Left atrial strain is a good predictor of atrio‐ventricular synchrony in leadless pacemaker pacing
Journal of Cardiovascular Electrophysiology · 2024-01 · 35 (1) · 155-161
DOI: 10.1111/jce.16140 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Cardiovascular Electrophysiology, online erschienen am 27.11.2023. Verfasst von Federica Troisi und 7 weiteren Autor:innen. Beteiligte Einrichtung: Cardiology Department, Regional General Hospital "F. Miulli", Bari, Italy. Hauptthemen laut MEDLINE: Heart Atria, Pacemaker, Artificial. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 20 Literaturangaben.
Abstract (Originalsprache)
Introduction
The importance of atrio‐ventricular synchrony pacing in sinus rhythm patients is known. To identify patients in whom leadless pacemakers are able to guarantee this atrio‐ventricular synchrony, we explored correlations among echocardiographic measures of left atrial (LA) size and function (doppler parameter and strain) with A4 amplitude in patients implanted with new generation Micra‐AV device.
Methods
After implantation with Micra‐AV system, patients underwent device interrogation to evaluate AV synchrony based on the sensing of atrial mechanics and echocardiographic exam to assess LA morphology and LA function.
Results
In the 21 studied patients (14 males, 72 ± 13 years), the A4 wave amplitude values inversely correlated with LA antero‐posterior diameter, LA volume, LA contraction strain and LA conduit strain, while they were positively related with LA reservoir strain.
Discussion
Our results indicate a statistically significant relationship between morphological echocardiographic LA parameters and atrial contraction signal (A4), detected by leadless pacemakers and used to synchronize ventricular pacing with the atrium. Instantaneous LA function assessment obtained with LA strain provides incremental information over morphological parameters. LA strain evaluates atrial myocardial deformation during the whole cardiac cycle. We found higher value of A4 in patients that have grater absolute value of LAsr, LAscd and LAsct, that are simple and measurable parameters of LA functional capacity.
Conclusion
Preimplant echocardiographic evaluation of the atrial contractility may be useful in predicting adequate A4 sensing and consequently a good atrio‐ventricular synchrony pacing. Echocardiography LA strain study seems promising in Micra‐AV patient selection.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Cardiology Department, Regional General Hospital "F. Miulli", Bari, Italy.
- Interdisciplinary Department of Medicine, Cardiology Unit Polyclinic of Bari, University of Bari "Aldo Moro", Bari, Italy.
ORCID-Profile: Federica Troisi, Vincenzo E Santobuono, Andrea I Guaricci
Zitieren
APA
Troisi, F., Caccavo, V. P., Santobuono, V. E., Sgarra, L., Carella, M. C., Basile, P., Guaricci, A. I., & Grimaldi, M. (2024). Left atrial strain is a good predictor of atrio‐ventricular synchrony in leadless pacemaker pacing. Journal of Cardiovascular Electrophysiology, 35(1), 155-161. https://doi.org/10.1111/jce.16140
Vancouver
Troisi F, Caccavo VP, Santobuono VE, Sgarra L, Carella MC, Basile P, et al. Left atrial strain is a good predictor of atrio‐ventricular synchrony in leadless pacemaker pacing. Journal of Cardiovascular Electrophysiology. 2024;35(1):155-161. doi:10.1111/jce.16140
BibTeX
@article{Troisi2024,
author = {Troisi, Federica and Caccavo, Vincenzo P and Santobuono, Vincenzo E and Sgarra, Luca and Carella, Maria C and Basile, Paolo and Guaricci, Andrea I and Grimaldi, Massimo},
title = {Left atrial strain is a good predictor of atrio‐ventricular synchrony in leadless pacemaker pacing},
journal = {Journal of Cardiovascular Electrophysiology},
year = {2024},
volume = {35},
number = {1},
pages = {155--161},
doi = {10.1111/jce.16140}
}
EUVIMED