EUVIMEDEUVIMED entdecken
Crossref

Cardiac computed tomography angiography for assessment of endothelial insufficiency of left atrial appendage disc‐like occluder

Zhiyong Duan, Genling Shi, Bin Wang, Yongjian Shen, Mengshi Xie, Zhenzhou Zhang, Xixi Dai, Weifeng Yao, Yunfei Liu, Hongyu Shi iD

Journal of Cardiovascular Electrophysiology · 2024

DOI: 10.1111/jce.16176 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Cardiovascular Electrophysiology, 2024. Verfasst von Zhiyong Duan und 9 weiteren Autor:innen. Beteiligte Einrichtung: Departments of Cardiology of Zhongshan Hospital Wusong Branch, Fudan University, Shanghai, China. Hauptthemen laut MEDLINE: Atrial Appendage, Atrial Fibrillation. Die Arbeit nennt 10 Literaturangaben. Gefördert von: Shanghai Baoshan District Medical and Health Project, Natural Science Foundation of Shanghai, Key Project of the Science and Technology Committee of Baoshan District Shanghai.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Introduction

This study was performed to explore the diagnostic value of cardiac computed tomography angiography (CCTA) for endothelial insufficiency (EIS) of a left atrial appendage (LAA) disc‐like occluder.

Methods

Fifty‐nine patients with nonvalvular atrial fibrillation who underwent placement of an LAA disc‐like occluder (LAmbre; Lifetech Scientific) in our hospital were retrospectively analyzed. Patients who were found to have contrast agent entering the LAA at the 3‐month postoperative CCTA examination underwent Hounsfield unit (HU) measurement of the LAA and construction of a three‐dimensional (3D) model of the device for preliminary discernment between peri‐device leakage (PDL) and EIS. These patients were then further examined by transesophageal echocardiography (TEE) to check for concordance with the computed tomography (CT) findings. According to the CT and TEE results, all patients were divided into the PDL group, total endothelialization group, and EIS group. The endothelial conditions and other implantation‐related results were also tracked at the 6‐month follow‐up.

Results

All 59 patients underwent successful implantation of the LAmbre LAA closure device with no severe adverse events during the procedure. Thirty‐five patients were found to have contrast agent entering the LAA at the 3‐month postoperative CCTA follow‐up. Based on the CT HU measurement and the 3D construction analysis results, these 35 patients were divided into the PDL group (19 patients) and the EIS group (16 patients). In the PDL group, the contrast agent infiltrated from the shoulder along the periphery of the occluder on two‐dimensional (2D) CT images, and the 3D model showed a gap between the LAA and the device cover. However, the CCTA images of the other 16 patients in the EIS group showed that the contrast agent in the occluder on the 2D CTA images and 3D construction model confirmed the absence of a gap between the LAA and the device cover. TEE confirmed all of the CT results. The 6‐month follow‐up results showed that 14 of 19 patients in the EIS group achieved total endothelialization, whereas this number in the PDL group was only five of 19 patients.

Conclusion

CCTA can replace TEE for examination of the endothelialization status, and patients with EIS have a higher chance of endothelialization than patients with PDL.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Atrial AppendageAtrial FibrillationHumansComputed Tomography AngiographyRetrospective StudiesContrast MediaTomography, X-Ray ComputedEchocardiography, TransesophagealCardiac CatheterizationTreatment Outcome

Stichwörter der Autor:innen

cardiac computed tomography angiographydisc-like occluderendothelial insufficiencyleft atrial appendage occlusionperi-device leakage

Substanzen

Contrast Media

Autor:innen und Institutionen

  • Departments of Cardiology of Zhongshan Hospital Wusong Branch, Fudan University, Shanghai, China.
  • Departments of Radiology Zhongshan Hospital Wusong Branch, Fudan University, Shanghai, China.
  • Equipment Division of Zhongshan Hospital Wusong Branch, Fudan University, Shanghai, China.

ORCID-Profile: Hongyu Shi

Förderung

  • Shanghai Baoshan District Medical and Health Project
  • Natural Science Foundation of Shanghai
  • Key Project of the Science and Technology Committee of Baoshan District Shanghai

Zitieren

APA

Duan, Z., Shi, G., Wang, B., Shen, Y., Xie, M., Zhang, Z., Dai, X., Yao, W., Liu, Y., & Shi, H. (2024). Cardiac computed tomography angiography for assessment of endothelial insufficiency of left atrial appendage disc‐like occluder. Journal of Cardiovascular Electrophysiology. https://doi.org/10.1111/jce.16176

Vancouver

Duan Z, Shi G, Wang B, Shen Y, Xie M, Zhang Z, et al. Cardiac computed tomography angiography for assessment of endothelial insufficiency of left atrial appendage disc‐like occluder. Journal of Cardiovascular Electrophysiology. 2024. doi:10.1111/jce.16176

BibTeX
@article{Duan2024,
  author = {Duan, Zhiyong and Shi, Genling and Wang, Bin and Shen, Yongjian and Xie, Mengshi and Zhang, Zhenzhou and Dai, Xixi and Yao, Weifeng and Liu, Yunfei and Shi, Hongyu},
  title = {Cardiac computed tomography angiography for assessment of endothelial insufficiency of left atrial appendage disc‐like occluder},
  journal = {Journal of Cardiovascular Electrophysiology},
  year = {2024},
  doi = {10.1111/jce.16176}
}
Kostenlos starten →