EUVIMEDEUVIMED entdecken
Crossref

Comparison of a Novel Static Computer-aided Surgical and Freehand Techniques for Osteotomy and Root-end Resection

Kyle Westbrook, Corey Rollor, Sara A Aldahmash, Guadalupe G Fay, Elias Rivera, Jeffery B Price, Ina Griffin, Patricia A Tordik, Frederico C Martinho

Journal of Endodontics · 2023

DOI: 10.1016/j.joen.2023.02.008 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Endodontics, 2023. Verfasst von Kyle Westbrook und 8 weiteren Autor:innen. Beteiligte Einrichtung: Division of Endodontics, Department of Advanced Oral Sciences and Therapeutics, University of Maryland, School of Dentistry, Baltimore, Maryland. Hauptthemen laut MEDLINE: Printing, Three-Dimensional, Surgery, Computer-Assisted. Die Arbeit wurde bisher 17-mal zitiert (Crossref) und nennt 29 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

INTRODUCTION: This study compared the accuracy and efficiency of a novel static computer-aided surgical technique using a 3-dimensional (3D)-printed surgical guide (3D-SG) with a fully guided drill protocol (3D-SG FG) to the freehand (FH) osteotomy and root-end resection (RER). METHODS: Forty-six roots from 2 cadaver heads were divided into 2 groups: 3D-SG FG (n = 23) and FH (n = 23). Cone-beam computed tomographic scans were taken preoperatively and postoperatively. The endodontic microsurgery was planned in Blue Sky Bio software, and the 3D-SG was designed and 3D printed. The osteotomy and RER were conducted using a guided twist drill diameter of 2 mm and an ascending tapered drill with diameters of 2.8/3.2, 3.2/3.6, 3.8/4.2, and 4.2 mm with respective guided drill guides. Two-dimensional and three-dimensional virtual deviations and angular deflection were calculated. Linear osteotomy measures and root resection angle were obtained. The osteotomy and RER time and the number of mishaps were recorded. RESULTS: Two-dimensional and three-dimensional accuracy deviations and angular deflection were lower in the 3D-SG FG protocol than in the FH technique (P < .05). The height, length, and depth of the osteotomy and root resection angle were less in the 3D-SG FG protocol than in the FH technique (P < .05). The osteotomy and RER time with the 3D-SG FG protocol were less than the FH method (P < .05). CONCLUSIONS: Within the limitations of this cadaver-based study using denuded maxillary and mandibular jaws, 3D-SG FG protocol showed higher accuracy than FH osteotomy and RER. Moreover, the 3D-SG FG drill protocol significantly reduced the surgical time.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Printing, Three-DimensionalSurgery, Computer-AssistedHumansOsteotomyMaxillaCone-Beam Computed TomographyCadaverComputersComputer-Aided Design

Stichwörter der Autor:innen

3-dimensional printingApical surgeryendodontic microsurgeryguided surgerysurgical guide

Autor:innen und Institutionen

  • Division of Endodontics, Department of Advanced Oral Sciences and Therapeutics, University of Maryland, School of Dentistry, Baltimore, Maryland.
  • Division of Endodontics, Department of Advanced Oral Sciences and Therapeutics, University of Maryland, School of Dentistry, Baltimore, Maryland; King Abdullah Bin Abdulaziz University Hospital, College of Dentistry, Pr…
  • Division of Prosthodontics, Department of Advanced Oral Sciences and Therapeutics, University of Maryland, School of Dentistry, Baltimore, Maryland.
  • Division of Prosthodontics, Department of Advanced Oral Sciences and Therapeutics, University of Maryland, School of Dentistry, Baltimore, Maryland; Private Practice, Stafford, Virginia.
  • Division of Oral Radiology, Department of Oncology and Diagnostic Sciences, University of Maryland, School of Dentistry, Baltimore, Maryland.
  • Division of Endodontics, Department of Advanced Oral Sciences and Therapeutics, University of Maryland, School of Dentistry, Baltimore, Maryland. Electronic address: fmartinho@umaryland.edu.

Zitieren

APA

Westbrook, K., Rollor, C., Aldahmash, S. A., Fay, G. G., Rivera, E., Price, J. B., Griffin, I., Tordik, P. A., & Martinho, F. C. (2023). Comparison of a Novel Static Computer-aided Surgical and Freehand Techniques for Osteotomy and Root-end Resection. Journal of Endodontics. https://doi.org/10.1016/j.joen.2023.02.008

Vancouver

Westbrook K, Rollor C, Aldahmash SA, Fay GG, Rivera E, Price JB, et al. Comparison of a Novel Static Computer-aided Surgical and Freehand Techniques for Osteotomy and Root-end Resection. Journal of Endodontics. 2023. doi:10.1016/j.joen.2023.02.008

BibTeX
@article{Westbrook2023,
  author = {Westbrook, Kyle and Rollor, Corey and Aldahmash, Sara A and Fay, Guadalupe G and Rivera, Elias and Price, Jeffery B and Griffin, Ina and Tordik, Patricia A and Martinho, Frederico C},
  title = {Comparison of a Novel Static Computer-aided Surgical and Freehand Techniques for Osteotomy and Root-end Resection},
  journal = {Journal of Endodontics},
  year = {2023},
  doi = {10.1016/j.joen.2023.02.008}
}
Kostenlos starten →