DOI: 10.1111/jce.16350 ↗

Kurz gefasst

Fallbericht in der Zeitschrift Journal of Cardiovascular Electrophysiology, 2024. Verfasst von Dejan Vrtikapa und 3 weiteren Autor:innen. Beteiligte Einrichtung: Department of Medicine, Division of Cardiology, University of Wisconsin School of Medicine and Public Health, Madison, Wisconsin, USA. Hauptthemen laut MEDLINE: Pacemaker, Artificial, Heart Rate, Action Potentials. Die Arbeit nennt 1 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Introduction

Pacemaker‐mediated tachycardia is a known arrhythmia in patients with dual chamber pacemakers and defibrillators and intact ventriculoatrial (VA) conduction. We report a case of pacemaker‐mediated reentrant arrhythmia (PMRA) in a patient with an atrioventricular (AV) synchronous leadless pacemaker. Methods and Results A 91‐year‐old female presented with 2:1 AV conduction and received an AV synchronous leadless pacemaker. She had atrial mechanical sense‐ventricular paced beats between heart rates of 80–100 bpm more than 80% of the time. She was found to have a new cardiomyopathy and was referred for placement of biventricular pacemaker. At the time of device implantation, her electrocardiogram showed ventricular pacing with a short RP interval and superiorly directed P waves. Changes in the ventricular pacing rate resulted in changes in the atrial rate. Following device placement, her heart rate decreased to the lower rate limit of her pacemaker. The atrial mechanical sense impulse most likely was generated by a retrograde conducted P wave resulting in near incessant PMRA.

Conclusion

PMRA may occur in patients who receive an AV synchronous leadless pacemaker with intact VA conduction and sinoatrial node dysfunction. Due to the lower rates of PMRA, this arrhythmia may be underrecognized. Interventions for and implications of PMRA need further investigation.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Pacemaker, ArtificialHeart RateAction PotentialsHumansFemaleAged, 80 and overCardiac Pacing, ArtificialTreatment OutcomeEquipment DesignElectrocardiographyTachycardia, Atrioventricular Nodal Reentry

Stichwörter der Autor:innen

AV synchronous leadless pacemakercomplete heart blockleadless pacemakerpacemaker arrhythmiapacemaker malfunction

Autor:innen und Institutionen

  • Department of Medicine, Division of Cardiology, University of Wisconsin School of Medicine and Public Health, Madison, Wisconsin, USA.
  • Aurora BayCare Medical Center, Green Bay, Wisconsin, USA.

ORCID-Profile: Ryan Kipp

Zitieren

APA

Vrtikapa, D., Chong, L., Modaff, D., & Kipp, R. (2024). Pacemaker‐mediated reentrant arrhythmia facilitated by an atrial‐tracking leadless pacemaker. Journal of Cardiovascular Electrophysiology. https://doi.org/10.1111/jce.16350

Vancouver

Vrtikapa D, Chong L, Modaff D, Kipp R. Pacemaker‐mediated reentrant arrhythmia facilitated by an atrial‐tracking leadless pacemaker. Journal of Cardiovascular Electrophysiology. 2024. doi:10.1111/jce.16350

BibTeX
@article{Vrtikapa2024,
  author = {Vrtikapa, Dejan and Chong, Luke and Modaff, Daniel and Kipp, Ryan},
  title = {Pacemaker‐mediated reentrant arrhythmia facilitated by an atrial‐tracking leadless pacemaker},
  journal = {Journal of Cardiovascular Electrophysiology},
  year = {2024},
  doi = {10.1111/jce.16350}
}
Kostenlos starten →