EUVIMEDEUVIMED entdecken
Multizentrische StudieKlinische StudieOpen Access · CC BY 4.0

Re-Ablation of Atrial Fibrillation Targeting Electrogram Dispersion in Patients with Isolated Veins: The RESTART Trial

John D Hummel, Paul C Zei, Mark Metzl, Isabel Deisenhofer, Haroon Rashid, Gustavo Morales, Jérôme Horvilleur, Stavros Mountantonakis, Jean-Paul Albenque, Smit Vasaiwala, Tom De Potter, Adi Lador und 17 weitere

Heart Rhythm · 2026

DOI: 10.1016/j.hrthm.2026.01.042 ↗

Kurz gefasst

Multizentrische Studie in der Zeitschrift Heart Rhythm, 2026. Verfasst von John D Hummel und 28 weiteren Autor:innen. Beteiligte Einrichtung: The Ohio State University Wexner Medical Center, Columbus, Ohio. Electronic address: john.Hummel@osumc.edu. Hauptthemen laut MEDLINE: Atrial Fibrillation, Catheter Ablation, Pulmonary Veins, Heart Conduction System. Die Arbeit nennt 32 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Johnson and Johnson, Boston Scientific Corporation.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

BACKGROUND: Pulmonary vein (PV) isolation is a well-established treatment for atrial fibrillation (AF), however, strategies for patients with recurrent AF and isolated PVs remain elusive. OBJECTIVE: This study aimed to evaluate the effectiveness of a personalized artificial intelligence (AI)-guided spatiotemporal dispersion mapping and ablation in patients undergoing a repeat ablation and whose PVs remain isolated from previous ablation procedures. METHODS: The Re-Ablation Using a Tailored Approach Targeting EGM-Dispersion (RESTART) trial (NCT05477147) was an interventional, prospective, single-arm, multicenter clinical trial. Patients with previous catheter or surgical ablation for paroxysmal, persistent, or long-standing persistent AF and with documented symptomatic AF recurrences were enrolled. Patients with documented reconnected PVs during the procedure were prospectively withdrawn from the trial. Follow-up included 3-, 6-, and 12-month visits with 12-lead electrocardiogram and 24-hour Holter. The primary endpoint of the study was freedom from documented AF at 12 months after a single AI-guided repeat ablation procedure. RESULTS: Of the 213 patients enrolled, the main causes for premature study exit were PV reconnection (n = 80) or noninducibility of AF (n = 14). The primary endpoint was achieved in 83% of patients (77 of 93), and freedom from any atrial arrhythmia after a single procedure was 70% (65 of 93). Notably, AF termination during ablation was achieved in 54% of patients, and right atrial dispersion was identified in 59%. The procedure was associated with improvements in quality-of-life metrics (AF Effect on Quality-of-Life questionnaire and 36-Item Short Form Survey scores). CONCLUSION: In patients with documented isolated PVs, AI-guided dispersion ablation is safe and effective and represents an alternative to other ablative strategies.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Atrial FibrillationCatheter AblationPulmonary VeinsHeart Conduction SystemArtificial IntelligenceSurgery, Computer-AssistedElectrophysiologic Techniques, CardiacHumansFemaleMaleProspective StudiesTreatment OutcomeMiddle AgedRecurrenceFollow-Up StudiesElectrocardiography, AmbulatoryReoperation

Stichwörter der Autor:innen

Artificial intelligence–guided ablationAtrial fibrillationDispersionPulmonary vein isolationRedo ablationSpatiotemporal dispersion

Autor:innen und Institutionen

  • The Ohio State University Wexner Medical Center, Columbus, Ohio. Electronic address: john.Hummel@osumc.edu.
  • Mass General Brigham, Harvard Medical School, Boston, Massachusetts.
  • Endeavor Health, Glenview, Illinois.
  • Department of Electrophysiology, Technical University of Munich (TUM), German Heart Center Munich, Munich, Germany.
  • Inova Heart and Vascular Institute and Virginia Heart, Fairfax, Virginia.
  • Arrhythmia Institute at Grandview Medical Center, Birmingham, Alabama.

Förderung

  • Johnson and Johnson
  • Boston Scientific Corporation

Zitieren

APA

Hummel, J. D., Zei, P. C., Metzl, M., Deisenhofer, I., Rashid, H., Morales, G., Horvilleur, J., Mountantonakis, S., Albenque, J. P., Vasaiwala, S., De Potter, T., Lador, A., Magnano, A., Chicos, A. B., Silverstein, J., Guerrero, D., Beguin, S., El-Benna, A., Nguyen-Tu, M. S., …, & Lakkireddy, D. (2026). Re-Ablation of Atrial Fibrillation Targeting Electrogram Dispersion in Patients with Isolated Veins: The RESTART Trial. Heart Rhythm. https://doi.org/10.1016/j.hrthm.2026.01.042

Vancouver

Hummel JD, Zei PC, Metzl M, Deisenhofer I, Rashid H, Morales G, et al. Re-Ablation of Atrial Fibrillation Targeting Electrogram Dispersion in Patients with Isolated Veins: The RESTART Trial. Heart Rhythm. 2026. doi:10.1016/j.hrthm.2026.01.042

BibTeX
@article{Hummel2026,
  author = {Hummel, John D and Zei, Paul C and Metzl, Mark and Deisenhofer, Isabel and Rashid, Haroon and Morales, Gustavo and Horvilleur, Jérôme and Mountantonakis, Stavros and Albenque, Jean-Paul and Vasaiwala, Smit and De Potter, Tom and Lador, Adi and Magnano, Anthony and Chicos, Alexandru B and Silverstein, Joshua and Guerrero, Daniel and Beguin, Shirley and El-Benna, Anas and Nguyen-Tu, Marie-Sophie and Lotteau, Sabine and Milpied, Paola and Durdez, Théophile Mohr and Kalifa, Jérôme and Bars, Clément and Seitz, Julien and D'Souza, Benjamin and Cooper, Daniel H and Nair, Devi and Lakkireddy, Dhanunjaya},
  title = {Re-Ablation of Atrial Fibrillation Targeting Electrogram Dispersion in Patients with Isolated Veins: The RESTART Trial},
  journal = {Heart Rhythm},
  year = {2026},
  doi = {10.1016/j.hrthm.2026.01.042}
}
Kostenlos starten →