EUVIMEDEUVIMED entdecken
Crossref

Dentine thickness in maxillary fused molars depends on the fusion type: An ex vivo micro‐computed tomography study

Cangül Keskin iD, Defne Toplu, Ali Keleş iD

International Endodontic Journal · 2023

DOI: 10.1111/iej.13891 ↗

Kurz gefasst

Fachartikel in der Zeitschrift International Endodontic Journal, 2023. Verfasst von Cangül Keskin und 2 weiteren Autor:innen. Beteiligte Einrichtung: Department of Endodontics, Faculty of Dentistry, Ondokuz Mayis University, Samsun, Turkey. Hauptthemen laut MEDLINE: Tooth Root, Molar. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 30 Literaturangaben. Gefördert von: Samsun Ondokuz Mayis University Research Fund.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Aim

The present study aimed to determine and compare the dentine thickness around the root canals of maxillary molars with fusion using micro‐computed tomography (micro‐CT). Methodology A total of 120 fused maxillary molars having more than a single canal with distinct canal orifices near the cementoenamel junction were selected from a pool of extracted maxillary molars, which were scanned on a micro‐CT device (SkyScan 1172, Bruker‐microCT). The minimum dentine thickness around the root canals in furcal direction was measured using CTAn software (v.1.18.8 Bruker‐microCT) at each millimetre. The specimens were grouped according to their fusion type, and dentine thickness around the canals was compared. The data were statistically analysed using anova and post hoc Tukey–Kramer tests following an assessment of the normality of their distribution with the Kolmogorov–Smirnov test ( p < .05).

Results

Dentine thickness showed a statistically significant decrease at 2 mm apical to the orifice level irrespective of fusion type. The minimum dentine thickness values were detected around the second mesiobuccal canal as 0.30 mm at 6 mm below orifice. Dentine thickness around the mesiobuccal canal was significantly greater in fusion type 1 than those of types 2 and 3 ( p < .05), while those of distobuccal and palatal canals were significantly thinner in type 3 fusion compared with type 1 or 6 ( p Dentine thickness showed a statistically significant decrease at 2 mm apical to the orifice level irrespective of fusion type. The minimum dentine thickness values were detected around the second mesiobuccal canal as 0.30 mm at 6 mm below orifice. Dentine thickness around the mesiobuccal canal was significantly greater in fusion type 1 than those of types 2 and 3 ( Conclusion Minimum dentine thickness values at the danger zone of distobuccal and palatal canals change according to the fusion type in fused maxillary second molars.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Tooth RootMolarX-Ray MicrotomographyDental Pulp CavityDentinMaxilla

Stichwörter der Autor:innen

danger zonedentine thicknessendodonticsfusionmicrotomographyroot canal anatomy

Autor:innen und Institutionen

  • Department of Endodontics, Faculty of Dentistry, Ondokuz Mayis University, Samsun, Turkey.

ORCID-Profile: Cangül Keskin, Ali Keleş

Förderung

  • Samsun Ondokuz Mayis University Research Fund

Zitieren

APA

Keskin, C., Toplu, D., & Keleş, A. (2023). Dentine thickness in maxillary fused molars depends on the fusion type: An ex vivo micro‐computed tomography study. International Endodontic Journal. https://doi.org/10.1111/iej.13891

Vancouver

Keskin C, Toplu D, Keleş A. Dentine thickness in maxillary fused molars depends on the fusion type: An ex vivo micro‐computed tomography study. International Endodontic Journal. 2023. doi:10.1111/iej.13891

BibTeX
@article{Keskin2023,
  author = {Keskin, Cangül and Toplu, Defne and Keleş, Ali},
  title = {Dentine thickness in maxillary fused molars depends on the fusion type: An ex vivo micro‐computed tomography study},
  journal = {International Endodontic Journal},
  year = {2023},
  doi = {10.1111/iej.13891}
}
Kostenlos starten →