EUVIMEDOpdag EUVIMED
Crossref

Diagnostic Accuracy of Point‐of‐Care Ultrasound in Detecting Nasogastric Tube Placement in Emergency Patients

Kemal Yilmaz iD, Elif Günay İsmailoğlu iD, Funda Karbek Akarca iD

International Journal of Nursing Practice · 2025-12 · 31 (6)

DOI: 10.1111/ijn.70077 ↗

At a glance

Journal article in International Journal of Nursing Practice, published online on 2025-10-30. Written by Kemal Yilmaz and 2 co-authors. Institution: Department of Internal Medicine, Ege University Hospital, İzmir, Turkey. Major MEDLINE topics: Intubation, Gastrointestinal, Point-of-Care Systems. Cited 1 times so far (Crossref); 52 references.

AbstractSubjectsBibliografiske oplysningerCiteRelated studies

Abstract (original language)

Background

Point‐of‐care ultrasound (POCUS) is used to verify the position of the nasogastric tube as an alternative to conventional methods.

Aim

This study aims to determine the diagnostic accuracy of POCUS in detecting nasogastric tube placement in emergency patients.

Methods

This was a prospective diagnostic accuracy study conducted at an emergency department between August and November 2021. We included 72 consecutively recruited patients aged 18 years and older who were planned for nasogastric tube insertion. The index and reference tests were ultrasound and chest X‐ray, respectively. Nasogastric tube placement was detected by ultrasound and X‐ray methods in all patients. Sensitivity, specificity and predictive values were calculated.

Results

Seventy‐two patients (mean age: 69.49 ± 13.75, 55.6% male) were included. According to neck and gastric ultrasound, 58 nasogastric tubes (80.6%) could be detected. When POCUS was compared to X‐rays, 56 (84.9%) were true positive and two (33.3%) were false positive. Fourteen nasogastric tubes (19.4%) could not be detected. When POCUS was compared to X‐rays, four (66.7%) were true negative and 10 (15.1%) were false negative. A combination of neck and gastric ultrasound had a sensitivity of 84.84% (95% CI, 73.9%–92.49%), a specificity of 66.6% (95% CI, 22.28%–95.67%), a positive predictive value of 96.55% (95% CI, 89.99%–98.87%) and a negative predictive value of 28.57% (95% CI, 15.19%–47.19%). The percentage agreement was high (0.83%), and Gwet's AC1 statistic rated as moderate (AC1 = 0.46).

Conclusion

POCUS can be used as a diagnostic tool in detecting nasogastric tube placement in the stomach but should be confirmed with a chest X‐ray in patients with a negative ultrasound result.

Subjects

MeSH terms (MEDLINE)

Intubation, GastrointestinalPoint-of-Care SystemsHumansMaleFemaleUltrasonographyAgedProspective StudiesMiddle AgedEmergency Service, HospitalAged, 80 and overSensitivity and SpecificityAdult

Author keywords

X‐raydiagnostic accuracyemergency departmentnasogastric tubenurseultrasonography

Authors and institutions

  • Department of Internal Medicine, Ege University Hospital, İzmir, Turkey.
  • Faculty of Health Sciences, Department of Nursing, Izmir Bakircay University, İzmir, Turkey.
  • Faculty of Medicine, Department of Emergency Medicine, Ege University, İzmir, Turkey.

ORCID profiles: Kemal Yilmaz, Elif Günay İsmailoğlu, Funda Karbek Akarca

Cite

APA

Yilmaz, K., İsmailoğlu, E. G., & Akarca, F. K. (2025). Diagnostic Accuracy of Point‐of‐Care Ultrasound in Detecting Nasogastric Tube Placement in Emergency Patients. International Journal of Nursing Practice, 31(6). https://doi.org/10.1111/ijn.70077

Vancouver

Yilmaz K, İsmailoğlu EG, Akarca FK. Diagnostic Accuracy of Point‐of‐Care Ultrasound in Detecting Nasogastric Tube Placement in Emergency Patients. International Journal of Nursing Practice. 2025;31(6). doi:10.1111/ijn.70077

BibTeX
@article{Yilmaz2025,
  author = {Yilmaz, Kemal and İsmailoğlu, Elif Günay and Akarca, Funda Karbek},
  title = {Diagnostic Accuracy of Point‐of‐Care Ultrasound in Detecting Nasogastric Tube Placement in Emergency Patients},
  journal = {International Journal of Nursing Practice},
  year = {2025},
  volume = {31},
  number = {6},
  doi = {10.1111/ijn.70077}
}
Start for free →