EUVIMEDOpdag EUVIMED
VergleichsstudieOpen access · CC BY 4.0

Step‐by‐step recommendations utilizing four‐dimensional intracardiac echocardiography in left atrial appendage procedures

Brett Gidney, Domenico G Della Rocca, Rodney Horton, Joel Hoffman, Miguel Valderrábano iD, Andrea Natale, Jalaj Garg iD, Rahul Bhardwaj iD, Shephal Doshi

Journal of Cardiovascular Electrophysiology · 2024

DOI: 10.1111/jce.16309 ↗

At a glance

Vergleichsstudie in Journal of Cardiovascular Electrophysiology, 2024. Written by Brett Gidney and 8 co-authors. Institution: University of California, Los Angeles (UCLA) Health, Santa Barbara, California, USA. Major MEDLINE topics: Atrial Appendage, Echocardiography, Four-Dimensional, Echocardiography, Transesophageal, Workflow. Cited 6 times so far (Crossref); 19 references. The full text is freely available (open access, CC BY 4.0). Funded by: Biosense Webster, Inc..

AbstractSubjectsBibliografiske oplysningerCiteRelated studies

Abstract (original language)

Introduction

Four‐dimensional (4D) intracardiac echocardiography (ICE) is a novel cardiac imaging modality that has been applied to various workflows, including catheter ablation, tricuspid valve repair, and left atrial appendage occlusion (LAAO). The use of this type of advanced ICE imaging may ultimately allow for the replacement of transesophageal echocardiography (TEE) for LAAO, providing comparable imaging quality while eliminating the need for general anesthesia.

Methods

Based on our initial clinical experience with 4D ICE in LAAO, we have developed an optimized workflow for the use of the NUVISION™ 4D ICE Catheter in conjunction with the GE E95 and S70N Ultrasound Systems in LAAO. In this manuscript, we provide a step‐by‐step guide to using 4D ICE in conjunction with compatible imaging consoles. We have also evaluated the performance of 4D ICE with the NUVISION Ultrasound Catheter versus TEE in one LAAO case and present those results here.

Results

In our comparison of 4D ICE using our optimized workflow with TEE in an LAAO case, ICE LAA measurements were similar to those from TEE. The best image resolution was seen via ICE in 2‐dimensional and multislice modes (triplane and biplane). The FlexiSlice multiplanar reconstruction tool, which creates an en‐face image derived from a 4D volume set, also provided valuable information but yielded slightly lower image quality, as expected for these volume‐derived images. For this case, comparable images were obtained with TEE and ICE but with less need to reposition the ICE catheter.

Conclusion

The use of optimized 4D ICE catheter workflow recommendations allows for efficient LAAO procedures, with higher resolution imaging, comparable to TEE.

Subjects

MeSH terms (MEDLINE)

Atrial AppendageEchocardiography, Four-DimensionalEchocardiography, TransesophagealWorkflowHumansAtrial FibrillationCardiac CatheterizationPredictive Value of TestsUltrasonography, Interventional

Author keywords

cathetercatheter ablationleft atrial appendage occlusiontransesophageal echocardiographytricuspid valveworkflow

Authors and institutions

  • University of California, Los Angeles (UCLA) Health, Santa Barbara, California, USA.
  • Texas Cardiac Arrhythmia Institute, St. David's Medical Center, Austin, Texas, USA.
  • Heart Rhythm Management Centre, Postgraduate Program in Cardiac Electrophysiology and Pacing, Universitair Ziekenhuis Brussel-Vrije Universiteit Brussel, European Reference Networks Guard-Heart, Brussels, Belgium.
  • Biosense Webster, Inc., Irvine, California, USA.
  • Department of Cardiology, Houston Methodist Hospital, Houston, Texas, USA.
  • Department of Cardiology, MetroHealth Medical Center, Case Western Reserve University School of Medicine, Cleveland, Ohio, USA.

ORCID profiles: Miguel Valderrábano, Jalaj Garg, Rahul Bhardwaj

Funding

  • Biosense Webster, Inc.

Cite

APA

Gidney, B., Della Rocca, D. G., Horton, R., Hoffman, J., Valderrábano, M., Natale, A., Garg, J., Bhardwaj, R., & Doshi, S. (2024). Step‐by‐step recommendations utilizing four‐dimensional intracardiac echocardiography in left atrial appendage procedures. Journal of Cardiovascular Electrophysiology. https://doi.org/10.1111/jce.16309

Vancouver

Gidney B, Della Rocca DG, Horton R, Hoffman J, Valderrábano M, Natale A, et al. Step‐by‐step recommendations utilizing four‐dimensional intracardiac echocardiography in left atrial appendage procedures. Journal of Cardiovascular Electrophysiology. 2024. doi:10.1111/jce.16309

BibTeX
@article{Gidney2024,
  author = {Gidney, Brett and Della Rocca, Domenico G and Horton, Rodney and Hoffman, Joel and Valderrábano, Miguel and Natale, Andrea and Garg, Jalaj and Bhardwaj, Rahul and Doshi, Shephal},
  title = {Step‐by‐step recommendations utilizing four‐dimensional intracardiac echocardiography in left atrial appendage procedures},
  journal = {Journal of Cardiovascular Electrophysiology},
  year = {2024},
  doi = {10.1111/jce.16309}
}
Start for free →