Fachartikel in der Zeitschrift Journal of Cardiovascular Electrophysiology, 2024. Verfasst von Yu Liao und 6 weiteren Autor:innen. Beteiligte Einrichtung: Division of Cardiology, Banner - University Medical Center Phoenix, University of Arizona, College of Medicine, Phoenix, Arizona, USA. Hauptthemen laut MEDLINE: Atrial Fibrillation, Cryosurgery, Catheter Ablation, Pulmonary Veins. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 16 Literaturangaben.
Abstract (Originalsprache)
Introduction
The circular catheter compatible with current cryoballoon system for atrial fibrillation (AF) ablation is exclusively sensed by impedance‐based electro‐anatomical mapping (EAM) system, limiting the accuracy of maps. We aim to investigate the feasibility and safety of a magnetic‐based circular mapping catheter for AF ablation with cryoballoon.
Methods
Nineteen consecutive patients who underwent pulmonary vein isolation (PVI) with cryoballoon for paroxysmal or persistent AF were included. EAMs of left atrium (LA) created by the LASSOSTAR™NAV catheter (Lassostar map) before and after PVI were compared to that generated by a high‐density mapping catheter (Pentaray map) from different aspects including structural similarity, PV angle, LA posterior wall (LAPW) and low voltage areas (LVAs), and the amplitude of far field electrograms (FFEs) recorded by catheters.
Results
All patients had successful PVI without major complications. With similar mapping time and density, the LA volume calculated from the Pentaray map and Lassostar map were comparable. There were no significant differences in PV angle of all PVs and PW area (16.8 ± 3.2 vs. 17.1 ± 2.8, p = .516) between Pentaray map and Lassostar map. High structural similarity score was observed between two maps (0.783 in RAO/LAO view and 0.791 in PA view). Lassostar map detected lesser but not statistically significant extension of LVA (13.9% vs. 18.3%, p = .07). Amplitude of FFE was larger at the right superior PV on Lassostar map (0.21 ± 0.16 vs. 0.14 ± 0.11 mV, p = .041) compared to that on the Pentaray map.
Conclusion
In our initial experience, PVI with cryoballoon and magnetic‐based circular LASSOSTAR™NAV catheter was safe and effective based on the accurate LA geometry it created.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Division of Cardiology, Banner - University Medical Center Phoenix, University of Arizona, College of Medicine, Phoenix, Arizona, USA.
- Department of Internal Medicine, Division of Cardiology, National Cheng Kung University Hospital, Tainan, Taiwan.
ORCID-Profile: Rong Bai, Dalise Yi Shatz, Wilber Su
Zitieren
APA
Liao, Y., Bai, R., Shatz, D. Y., Weiss, J. P., Zawaneh, M., Tung, R., & Su, W. (2024). Initial clinical experience of atrial fibrillation ablation guided by a cryoballoon‐compatible, magnetic‐based circular catheter. Journal of Cardiovascular Electrophysiology. https://doi.org/10.1111/jce.16124
Vancouver
Liao Y, Bai R, Shatz DY, Weiss JP, Zawaneh M, Tung R, et al. Initial clinical experience of atrial fibrillation ablation guided by a cryoballoon‐compatible, magnetic‐based circular catheter. Journal of Cardiovascular Electrophysiology. 2024. doi:10.1111/jce.16124
BibTeX
@article{Liao2024,
author = {Liao, Yu and Bai, Rong and Shatz, Dalise Yi and Weiss, J Peter and Zawaneh, Michael and Tung, Roderick and Su, Wilber},
title = {Initial clinical experience of atrial fibrillation ablation guided by a cryoballoon‐compatible, magnetic‐based circular catheter},
journal = {Journal of Cardiovascular Electrophysiology},
year = {2024},
doi = {10.1111/jce.16124}
}
EUVIMED