EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Optimization of anti-tachycardia pacing efficacy through scar-specific delivery and minimization of re-initiation: a virtual study on a cohort of infarcted porcine hearts

Shuang Qian iD, Adam Connolly, Caroline Mendonca-Costa, Fernando Campos iD, Cristobal Rodero iD, John Whitaker iD, Christopher A Rinaldi iD, Martin J Bishop iD

EP Europace · 2023

DOI: 10.1093/europace/euac165 ↗

Kurz gefasst

Fachartikel in der Zeitschrift EP Europace, 2023. Verfasst von Shuang Qian und 7 weiteren Autor:innen. Beteiligte Einrichtung: Department of Biomedical Engineering, School of Imaging Sciences and Biomedical Engineering, Kings College London, London, UK. Hauptthemen laut MEDLINE: Tachycardia, Ventricular, Defibrillators, Implantable. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 20 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Medical Research Council, British Heart Foundation, NIHR Biomedical Research Centre.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Aims

Anti-tachycardia pacing (ATP) is a reliable electrotherapy to painlessly terminate ventricular tachycardia (VT). However, ATP is often ineffective, particularly for fast VTs. The efficacy may be enhanced by optimized delivery closer to the re-entrant circuit driving the VT. This study aims to compare ATP efficacy for different delivery locations with respect to the re-entrant circuit, and further optimize ATP by minimizing failure through re-initiation. Methods and results Seventy-three sustained VTs were induced in a cohort of seven infarcted porcine ventricular computational models, largely dominated by a single re-entrant pathway. The efficacy of burst ATP delivered from three locations proximal to the re-entrant circuit (septum) and three distal locations (lateral/posterior left ventricle) was compared. Re-initiation episodes were used to develop an algorithm utilizing correlations between successive sensed electrogram morphologies to automatically truncate ATP pulse delivery. Anti-tachycardia pacing was more efficacious at terminating slow compared with fast VTs (65 vs. 46%, P = 0.000039). A separate analysis of slow VTs showed that the efficacy was significantly higher when delivered from distal compared with proximal locations (distal 72%, proximal 59%), being reversed for fast VTs (distal 41%, proximal 51%). Application of our early termination detection algorithm (ETDA) accurately detected VT termination in 79% of re-initiated cases, improving the overall efficacy for proximal delivery with delivery inside the critical isthmus (CI) itself being overall most effective.

Conclusion

Anti-tachycardia pacing delivery proximal to the re-entrant circuit is more effective at terminating fast VTs, but less so slow VTs, due to frequent re-initiation. Attenuating re-initiation, through ETDA, increases the efficacy of delivery within the CI for all VTs.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Tachycardia, VentricularDefibrillators, ImplantableSwineAnimalsCicatrixCardiac Pacing, ArtificialHeart VentriclesAdenosine Triphosphate

Stichwörter der Autor:innen

Cardiac resynchronization therapyImplantable cardioverter defibrillatorPatient-specific modellingVentricular tachycardiaȃAnti-tachycardia pacing

Substanzen

Adenosine Triphosphate

Autor:innen und Institutionen

  • Department of Biomedical Engineering, School of Imaging Sciences and Biomedical Engineering, Kings College London, London, UK.
  • Invicro, London, UK.
  • Department of Cardiology, Guy's and St Thomas' Hospital, London, UK.

ORCID-Profile: Shuang Qian, Fernando Campos, Cristobal Rodero, John Whitaker, Christopher A Rinaldi, Martin J Bishop

Förderung

  • Medical Research Council
  • British Heart Foundation
  • NIHR Biomedical Research Centre
  • NHS Foundation Trust
  • Welcome EPSRC Centre for Medical Engineering
  • King’s College London
  • Welcome Trust
  • European Union’s Horizon 2020 Research

Zitieren

APA

Qian, S., Connolly, A., Mendonca-Costa, C., Campos, F., Rodero, C., Whitaker, J., Rinaldi, C. A., & Bishop, M. J. (2023). Optimization of anti-tachycardia pacing efficacy through scar-specific delivery and minimization of re-initiation: a virtual study on a cohort of infarcted porcine hearts. EP Europace. https://doi.org/10.1093/europace/euac165

Vancouver

Qian S, Connolly A, Mendonca-Costa C, Campos F, Rodero C, Whitaker J, et al. Optimization of anti-tachycardia pacing efficacy through scar-specific delivery and minimization of re-initiation: a virtual study on a cohort of infarcted porcine hearts. EP Europace. 2023. doi:10.1093/europace/euac165

BibTeX
@article{Qian2023,
  author = {Qian, Shuang and Connolly, Adam and Mendonca-Costa, Caroline and Campos, Fernando and Rodero, Cristobal and Whitaker, John and Rinaldi, Christopher A and Bishop, Martin J},
  title = {Optimization of anti-tachycardia pacing efficacy through scar-specific delivery and minimization of re-initiation: a virtual study on a cohort of infarcted porcine hearts},
  journal = {EP Europace},
  year = {2023},
  doi = {10.1093/europace/euac165}
}
Kostenlos starten →