Accuracy of 3‐dimensional surgical guide for endodontic microsurgery with a new design concept: A cadaver study
International Endodontic Journal · 2025-02 · 58 (2) · 295-304
DOI: 10.1111/iej.14161 ↗Kurz gefasst
Fachartikel in der Zeitschrift International Endodontic Journal, online erschienen am 04.11.2024. Verfasst von Se-Won Ha und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Conservative Dentistry and Oral Science Research Center, Microscope Center, Yonsei University College of Dentistry, Seoul, Korea. Hauptthemen laut MEDLINE: Microsurgery, Cadaver, Cone-Beam Computed Tomography, Imaging, Three-Dimensional. Die Arbeit wurde bisher 11-mal zitiert (Crossref) und nennt 22 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0). Gefördert von: National Research Foundation of Korea.
Abstract (Originalsprache)
Aim
Despite the high success rate of endodontic microsurgery (EMS), it is difficult to suggest EMS as a general treatment option considering the difficulty of the procedure. A surgical guide has been proposed to overcome this problem. This study aimed to evaluate the stability of the surgical guide of a new design concept, as well as the accuracy of root resection, and to introduce the manufacturing method of the newly designed surgical guide. Methodology The experiment was conducted on 59 roots (9 in the maxillary and 50 in the mandibular region) of adult human cadavers. The surgical guide was designed using CAD/CAM design software based on cone‐beam computed tomography (CBCT) images and optical scan files. Unlike conventional surgical guides, the surgical guide proposed herein was designed to act as a tooth‐bone‐supported removable appliance. Two different types of guides were prepared: the osteotomy guide (O guide) for separation of the cortical bone above the root tip with a trephine bur with an outer diameter of 6 mm and the root resection guide (R guide) for resection of the root tip with a trephine bur with an outer diameter of 4 mm. For stability evaluation, the guides were pressed at five predetermined locations after installation and checked for the presence of any movement. For accuracy evaluation, the length at which the root tip was cut was measured and examined by overlapping the preoperative and postoperative CBCT images.
Results
Of the 15 R guides, 14 were stably installed without mobility. For the R guide group, the root tip was resected with an average of 3.2 mm, showing better results than the no‐guide group with an average of 4.0 mm.
Conclusions
The newly designed surgical guide of this study can be applied more stably, enabling root resection to be performed more accurately and simply according to the preoperative plan than when performed without a guide.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Conservative Dentistry and Oral Science Research Center, Microscope Center, Yonsei University College of Dentistry, Seoul, Korea.
- Department of Conservative Dentistry, National Health Insurance Service Ilsan Hospital, Goyang, Korea.
- Division in Anatomy and Developmental Biology, Department of Oral Biology, Human Identification Research Institute, BK21 FOUR Project, Yonsei University College of Dentistry, Seoul, Korea.
ORCID-Profile: Sunil Kim, Minju Song, Euiseong Kim
Förderung
- National Research Foundation of Korea
Zitieren
APA
Ha, S. W., Choi, S. M., Kim, S., Song, M., Hu, K. S., & Kim, E. (2025). Accuracy of 3‐dimensional surgical guide for endodontic microsurgery with a new design concept: A cadaver study. International Endodontic Journal, 58(2), 295-304. https://doi.org/10.1111/iej.14161
Vancouver
Ha SW, Choi SM, Kim S, Song M, Hu KS, Kim E. Accuracy of 3‐dimensional surgical guide for endodontic microsurgery with a new design concept: A cadaver study. International Endodontic Journal. 2025;58(2):295-304. doi:10.1111/iej.14161
BibTeX
@article{Ha2025,
author = {Ha, Se-Won and Choi, Stephanie M and Kim, Sunil and Song, Minju and Hu, Kyung-Seok and Kim, Euiseong},
title = {Accuracy of 3‐dimensional surgical guide for endodontic microsurgery with a new design concept: A cadaver study},
journal = {International Endodontic Journal},
year = {2025},
volume = {58},
number = {2},
pages = {295--304},
doi = {10.1111/iej.14161}
}
EUVIMED