EUVIMEDOpdag EUVIMED
Randomisierte kontrollierte Studie

Effect of Repositioning Frequency on Bilirubin Levels and Comfort in Neonates Receiving Phototherapy: A Randomized Controlled Trial

Sevinc Akkoyun iD, Sibel Kücükoglu iD, Fatma Tas Arslan iD

International Journal of Nursing Practice · 2026

DOI: 10.1111/ijn.70187 ↗

At a glance

Randomisierte kontrollierte Studie in International Journal of Nursing Practice, 2026. Written by Sevinc Akkoyun and 2 co-authors. Institution: Vocational School of Health Services, Selcuk University, Konya, Türkiye. Major MEDLINE topics: Phototherapy, Bilirubin, Patient Positioning. 27 references.

AbstractSubjectsBibliografiske oplysningerCiteRelated studies

Abstract (original language)

Aim

This study was conducted to determine the effects of the frequency of repositioning during phototherapy on neonates' bilirubin levels and comfort.

Methods

This was a single‐centre, three‐arm, pretest‐posttest parallel‐group randomized controlled trial conducted in a neonatal intensive care unit. Participants were randomly assigned to one of three groups: the supine position group ( n = 20), the hourly position change group ( n = 20), and the control group (2‐h position change) ( n = 20). The bilirubin levels and comfort levels of the neonates were evaluated.

Results

It was determined that there was no difference between the groups in terms of baseline total bilirubin (TB) levels, TB levels at the end of 24 h, and time neonate was not under phototherapy ( p > 0.05). The effect of the interventions on the comfort score was found to be statistically significant ( p < 0.001). The mean levels were 10.28 ± 0.92 in the supine group, 10.63 ± 0.81 in the hourly position change group, and 7.14 ± 0.28 in the control group. The effect of group, time, group and time on the comfort score was also statistically significant ( p < 0.001).

Conclusions

The results obtained in this study show that there is no statistically significant difference in bilirubin levels between the different positional groups during phototherapy. Neonates in the control group were found to have higher comfort compared to the other two groups.

Subjects

MeSH terms (MEDLINE)

PhototherapyBilirubinPatient PositioningHumansInfant, NewbornFemaleMaleIntensive Care Units, Neonatal

Author keywords

bilirubincomfortneonatesnursingphototherapypositioning

Substances

Bilirubin

Authors and institutions

  • Vocational School of Health Services, Selcuk University, Konya, Türkiye.
  • Faculty of Nursing, Selcuk University, Konya, Türkiye.

ORCID profiles: Sevinc Akkoyun, Sibel Kücükoglu, Fatma Tas Arslan

Cite

APA

Akkoyun, S., Kücükoglu, S., & Tas Arslan, F. (2026). Effect of Repositioning Frequency on Bilirubin Levels and Comfort in Neonates Receiving Phototherapy: A Randomized Controlled Trial. International Journal of Nursing Practice. https://doi.org/10.1111/ijn.70187

Vancouver

Akkoyun S, Kücükoglu S, Tas Arslan F. Effect of Repositioning Frequency on Bilirubin Levels and Comfort in Neonates Receiving Phototherapy: A Randomized Controlled Trial. International Journal of Nursing Practice. 2026. doi:10.1111/ijn.70187

BibTeX
@article{Akkoyun2026,
  author = {Akkoyun, Sevinc and Kücükoglu, Sibel and Tas Arslan, Fatma},
  title = {Effect of Repositioning Frequency on Bilirubin Levels and Comfort in Neonates Receiving Phototherapy: A Randomized Controlled Trial},
  journal = {International Journal of Nursing Practice},
  year = {2026},
  doi = {10.1111/ijn.70187}
}
Start for free →