Standardized Temporary Atrial Epicardial Wire Locations Lead to Enhanced Atrial Signal Identification
Journal of Intensive Care Medicine · 2025
DOI: 10.1177/08850666241279229 ↗Kurz gefasst
Multizentrische Studie in der Zeitschrift Journal of Intensive Care Medicine, 2025. Verfasst von Nir Atlas und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Pediatrics, Ward Family Heart Center, Children's Mercy Kansas City, University of Missouri-Kansas City School of Medicine, USA. Hauptthemen laut MEDLINE: Heart Atria, Electrocardiography, Cardiac Surgical Procedures, Arrhythmias, Cardiac. Die Arbeit nennt 20 Literaturangaben.
Abstract (Originalsprache)
Background
Arrhythmias, common after pediatric cardiac surgery, are associated with increased morbidity and mortality. Atrial epicardial wires (AEW) improve diagnostic accuracy but have variable pacing and sensing properties based on their location. Even so, there are no longitudinal prospective pediatric studies examining ideal placement of AEW.
Methods
This multicenter study compared atrial amplitudes, pacing sensitivities and thresholds via AEW placed at Bachmann's Bundle (BB) and the interatrial groove near the right pulmonary veins (IGRPV) versus the surgeons’ standard locations. An AtriAmp system was used to obtain an atrial ECG to calculate atrial and ventricular amplitude from atrial electrograms on the bedside monitor. Sensitivities and thresholds via a temporary pacemaker were documented. ANOVA tests with repeated measures and post-hoc pairwise comparisons were performed to compare variables within the first 24-h postoperative hours. Mixed effects linear regression models were employed to examine daily trends.
Results
In the first 24-h following cardiac surgery, AEW at BB and IGRPV showed significantly larger atrial amplitudes than the surgeons’ standard locations. In addition, there was a negative trend in atrial ECG amplitude in all AEW from postoperative days 0 to 1; however, subsequent days showed a positive mean change in atrial amplitude with largest increase seen at BB. Atrial sensing as measured by the temporary pacemaker had statistically greater atrial signal amplitude from the BB-IGRPV set in both polarities (ie, with the BB as the – or + electrode pair) as compared to the surgeons’ standard locations. No difference in atrial thresholds (mA) were noted in the immediate postoperative period or over time, with a relatively low atrial threshold at all sites.
Conclusion
Standardization of AEW at Bachmann's Bundle can yield largest atrial amplitudes by atrial ECG and highest atrial sensing parameters without compromising atrial thresholds.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Pediatrics, Ward Family Heart Center, Children's Mercy Kansas City, University of Missouri-Kansas City School of Medicine, USA.
- Pediatric Cardiology, The University of Wisconsin - Madison, School of Medicine and Public Health, USA.
- Cardiothoracic Surgery, The University of Wisconsin - Madison, School of Medicine and Public Health, USA.
- Department of Surgery, Ward Family Heart Center, Children's Mercy Kansas City, University of Missouri-Kansas City School of Medicine, USA.
- Department of Pediatric Electrophysiology, Ward Family Heart Center, Children's Mercy Kansas City, USA.
ORCID-Profile: Nir Atlas, Nicholas H Von Bergen
Zitieren
APA
Atlas, N., Zhang, X., Torgeson, J. N., Hermsen, J., Gibson, W. J., Harmon, A. M., & Von Bergen, N. H. (2025). Standardized Temporary Atrial Epicardial Wire Locations Lead to Enhanced Atrial Signal Identification. Journal of Intensive Care Medicine. https://doi.org/10.1177/08850666241279229
Vancouver
Atlas N, Zhang X, Torgeson JN, Hermsen J, Gibson WJ, Harmon AM, et al. Standardized Temporary Atrial Epicardial Wire Locations Lead to Enhanced Atrial Signal Identification. Journal of Intensive Care Medicine. 2025. doi:10.1177/08850666241279229
BibTeX
@article{Atlas2025,
author = {Atlas, Nir and Zhang, Xiao and Torgeson, Jenna N and Hermsen, Joshua and Gibson, William J and Harmon, Adam M and Von Bergen, Nicholas H},
title = {Standardized Temporary Atrial Epicardial Wire Locations Lead to Enhanced Atrial Signal Identification},
journal = {Journal of Intensive Care Medicine},
year = {2025},
doi = {10.1177/08850666241279229}
}
EUVIMED