EUVIMEDEUVIMED entdecken
Crossref

Comparison of novel intrinsic versus conventional antitachycardia pacing for ventricular tachycardia among implantable cardioverter‐defibrillator recipients

Satoshi Yanagisawa iD, Yasuya Inden iD, Yuki Sato, Ryo Watanabe, Takayuki Goto, Shun Kondo, Masaya Tachi, Tomoya Iwawaki, Ryota Yamauchi, Kei Hiramatsu, Masafumi Shimojo, Yukiomi Tsuji und 2 weitere

Journal of Cardiovascular Electrophysiology · 2024

DOI: 10.1111/jce.16232 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Cardiovascular Electrophysiology, 2024. Verfasst von Satoshi Yanagisawa und 13 weiteren Autor:innen. Beteiligte Einrichtung: Department of Advanced Cardiovascular Therapeutics, Nagoya University Graduate School of Medicine, Nagoya, Japan. Hauptthemen laut MEDLINE: Defibrillators, Implantable, Tachycardia, Ventricular. Die Arbeit wurde bisher 7-mal zitiert (Crossref) und nennt 18 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Introduction

Intrinsic antitachycardia pacing (iATP) is a novel automated antitachycardia pacing (ATP) that provides individual treatment to terminate ventricular tachycardia (VT). However, the clinical efficacy of iATP in comparison with conventional ATP is unknown. We aim to compare the termination rate of VT between iATP and conventional ATP in patients with implantable cardioverter‐defibrillators using a unique setting of different sequential orders of both ATP algorisms.

Methods

Patients with the iATP algorithm were assigned to iATP‐first and conventional ATP‐first groups sequentially. In the iATP‐first group, a maximum of seven iATP sequences were delivered, followed by conventional burst and ramp pacing. In contrast, in the conventional ATP‐first group, two bursts and ramp pacing were initially programmed, followed by iATP sequences. We compared the success rates of VT termination in the first and secondary programmed ATP zones between the two groups.

Results

Fifty‐eight and 56 patients were enrolled in the iATP‐first and conventional ATP‐first groups, and 67 and 44 VTs were analyzed in each group, respectively. At the first single ATP therapy, success rates were 64% and 70% in the iATP and conventional groups, respectively. At the end of the first iATP treatment zone, the success rate increased from 64% to 85%. Moreover, secondary iATP therapy following the failure of conventional ATPs increased the success rate from 80% to 93%. There was a significant benefit of alternative iATP for VT termination compared to secondary conventional ATP (100% vs. 33%, p = .028). Conclusions iATP may be beneficial as a secondary therapy after failure of conventional ATP to terminate VT.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Defibrillators, ImplantableTachycardia, VentricularHumansTreatment OutcomeCardiac Pacing, ArtificialAdenosine Triphosphate

Stichwörter der Autor:innen

automated antitachycardia pacingburst pacingcobalt XTimplantable cardioverter‐defibrillatorintrinsic antitachycardia pacingramp pacingventricular tachycardia

Substanzen

Adenosine Triphosphate

Autor:innen und Institutionen

  • Department of Advanced Cardiovascular Therapeutics, Nagoya University Graduate School of Medicine, Nagoya, Japan.
  • Department of Cardiology, Nagoya University Graduate School of Medicine, Nagoya, Japan.
  • Department of Clinical Engineering, Nagoya University Hospital, Nagoya, Japan.

ORCID-Profile: Satoshi Yanagisawa, Yasuya Inden

Zitieren

APA

Yanagisawa, S., Inden, Y., Sato, Y., Watanabe, R., Goto, T., Kondo, S., Tachi, M., Iwawaki, T., Yamauchi, R., Hiramatsu, K., Shimojo, M., Tsuji, Y., Shibata, R., & Murohara, T. (2024). Comparison of novel intrinsic versus conventional antitachycardia pacing for ventricular tachycardia among implantable cardioverter‐defibrillator recipients. Journal of Cardiovascular Electrophysiology. https://doi.org/10.1111/jce.16232

Vancouver

Yanagisawa S, Inden Y, Sato Y, Watanabe R, Goto T, Kondo S, et al. Comparison of novel intrinsic versus conventional antitachycardia pacing for ventricular tachycardia among implantable cardioverter‐defibrillator recipients. Journal of Cardiovascular Electrophysiology. 2024. doi:10.1111/jce.16232

BibTeX
@article{Yanagisawa2024,
  author = {Yanagisawa, Satoshi and Inden, Yasuya and Sato, Yuki and Watanabe, Ryo and Goto, Takayuki and Kondo, Shun and Tachi, Masaya and Iwawaki, Tomoya and Yamauchi, Ryota and Hiramatsu, Kei and Shimojo, Masafumi and Tsuji, Yukiomi and Shibata, Rei and Murohara, Toyoaki},
  title = {Comparison of novel intrinsic versus conventional antitachycardia pacing for ventricular tachycardia among implantable cardioverter‐defibrillator recipients},
  journal = {Journal of Cardiovascular Electrophysiology},
  year = {2024},
  doi = {10.1111/jce.16232}
}
Kostenlos starten →